• 제목/요약/키워드: Indoor temperature control

검색결과 298건 처리시간 0.029초

중앙냉방시스템의 실시간 준최적제어 적용에 따른 실험적 연구 (Real Time Near Optimal Control Application Strategy of Central Cooling System)

  • 안병천;송재엽;주영덕;김진
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.470-477
    • /
    • 2008
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling control system.

실험 데이터를 사용한 자동차 $CO_2$ 냉방시스템의 제어 알고리즘 개발 (Development of Control Algorithms for a $CO_2$ Automotive Air Conditioner System by Using Experimental data)

  • 한도영;장경창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.681-686
    • /
    • 2006
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of $CO_2's$ unique propel-ties as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, dynamic models of a $CO_2$ air-conditioning system were developed by using experimental data. Control algorithms for a high-side pressure control and an indoor air temperature control were developed and analysed by using the dynamic simulation program of a $CO_2$ system.

  • PDF

컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구 (An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer)

  • 조진호;이대우
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

사물인터넷 기반 실내 환경 모니터링 및 자동제어 시스템 구현 (Implementation of Indoor Environment Monitoring and Automatic Control System based on Internet of Things)

  • 이상훈;김진엽;김수연
    • 한국산업정보학회논문지
    • /
    • 제21권6호
    • /
    • pp.71-80
    • /
    • 2016
  • 생활수준이 점차 높아짐에 따라 환경문제에 대한 국민들의 관심과 인식 수준도 증가하였다. 최근 들어 실내 활동시간이 증가함에 따라 환경에 대한 인식과 개선에 대한 방안이 요구되고 있다. 본 연구에서는 IoT 기반 기술을 이용하여 실시간으로 실내 환경에 대한 모니터링을 통해 환경정보를 수집하고 연동된 제어장치를 이용하여 실내 환경을 적정수준으로 유지하고 개선하는 시스템을 설계하고 개발하였다. 이는 기존의 수동적인 실내 환경개선 행위나 대규모 설비를 대신하여 가정이나 소규모 장소에서도 자동적인 실내 환경개선 시스템을 제공한다. 본 시스템은 공기 질과 CO2, 온도와 습도, 소음과 조도에 따른 상태분석과 함께 상대적 기준치를 적용하여 9가지의 상태에 따른 제어신호를 자동제어 모듈로 전송하여 실내 환경을 개선한다.

실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구 (A study of frequency control of an inverter heat pump for indoor air temperature adjustment)

  • 박윤철;민만기
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

평균피부온도 분석을 통한 수면시 쾌적 실내 온도조건에 관한 연구 (Study on Comfortable Room Temperature using Mean Skin Temperature analysis in Sleeping)

  • 김동규;정용현
    • 수산해양교육연구
    • /
    • 제19권2호
    • /
    • pp.161-167
    • /
    • 2007
  • It is necessary to control the room temperature for comfortable and deep sleep during a tropical night. We need to investigate thermal transport and parameter between human and environment for comfortable sleep. Therefore this study is performed to evaluate the comfortable room temperature based on the change of skin temperature under variations in thermal conditions and several reports. Five female subjects of 20~22 years with similar sleeping pattern were participated for the experiment. The subjects arrived in chamber at 9 pm and adapted to thermal circumstances during 2 hours. The sensors was sticked in body for skin temperatures. If subjects fall asleep in chamber, lights off and then sleep during 8 hours.As results, indoor temperature range for comfort sleep was $23.9{\sim}28.4^{\circ}C$ based on comfort mean skin temperature. But considering transition of time, minimum indoor temperature was $21.6^{\circ}C$, $22.9^{\circ}C$, $24.1^{\circ}C$, $23.9^{\circ}C$ and maximum indoor temperature was $28.2^{\circ}C$, $30.1^{\circ}C$.

열원 및 공조설비의 최적제어시스템 현장 적용성에 관한 연구 (A Study on the Application of the Optimal Control System for Heat Source and HVAC System)

  • 백승재;김진;안병천;송재엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1014-1019
    • /
    • 2009
  • The optimal control system for heat source and HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters are supply air temperature and chilled or hot water temperatures. The optimal control study has been implemented for biosafety laboratory by using TRNSYS simulation program in order to investigate energy performance for heat source and HVAC system.

  • PDF

자동차 $CO_2$ 냉방시스템의 고압과 실내온도의 효과적인 제어를 위한 지능알고리즘 (Intelligent Algorithms for the Effective Control of High-side Pressure and Indoor Air Temperature of a $CO_2$ Automotive Air Conditioner System)

  • 장경창;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.480-485
    • /
    • 2005
  • In the respect of the environmental protection viewpoint, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be newly developed, because properties of $CO_2$ are different compared with those of classical refrigerants. Especially, high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, intelligent control algorithms for a $CO_2$ system were developed ‘ These are a high-side pressure control algorithm and an indoor air temperature control algorithm. These algorithms were analysised by using dynamic models of a $CO_2$ system.

  • PDF

전통주택의 하절기 실내 온열감 평가에 관한 연구 (A Study on the Thermal Sensation Vote of the Traditional Housing in Summer)

  • 강상우;전지현;신용규;민병철;국찬
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.488-491
    • /
    • 2006
  • There is a principle of Korean Traditional Housing to be adapted for the nature using adaptable shapes to regional climate and easily available materials from the region then these environmentally friendly characteristics keep indoor environment from climate changes. These environmentally friendly characteristics to control indoor environment are very available for contemporary housing in that current issues, housing amenity and wellbeing, have basic goals same with what Korean Traditional Housing has. Therefore, this study begins to suggest fundamental data on indoor thermal environment control elements of Korean Traditional Housing to adapt those into contemporary housing through measurement of indoor thermal environment elements and evaluation on thermal sensation vote for Korean traditional housing. There was 24 hours measurement for indoor and outdoor thermal environmental elements to figure out competence to control indoor thermal environment of Korean Traditional Housing in summer. And subjective tests with 11 subjects was held in the morning, afternoon and night at intervals of 3${\sim}$4 hours to evaluate feeling and amenity for temperature and humidity of users.

  • PDF

수면시 바닥표면온도에 따른 적정 환기량에 관한 연구 (A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping)

  • 김동규;이성;김세환
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.