• Title/Summary/Keyword: Indoor setting temperature

Search Result 27, Processing Time 0.021 seconds

Experimental Study on the Operating Characteristics of a Solar Hybrid Heat Pump System according to Indoor Setting Temperature (실내설정온도에 따른 태양열 하이브리드 열펌프 시스템 운전특성에 대한 실험적 연구)

  • Kim, Won-Seok;Cho, Hong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.50-58
    • /
    • 2010
  • Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature were carried out during spring and winter season. The system was consisted of a concentric evacuated tube solar collector, heat medium tank, heat storage tank, and heat pump. As a result, the heating load was increased by 21.1% when the indoor setting temperature rose by 2oC for the same ambient temperature. Besides, the spring season had good outdoor conditions compared to the winter season, therefore the heating load was reduced and heat gain by collector increased, relatively. In case of the winter season, the solar fraction was shown less than 10% because the heat losses of system and space increased considerably. The solar fraction decreased significantly as the indoor setting temperature increased.

An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling (가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구)

  • Kim, Dong-Hee;Yu, Ki-Hyung;Cho, Dong-Woo;Seo, Jung-Seok;Han, Sung-Phil
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

An Investigation of Environmental Performance on Shaft Box Type Balcony Adopted to Apartment Building (공동주택에 적용된 Shaft Box형 발코니의 환경성능 검토)

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.27-32
    • /
    • 2013
  • This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. The subject building was decided by analyzing various types of exiting apartments. Shaft box type balcony was devised by setting up shaft space at a part of balcony. Air flow and indoor air temperature were simulated, performance of shaft box type balcony was compared with existing types using VE computer simulation program. Research consequence can be summarized as follow: 1) In the case of existing types, the change of window opening rate has only a little effect on the improvement of indoor temperature. But, air flow rate increased two times in the case that changed opening rate 20% to 40% 2) In the case of existing types, the growth of air flow rate has little effect on the improvement of indoor temperature. But, shaft box type represented the remarkable effect on the improvement of indoor temperature as well as the growth of air flow rate.

Suitability of Setting Summer Indoor Temperature for Thermal Comfort (여름철 실내 쾌적온도 설정 기준의 적합성)

  • Shim, Huen Sup;Jeong, Woon Seon
    • The Korean Journal of Community Living Science
    • /
    • v.24 no.4
    • /
    • pp.583-589
    • /
    • 2013
  • This study was to provide the information for optimum utilization of the air-conditioning system in the human health and energy saving perspective. Subjects were 17 male and female college students(7 males and 10 females) with normal weight. They wore a short sleeved shirt, knee length trousers, socks, and underwear(0.4clo). They were asked to choose the preferred temperature from different environmental temperatures($28^{\circ}C$, $25^{\circ}C$). The physiological responses were measured and the subjective sensation was voted during the step changes of environmental temperature, starting at $28^{\circ}C$ to $25^{\circ}C$ with $1^{\circ}C$ decrease every 20 minutes. The preferred temperature was $25.9{\pm}0.4^{\circ}C$ for males and $26.9{\pm}0.2^{\circ}C$ for females at $28^{\circ}C$ and $24.8{\pm}0.6^{\circ}C$ for males and $25.6{\pm}0.1^{\circ}C$ for females at $25^{\circ}C$. The preferred temperature decreased about $1.3^{\circ}C$ while the environmental temperature changed $3^{\circ}C$. During the environmental step changes, mean skin temperature decreased more in females while the oxygen uptake and rectal temperature were kept constant for both males and females. We found the preferred temperature was affected by the exposed temperature and the thermal sensation in the condition. Subjects preferred a lower environmental temperature when they were exposed to a lower temperature with cooler sensation. Therefore, in the perspective of human health and energy saving, it is recommended to start setting the air-conditioning temperature higher than the preferred temperature.

A Study on the Change of Indoor Thermal Environment According to the location of Blinds (블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구)

  • Hwang, Deuk-Soo;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

Energy Saving Heating Control System Using the Power Line Communication Modem for a Valve Controller (밸브제어기용 전력선 통신 모뎀을 이용한 에너지 절약형 난방제어 시스템)

  • Kim, Myung-Ho;Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.123-127
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputted from the temperature sensor and the user to the valve controller. The valve controller receives these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, It is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.

Power Line Communication Heating Control System by LonWorks (LonWorks를 이용한 전력선 통신 난방제어 시스템)

  • Kim, Myung-Ho;Kim, Sun-Boo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1150-1155
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputed from the temperature sensor and the user to the valve controller. The valve controller recieves these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, it is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.

  • PDF

A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value (착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구)

  • Lee, Chul-Sung;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

A Study on Application of Shaft-box Type Double Skin to Apartment Building (공동주택에 대한 Shaft Box형 이중외피의 적용에 관한 연구)

  • Roh, Ji Wooung
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2013
  • The balcony of our apartment building consists of unique construction similar to double skin. It is announced broadly that double skin is very effective system in improvement of natural ventilation and indoor thermal environment, and outdoor sound protection. So, for the improvement of indoor climate and energy saving, many peoples studied about environmental performance of our balcony construction. This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. Proto-type was decided by analyzing various types of exiting apartments. Shaft box type balcony was created by setting up shaft space at a part of balcony. Air flow and contribution of air temperature were simulated, performance of shaft box type balcony was compared with existing balcony. Finally, we confirmed that shaft box type balcony has many possibility for improvement of indoor environment.