• 제목/요약/키워드: Indoor pollutants

검색결과 327건 처리시간 0.027초

서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성 (Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan)

  • 이태정;임효지;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

흡연이 흰쥐 복부 피지샘의 glycoconjugates에 미치는 영향에 대한 lectin 조직화학 (Lectin Histochemistry on the Effects of Smoking on Glycoconjugates of Rat Sebaceous Glands)

  • 조운복;정길남
    • 생명과학회지
    • /
    • 제18권11호
    • /
    • pp.1543-1550
    • /
    • 2008
  • 실내 환경 오염원으로 각종 암 발병과 관련이 있는 흡연이 피부 피지샘의 glycoconjugates에 미치는 영향을 lectin 조직화학으로 연구하였다. Sprague-Dawley계 수컷 흰쥐에 1일 1회 10분간 1일군, 2일군, 3일군 및 5일군으로 나누어 직?간접 흡연 방법으로 폭로시켜 피지샘 형태는 PAS 염색, 피지샘의 glycoconjugates 양상을 9종의 biotinylated lectin (DBA, SBA, PNA, BSL-1, WGA, RCA-1, UEA-1, Con A 및 LCA)으로 연구하였다. 대조군에 비해 흡연군에서는 피지샘꽈리의 크기 감소, 피지샘꽈리 상부의 파괴, 중앙부 피지세포의 공포화 및 미성숙 피지샘꽈리가 관찰되었다. 대조군에서 피지샘 glycoconjugates에는 염색성에 차이가 있으나 기저세포는 BSL-1, PNA 및 WGA에만 반응하고 BSL-1의 반응이 더 강하며, 피지세포는 PNA, WGA, Con A, BSL-1 및 SBA에만 반응하고 PNA 및 Con A의 반응이 더 강했다. 흡연군의 렉틴 반응에서 특이적인 변화가 관찰되었다. 흡연군의 피지샘 기저세포의 PNA 반응은 증가되었고, BSL-1는 감소되었다가 회복되었으며, WGA는 소실되었다. 피지세포의 Con A는 증가하였으나 PNA, BSL-1, WGA 및 SBA는 감소 또는 소실되었다. 대조군에 관찰되지 않던 흡연군의 미성숙 샘꽈리 PNA, on A 및 BSL-1이 반응하였으며 PNA 및 Con A의 반응이 더 현저하였다. 결론적으로 흡연은 피지샘의 형태 및 glycoconjugates 대사에 심한 영향을 미치는 것으로 사료된다.

대형 주물공정 용접작업장의 건강 위해인자 및 환기 개선 (Health Risk Factors and Ventilation Improvements in Welding Operation at Large-sized Casting Process)

  • 정종현;정유진;이상만;이정희;손병현;임현술
    • 청정기술
    • /
    • 제20권2호
    • /
    • pp.171-178
    • /
    • 2014
  • 이 연구에서는 대형 주물공정 용접작업장 근로자들의 건강보호 및 작업환경 개선을 위해 위해인자 조사 및 분석작업을 수행하였다. 또한, 대상 작업장의 작업환경을 개선하기 위해 측정 및 전산유체해석 모델링을 수행한 후 효과적인 환기방법을 제안하였다. 대형 주물공정 용접작업장 근로자들의 건강 위해인자를 조사한 결과, A사는 산화철분진, B사와 C사는 용접흄, D사는 용접 흄과 산화철분진이 주오염원인 것으로 확인되었다. 작업자 호흡영역에서의 흄 농도는 $0.05{\sim}4.37mg/m^3$이었고, 용접작업장 공기 중 흄 농도는 $0.13{\sim}7.54mg/m^3$이었다. 또한, 용접작업 시 최적의 환기방법을 제안하기 위해 측정 및 전산유체해석 모사를 수행한 결과, 배기공정의 경우에는 배기 덕트를 용접점에 근접시켜 국소배기를 실시하는 것이 효과적인 것으로 나타났다. 급기공정의 경우에는 개구부 끝 부분에서 급기를 하며 급기용 팬은 작업 공간 외부에 설치하는 것이 효과적일 것으로 나타났다. 향후 대형 주물공정 용접작업장의 터널형 반밀폐 공간에 대한 환기방법을 표준화한다면 주물산업 및 조선업 등에 종사하는 용접 근로자들의 건강보호 및 작업환경 개선에 매우 효과적일 것으로 판단된다.

수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구 (Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform)

  • 남궁형규;박세찬;김민해;김수연;권순박
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.443-449
    • /
    • 2017
  • 최근 국내 도시철도 지하역사에는 승강장 안전문의 설치로 인한 승강장의 급 배기 불균형이 일어나며, 이러한 불균형은 승강장 내 오염물질 축적과 환기부족에 의한 쾌적성 저하를 일으키는 원인이 된다. 본 연구에서는 시뮬레이션 유동해석 프로그램을 이용하여 지하역사 바닥배기 시스템의 최적화 설계를 하고, 제작된 바닥배기 시스템의 미세먼지 제거 성능을 실험으로 검증하였다. 바닥배기 시스템의 시뮬레이션 유동해석은 CFX 17.0 프로그램을 이용하였으며, HEEDS를 최적화 소프트웨어로 적용하였다. 3차에 걸쳐 이루어진 최적화 결과, 약 430 Pa의 차압과 61%의 미세먼지 제거 성능을 갖는 전체높이 1.78 m의 바닥배기 시스템이 도출되었다. 최적화 설계에 따라 실규모로 제작된 바닥배기 시스템을 이용하여 미세먼지 집진 성능 실험을 실시하였으며, 약 65%의 집진효율을 보임으로써 수치해석을 통해 도출된 최적설계 결과와 유사한 수준임을 검증하였다. 결과적으로 최적화 프로그램을 활용한 바닥배기 시스템의 설계가 급배기 불균형을 갖고 있는 지하역사 승강장에 적용 가능함을 확인하였으며, 설계된 바닥배기 시스템이 공간상의 제약으로 추가적인 배기설비 설치가 어려운 기존 지하 역사에서 배기개선 및 미세먼지 제거에 효과적으로 활용될 수 있을 것으로 판단된다.

아토피 피부염의 환경적 요인에 대한 동서의학적 고찰 (The Study on the Environmental Factors of Atopic Dermatitis in Oriental-Western Medicine)

  • 박승구;노현민;권소현;조은희;장현철;김호경;박히준;김원정;박민철
    • 한방안이비인후피부과학회지
    • /
    • 제31권1호
    • /
    • pp.52-70
    • /
    • 2018
  • Objectives : Atopic dermatitis(AD) and environmental factors are closely related, but there is lack of oriental medical examination. So we compared the relationship between AD and various environmental factors in Oriental medicine and Western medicine. Methods : We described the relationship between AD and environmental factors through the latest papers and a review of the oriental medicine literature. Results : The regional diversity of AD incidence implies a close relationship between climate factors and AD, and high altitude and low pH springs also have an effect on AD. Air pollutants from industrialization and urbanization aggravate AD. The increase in indoor residence time and the increase in room temperature and humidity have also increased the sensitization to allergens such as house dust mite. In oriental medicine, wind(風) is one of the environmental factors and is an inflammatory state due to external irritation. Wind-Humidity(風濕) refers to erythematous wetting dermatitis with itching and exudation, Wind-Fever(風熱) refers to acute inflammatory reaction with erythematous papules and plague, and Blood-Weakness(血虛) refers to aggravation and chronicization of inflammation due to persistence of skin barrier impairment. Conclusions : We examined the relationship between AD and various environmental factors. We also described the oriental medical viewpoints of the environmental factors in the occurrence of AD and skin barrier impairment.

다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구 (Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility)

  • 김태한;최부헌
    • 한국조경학회지
    • /
    • 제48권5호
    • /
    • pp.80-88
    • /
    • 2020
  • 2019년 3월 미세먼지 비상저감조치가 일주일 동안 발령되면서, 미세먼지로 인한 국민의 불안감은 점차 가중되고 있다. 본 연구는 공기정화식물이 적용된 바이오필터의 다중이용시설 내 적용성 평가를 위해 입자상 오염원의 실내 연속방출환경을 조성하여 오염원 저감효과에 대한 측정방법을 제안하고, 시스템의 실내공기질 개선 여부를 확인할 수 있는 기초연구를 진행하였다. 강의실을 대상으로 춘절기에 모니터링 1시간 전 모기향을 오염원으로 배경농도를 조성한 후, 스케줄에 따라 2시간 관수, 1시간 송풍하여 미세먼지의 저감능을 확인하였으며, 바이오필터 2m 전방에 PM10, PM2.5 및 온습도 센서를 설치하고, 3개 송풍구 중 중앙에 풍속 프로브를 설치하여 시계열 모니터링을 수행하였다. 바이오필터에 구비된 총 3개소의 송풍구 평균 면풍속은 0.38±0.16 m/s로 댐퍼 면적이 제외된 송풍구별 면적 0.29m×0.65m을 적용한 총 공조풍량이 776.89±320.16㎥/h로 산출되었다. 시스템 가동으로 평균온도 21.5~22.3℃, 평균상대습도 63.79~73.6%를 유지하여, 선행연구의 다양한 조건별 온습도 범위에 부합하는 것으로 판단된다. 시스템 공조부 구동을 통해 급격하게 상대습도를 상승시키는 효과를 효율적으로 운용할 경우, 계절에 따른 실내 미세먼지 저감과 적정한 상대습도 확보도 가능할 것으로 판단된다. 미세먼지 농도는 바이오필터 시스템 가동 전의 모든 주기에서 상승 현상이 동일하게 집계되었으며, 시스템 가동 후 1주기 송풍구간(B-1, β=-3.83, β=-2.45)에서 미세먼지(PM10)는 최대 28.8% 수준인 560.3㎍/㎥, 초미세 먼지(PM2.5)는 최대 28.0% 수준인 350.0㎍/㎥까지 저감되었다. 이후 미세먼지(PM10, PM2.5)의 농도는 2주기 송풍구간 감소(B-2, β=-5.50, β=-3.30)로 각각 최대 32.6% 수준인 647.0㎍/㎥, 32.4% 수준인 401.3㎍/㎥까지 저감되었고, 3주기 송풍구간감소(B-3, β=5.48, β=-3.51)로 최대 30.8% 수준인 732.7㎍/㎥, 31.0% 수준인 459.3㎍/㎥까지 저감된 것으로 확인되었다. 본 연구는 식생 바이오필터의 다중이용시설 내 설치와 유관한 관련 표준 및 규정을 참조하여, 객관적인 성능평가환경의 구축 방안을 제시할 수 있었다. 이를 통해 일반 강의실 환경 내에 보다 객관화된 모니터링 인프라를 조성하여, 상대적으로 신뢰성 있는 데이터 확보가 가능했던 것으로 판단된다.

축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가 (Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types)

  • 김기연;최홍림;고한종;김치년
    • Journal of Animal Science and Technology
    • /
    • 제46권2호
    • /
    • pp.283-294
    • /
    • 2004
  • 본 연구는 환기 방식 및 교반 유무에 따른 축분 퇴비화 시스템 내 대기 및 작업 환경을 평가하기 위해 수행되었다. 측정대상 가스상 물질인 암모니아, 황화수소, 악취농도의 경우 자연환기-미교반시 2.45ppm, 19.96ppb, 15.8, 강제환기-미교반시 7.61ppmm 31.36ppb, 30.2, 자연환기-교반시5.50ppm, 14.69ppb, 46.4, 강제교화기- 교반시 30.12ppm, 39.91ppb, 205.5가 평균적으로 발생되는 것으로 분석되었다. 각 운용조건에 따른 흡입성 분진과 호흡성 분진의 평균 농도는 자연환기-미교반시 368.6${\mu}g$/$m^3$,96.0${\mu}g$/$m^3$, 강제화기-미교반시 283.9${\mu}g$/$m^3$, 119.5${\mu}g$/$m^3$, 자연환기-교반시 208.7${\mu}g$/$m^3$, 139.8${\mu}g$/$m^3$, 강제환기-교반시 209.2${\mu}g$/$m^3$, 131.7${\mu}g$/$m^3$인 것으로 조사되었다. 총 부유 박테리아와 곰팡이의 경우 자연환기-미교반시 28,673cfu/$m^3$, 22,507cfu/$m^3$, 강제환기-미교반시 7,462cfu/$m^3$,3,229cfu/$m^3$, 자연환기-교반시 19,592cfu/$m^3$, 26,376.29cfu/$m^3$, 강제환기-교반시 18,645cfu/$m^3$, 24,581cfu/$m^3$가 평균적으로 발생되는 것으로 분석되었다. 대체로 가스상 물질은 자연환기와 교반을 하지 않는 경우보다 강제환기와 교반을 하는 경우에 더 많이 발생되는 경향을 보였다. 또한 흡입성 분진과 총 부유박테리아의 경우, 자연환기-미교반시에 대체로 더 높게 발생된 반면, 호흡성 분진과 총 부유곰팡이의 경우 강제환기-교반시에 더 많이 발생되는 경향을 보였다. 내부 온도와 상대습도는 입자상 물질과 생물학상 오염물질 발생에 영향을 주는 것으로 분석되었고, 암모니아와 황화수소는 축분 퇴비화시 발생되는 악취 원인물질로 입증되었다. 물리적 요인인 온도와 상대습도는 축분 퇴비화 시스템내에서 주로 입자상 오염물질과 생물학상 오염물질의 발생량에 영향을 미치는 주요인자로 입증되었는데, 시스템 내부 온도와 상대습도가 높으면 이것들의 농도도 높아지는 것으로 분석되었다.