• Title/Summary/Keyword: Indoor molds

Search Result 14, Processing Time 0.022 seconds

Molds Isolated from Pet Dogs

  • Jang, Kye-Seung;Yun, Yeo-Hong;Yoo, Hun-Dal;Kim, Seong-Hwan
    • Mycobiology
    • /
    • v.35 no.2
    • /
    • pp.100-102
    • /
    • 2007
  • Pet dogs have been considered to be involved in the contamination of indoor air by serving as a source of providing molds at houses. Currently, information on the molds originated from pet dogs is rarely available in Korea. The present study was carried out to obtain basic information on the fungi present on pet dogs. For this, fungal isolation was performed to the skin and hairs of 70 pet dogs at different houses and veterinary hospitals. A total of 44 fungal isolates were obtained from skin (27 isolates) and hairs (17 isolates) of the dogs investigated. Based on the observation of microstructures and colony morphology, and the ITS rDNA sequence analysis, the fungal isolates were identified at the level of genus. The identified isolates belong to the genera of Alternaria, Aspergillus, Beauveria, Chrysosporium, Cladosporium, Penicillium, Scopulariopsis, and Trichoderma. Among these genera, Aspergillus (25%), Cladosporium (23%) and Penicillium (20.5%) were 3 major genera. 63% of the 44 isolates showed color changes on dermatophyte test medium (DTM). When we tested the growth ability of 44 isolates at $37^{\circ}C$, 45% of the isolates were able to grow. These results show that pet dogs could carry fungi having a potentiality of affecting on human health.

Draft Genome Sequences of Three Airborne Aspergilli Series Versicolores

  • Gery, Antoine;Seguin, Virginie;Bonhomme, Julie;Garon, David
    • Mycobiology
    • /
    • v.50 no.1
    • /
    • pp.96-98
    • /
    • 2022
  • The Aspergilli of the section Nidulantes series Versicolores are among the most recurrent molds in indoor environments. These species cause damage to the quality of air. Indeed, they are responsible for allergies, aggravation of asthma and can even cause infections in immunocompromised patients. Molds belonging to the Versicolores series also produce sterigmatocystin, a mycotoxin classified as potential human carcinogen by the International Agency for Research on Cancer (group 2B). Here, we provide for the first time the genome of three species of the series Versicolores: Aspergillus creber, Aspergillus jensenii and Aspergillus protuberus which are the most abundant species of this series in bioaerosols. The genomes of these three species could be assembled with a percentage of completeness of 97.02%, 96.21% and 95.35% for Aspergillus creber, A. jensenii and A. protuberus respectively. These data will allow to study the genes and gene clusters responsible for the expression of virulence factors, the biosynthesis of mycotoxins and the proliferation of these ubiquitous and recurrent molds.

Study on sampling methods for mold from indoor air in domestic environment (국내 환경에서 실내 부유진균 포집 방법 연구)

  • Ahn, Geum Ran;Kim, Bo Young;Kim, Ji Eun;Son, Bu Sun;Park, Moo-Kyun;Kim, Sung-Yeon;Kwon, Myung-Hee;Kim, Seong Hwan
    • Journal of odor and indoor environment
    • /
    • v.16 no.1
    • /
    • pp.47-53
    • /
    • 2017
  • Mold is one of the important bio-aerosols affecting human health in the indoor environment. To manage mold contamination, it is necessary to use an appropriate method for its detection and enumeration. Recently, the impaction method of ISO 16000-18 has been established as one of methods to detect and enumerate molds in air. To investigate the general use of the impaction method for mold detection in domestic indoor environments, the suitability of the method was assessed using different antibiotics, media and air samplers. All of the three antibiotics tested - ampicillin, chloramphenicol and streptomycin - showed inhibitory effects on bacterial colony formation on MEA and DG-18 media, without inhibiting mold growth. Of these three antibiotics, ampicillin was the most effective. There was no statistical difference between MEA and DG-18 media in the measurement of mold concentration. The formation of discriminative colony morphology was more apparent in DG-18 media. No significant difference in the measurement of mold concentration was found between Andersen samplers and MAS-100NT samplers, which are two major samplers introduced in Korea.

Clinical Characteristics of Disability in Patients with Indoor Aire-Related Environmental Intolerance

  • Vuokko, Aki;Karvala, Kirsi;Suojalehto, Hille;Lindholm, Harri;Selinheimo, Sanna;Heinonen-Guzejev, Marja;Leppamaki, Sami;Cederstrom, Sebastian;Hublin, Christer;Tuisku, Katinka;Sainio, Markku
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.362-369
    • /
    • 2019
  • Background: Chronic nonspecific symptoms attributed to indoor nonindustrial work environments are common and may cause disability, but the medical nature of this disability is unclear. The aim was to medically characterize the disability manifested by chronic, recurrent symptoms and restrictions to work participation attributed to low-level indoor pollutants at workplace and whether the condition shares features with idiopathic environmental intolerance. Methods: We investigated 12 patients with indoor aire-related work disability. The examinations included somatic, psychological, and psychiatric evaluations as well as investigations of the autonomic nervous system, cortisol measurements, lung function, and allergy tests. We evaluated well-being, health, disability, insomnia, pain, anxiety, depression, and burnout via questionnaires. Results: The mean symptom history was 10.5 years; for disabling symptoms, 2.7 years. Eleven patients reported reactions triggered mainly by indoor molds, one by fragrances only. Ten reported sensitivity to odorous chemicals, and three, electric devices. Nearly all had co-occurrent somatic and psychiatric diagnoses and signs of pain, insomnia, burnout, and/or elevated sympathetic responses. Avoiding certain environments had led to restrictions in several life areas. On self-assessment scales, disability showed higher severity and anxiety showed lower severity than in physician assessments. Conclusion: No medical cause was found to explain the disability. Findings support that the condition is a form of idiopathic environmental intolerance and belongs to functional somatic syndromes. Instead of endless avoidance, rehabilitation approaches of functional somatic syndromes are applicable.

Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea (국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석)

  • Lee, Ju Yeong;Hwang, Eun Seol;Lee, Jeong-Sub;Kwon, Myunghee;Chung, Hyen Mi;Seo, SungChul
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.

A Study on the Development of a Range Hood Front Cover using Change Core Method (Change Core 공법을 이용한 렌지후드 Front Cover 개발)

  • Park, Jong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3363-3369
    • /
    • 2014
  • Recently, considerable effort has been made to maintain a pleasant and safe indoor environment in buildings. For this, the use of a ventilation system attached to a range hood in kitchens has prevailed. Accordingly, diversiform designs for range hoods have been used. Press molding is normally used for range hood construction for several reasons. On the other hand, its economic efficiency is low in the case of a small production work. Considerable research has been carried out to solve this problem and it is believed that it is useful to use the change core method to develop molds. This study designed the core of a mold using the change core method and a total of four processes were used in its manufacture. As a result, the press molds, which are needed for shorter production runs and whose form is changeable, were developed. In addition, after the measurements in three-dimensions, the specimen passed a test within a tolerance of ${\pm}2.00mm$.

Antimicrobial Properties of Cement Matrix using Pine Needle Extract (솔잎추출물을 혼입한 시멘트 경화체의 항균류 저항 특성)

  • Kim, Ho-Jin;Jung, Hyeon-Eui;Lim, Dong-Hyun;Han, Song-Yi;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.117-123
    • /
    • 2022
  • Recently, due to COV ID-19, many people are spending most of their time indoors. So, there is a rising interest on the indoor air quality in the field of building construction. The main sources for the indoor air pollution are human indoors activity, building materials, living supplies and the polluted air from outdoor. The Korean government has designated 17 indoor air pollutants including fine dust, total airborne bacteria, fungi and carbon dioxide, etc.. Most people are always exposed to assorted bacteria and molds in our daily life, because indoor environment for human, moderate temperature are humidity, it is favourable to the growth of most of bacteria and fungi. Pine needles have an antibacterial effect against bacteria and fungi. In this study, the antibacterial activity against bacteria and fungi was tested by cement matrix using pine needle extract. As a result, the cement matrix using pine needle extract showed antibacterial activities against bacteria, but in the case of fungi, it did not show antifungal activity.

A Study on the Measurement of Total Airborne Bacteria in the Process of Dismantling the Non-structure of Old Building (노후건축물 비구조체 해체과정에서의 총부유세균 발생량측정에 관한 연구)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Lee, Ji-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.313-314
    • /
    • 2021
  • An old building over 30 years old continue to increase. Therefore, there will be more dismantling of old buildings in the future. Safety management of dismantling works is being strengthened. However, no consideration has been given to the effects of dismantling workers and their residents due to environmental hazards arising from the demolition process. Only spray and dust prevention measures are subject to inspection to minimize dust generation considering civil complaints around the site of dismantling work. In this paper, residential buildings, which account for the largest proportion of old buildings, were collected and identify total airborne bacteria and floating fungi among environmental hazards caused by non-structural dismantling work. Measurement results showed that workers during dismantling work are working in places with 4.8 times more total airborne bacteria than indoor air quality maintenance standards. Related research is needed for the health of dismantling workers.

  • PDF

A Suggested Air Sampling Strategy for Bioaerosols in Daycare Center Settings (어린이활동공간에서의 바이오에어로졸 포집 전략)

  • Jo, JungHeum;Park, Jun-sik;Kim, Sung-Yeon;Kwon, Myung hee;Kim, Ki Youn;Choi, Jeong-Hak;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.324-333
    • /
    • 2016
  • Objectives: We aimed to compare the sampling performance of different flow-based impactor samplers for collecting fungal spores and bacteria and to explore the association of the level of bioaerosols with activity patterns of occupants in daycare center settings. Methods: For comparison of sampling performance, two different flow-based samplers (greater than 100 L/min or not) were selected; a low flow-based sampler (one-stage Andersen sampler) and two high flow-based samplers (DUO SAS SUPER 360 sampler, BUCK bio-culture sampler). We collected airborne mold and bacteria in 30 daycare centers with various levels of contaminated air. Three repeat samplings per each sampler were performed. Mold and bacteria were grown for 96 hours at $25{\pm}1^{\circ}C$ and 48 hours at $35{\pm}1^{\circ}C$, respectively. The Andersen and SAS samplers were used for investigating the association between the level of bioaerosols and the activity patterns of occupants in daycares. Particular matters 10($PM_{10}$), temperature, and relative humidity were monitored as well. Samplings were carried out with one-hour interval from 9 to 5 O'clock. For statistical comparisons, Kruskal-Wallis test, Wilcoxon's signed rank test, and multiple regression analysis were carried out. Results: The airborne level of molds by the low flow-based sampler were significantly higher than that of high flow-based samplers (indoor, P=0.037; outdoor, P=0.041). However, no statistical difference was observed in the airborne level of bacteria by each sampler. Also the level of bioaerosols varied by the time, particularly with different activity patterns in daycare centers. The higher level of mold and bacteria were observed in play time in indoor. Similarly, the concentrations of $PM_{10}$ were significantly associated with the level of bioaerosols (P<0.05). Conclusions: Our findings indicate that the flow rate of sampler, rather than total air volume, could be able to affect the results of sampling. Also, the level of airborne mold and bacteria vary behavior patterns of occupants in indoor of daycare settings. Therefore, different samplers with other flow rate may be selected for mold or bacteria sampling, and activity patterns should be considered for bioaerosol sampling as well.

Changes of Quality in Dried Omija (Schizandra chinensis Baillon During Storage) (건조 오미자의 저장중 품질변화)

  • 최윤희;정영근;박기훈;박문수
    • Food Science and Preservation
    • /
    • v.8 no.4
    • /
    • pp.351-355
    • /
    • 2001
  • This study was carried out to examine the of quality on the dried Omija according to its package materials and storage plates. The changes of moisture contents, anthocyanin content, molds damage rates, and color values were measured during storage. In the sealing up by the P.E file, the moisture contents of the dried Omija had just a little differences among the storage places, but in the gauze bag remarkably as the storage period goes on, especially in this case, 8 months later since the storage in the cool chamber, the damage rates of the dried Omija by the mold was 9.0%, twice as much as in the indoor bag packaging it was increasand after 10 months, that was lather high in the indoor and warehouse. The anthocyanin content of the dried Omija after the storage of 10 months was the highest at 0.05mm black P.E film package in the cool chamber, which was 55.7 mg/100g, but in the indoor and warehouse 39.7, 45.0mg/100g, respectively. These results show thats the storage conditions had an important effect on the quality of the dried Omija during the long-term storage.

  • PDF