• Title/Summary/Keyword: Indoor materials

Search Result 603, Processing Time 0.03 seconds

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

A Study for the Indoor Air Concentration of VOCs and HCHO in Newly Built and Remodeled Classrooms (신개축 교사내 실내공기중 휘발성유기화합물과 폼알데히드의 농도 특성)

  • Park, Jeong Ho;Yang, Su Myoung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.222-228
    • /
    • 2013
  • Objectives: The indoor air quality of newly-built (NC) and remodeled (RC) school classrooms was assessed. The primary aim was to show correlations between volatile organic compounds (VOCs) and formaldehyde (HCHO) pollutant levels. Methods: This study investigated the indoor air concentrations of VOCs and HCHO at 26 sites of newly built and 68 sites of remodeled classrooms located in South Gyeongsang Province between 2010 and 2012. VOCs in the indoor air were determined by adsorbent tube (Tenax TA) and automatic thermal desorption coupled with GC-MS analysis. Target analytes were five VOCs: benzene, toluene, ethylbenzene, xylene, and styrene. HCHO was collected with a 2,4-DNPH cartridge and analyzed by HPLC. Conclusions: This study estimated that indoor VOCs and HCHO concentrations in the classrooms were mainly affected by interior building materials and classroom equipment. For proper indoor air quality in schools, classroom air should be improved through reduction of hazardous materials by adequate ventilation, selecting environmental friendly materials, etc.

Micro Porous Clay Mineral Absorption / Desorption Moisture-Proof Performance of The Atmospheric Humidity and Decomposing The Polyamide Adsorption Performance Characterization of Formaldehyde (미세 다공질 광물과 아미드계 분해제의 적용을 통한 건축자재의 습도 조절과 폼알데히드 분해 성능 특성 평가)

  • Lee, Che Cheol;Kim, Yun Hwan;Yun, Seng Hee
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.105-109
    • /
    • 2014
  • The recent rising living standards, environment-friendly, well-being and health aspects of life in the basic gratification, as well as the desire for a pleasant environment emotionally environmentally friendly way of external space or industrial interest in the indoor environment, the manifestation. In particular, the biggest problem of the indoor environment has been emerged as a Sick House Syndrome indoor space that is provided to the building materials, and the impact on the domestic and the indoor environment, and clean the house in a health standards are specified as laws. The performance rating and the various materials to create environmentally-friendly standards for building materials. The more detail, Porous clay material, toxic substances released by applying the high humidity and the water itself, and to absorb the moisture, if the emissions, without a separate device, to maintain a comfortable indoor environment and at the same time, one of the causes of Sick House Syndrome breaking down harmful substances to absorb a comfortable indoor environment to maintain an environmentally-friendly building interior material studies. It is aimed at the development to multi-functional high performance eco-friendly construction materials, rather than through one feature performance, identify key features for national and international eco-friendly building materials can exert Water Vapour Adsorption raw, decomposed materials for the application and selection.

Numerical Study on Indoor Dispersion of Radon Emitted from Building Materials (건축자재로부터 방출되는 라돈의 실내 확산에 대한 수치해석적 연구)

  • Park, Hoon Chae;Choi, Hang Seok;Cho, Seung Yeon;Kim, Seon Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • Growing concerns about harmful influence of radon on human body, many efforts are being made to decrease indoor radon concentration in advanced countries. To develop an indoor radon reduction technology, it is necessary to develop a technology to predict and evaluate indoor inflow and emission of radon. In line with that, the present study performed computational modelling of indoor dispersion of radon emitted from building materials. The computational model was validated by comparing computational results with analytical results. This study employed CFD (Computational Fluid Dynamics) analysis to evaluate the radon concentration and the airflow characteristics. Air change rate and ventilation condition were changed and several building materials having different radon emission characteristics were considered. From the results, the indoor radon concentration was high at flow recirculation zones and inversely proportional to the air change rate. For the different building materials, the indoor radon concentration was found to be highest in cement bricks, followed by eco-carats and plaster boards in the order. The findings from this study will be used as a method for selecting building materials and predicting and evaluating the amount of indoor radon in order to reduce indoor radon.

Particle collection characteristics of carbon fiber sheet discharge electrode by particle size and application to air cleaner (탄소섬유 시트 방전극의 입자 크기 별 집진 특성 및 공기청정기로의 응용)

  • shin, Dongho;Woo, Chang Gyu;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.14 no.3
    • /
    • pp.81-88
    • /
    • 2018
  • The market for improving the indoor air quality is continuously increasing, and air cleaners are the representative products. As interest in indoor air quality increases, so are the ultrafine particle which are harmful to the human body. Despite its many advantages, electrostatic precipitators are less used in indoor air due to ozone production. In this study, the carbon fiber sheet was applied to the discharge electrode and compared with the conventional tungsten wire discharge electrode. The particle collection efficiency and the amount of ozone generation were measured for 10-100 nm particles. Furthermore, it was applied to commercial air purifier with electrostatic precipitator to compare particle removal performance. The carbon fiber sheet type discharge electrode generates a small amount of ozone, and thus it can be applied to improve indoor air quality.

The Role and Tendency of Contemporary Furniture as a Component of Space (공간 구성요소로써 현대 가구의 역할과 성향)

  • Yoo, Do-Hyun
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.2
    • /
    • pp.166-174
    • /
    • 2009
  • Most of the furniture in the past was dedicated to its original use such as storage and accommodation of articles or sitting tools, but the concept of furniture in contemporary indoor spaces is gradually increasing in its meaning while exchanging close impacts with other spatial components. Indeed, in contemporary furniture, a component other than furniture constituting a space would sometimes serve the common roles of furniture or sometimes furniture would include all indoor objects used to make people's living more convenient. This study reviewed the meaning of furniture and changes in its roles in contemporary indoor spaces and summarized the characteristics presenting a few examples. First, in contemporary indoor spaces, furniture as an independent object does not having a meaning any more. The fusion of functions with other components constituting indoor spaces is the most important characteristics in contemporary furniture and it has been already attempted in diverse ways through fusion with buildings surpassing fusion with other pieces of furniture or electric home appliances. Second, the arrangement conforming to the roles required by spaces and diverse forms of attempts are essential. Since furniture is an item the most closely related to human residential life, studies on human behaviors in spaces must precede. The efforts to enhance work efficiencies and used limited spaces more efficiently will be continued and explorations of new forms should be also continued. Third, with regards to manufacturing methods, new technologies should be applied more widely and furniture materials must be diversified through the use of new materials including not only cutting-edge new materials but also all the materials that can be applied to furniture such as conventional natural materials and environment friendly materials that can be recycled.

  • PDF

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

A Study on the Remodeling for Improvement of Acoustic Performance at Indoor Swimming Pool (실내수영장 음향성능 개선을 위한 리모델링에 관한 연구)

  • Kim, Nam-Don;Kim, Dae-Goon;Kim, Jae-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.3
    • /
    • pp.87-94
    • /
    • 2009
  • Recently, in accordance with the interesting on well-being as well as the revitalization of living athletics, it is current tendency that people who use the swimming pools are on increasing. However, because the most of indoor swimming pools have ever used the reflection finishing materials likely as the tile due to the property of its hydrophilic space, the inside of indoor swimming pool is vibrating too much, and some problem which the voice and music do not delivering clearly is occurring when swimming lessons or underwater aerobics(synchronized swimming) and swimming game. Based on such viewpoint, locating the object on actually built indoor swimming pool, this Study has ever grasped its physical acoustic property, and finally designed the indoor swimming pool that contains an optimum acoustic condition, by remodelling it through an acoustic simulation. It is considered that such study result could be utilized as the useful materials when constructing the similar indoor swimming pool, hereafter.

A prediction of indoor pollutant concentration using method mass transfer coefficient in multi-layered building materials (복합 건축자재의 물질전달계수를 이용한 실내 오염물질 농도 예측방법)

  • Kim, Chang Nam;Lee, Yun Gyu;Leigh, Seung Bok;Kim, Tae Yeon
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.53-58
    • /
    • 2007
  • In order to predict the indoor air pollutant, the VOCs emission rate is used through small chamber in the design process. However, the small chamber method has limitations as the convective mass transfer coefficient, the most important factor when predicting VOCs contamination of indoor air, is different between the small chamber result and the measured data in the actual building. Furthermore, the existing studies which analyzed mass transfer coefficient in the small chamber were directed on the small chambers developed at the time and FLEC(Field and Laboratory Emission Cell), thus, are different from the current small chamber which has been changed with improvements. The purpose of this study is to determine the emission rate of pollutant in multi-layered building materials, and predict the indoor pollutant concentration through the CFD(Computational of Fluid Dynamics) and CRIAQ2 based on the mass transfer coefficient on singled-layered building material by using the current small chamber widely used in Korea. Futhermore, this study used the new convective mass transfer coefficient(hm') which indicates the existing convective mass transfer coefficient(hm) including VOC partition coefficient(k). Also, formaldehyde was selected as target pollutant.