• Title/Summary/Keyword: Indoor lighting

Search Result 256, Processing Time 0.024 seconds

Glare control of a ceiling luminaire with movable cover (커버 가동에 의한 실내용 천정조명기구 눈부심 제어)

  • Kim, Hoo-Sung;Yeo, In-Seon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.47-50
    • /
    • 2007
  • This study attempts to prove a superiority of slide-cover lighting. In order to solve these problems, cover materials with slide-type, blind cover should be prepared to make it easy to replace the light bulbs in a short time and to introduce a sense of decorative taste. Depending on an user's linking, slide-type cover can always change the indoor atmosphere by adjusting the light emitted from the lighting and meeting with the blind unit

  • PDF

Invited Paper, A novel LCD using S-IPS technology for the application of public display

  • Kim, Kyeong-Jin;Park, Su-Jung;Choi, Sang-Ho;Kim, Jin-Ho;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1649-1651
    • /
    • 2008
  • A novel configured S-IPS LCD has been developed introducing a new compensation film with an anti-reflective layer. This new technology provides wide viewing characteristics as well as excellent visibility under bright indoor lighting or natural lighting.

  • PDF

A Study on the Supply obligations allotment rate of New Renewable Energy in Indoor Gymnasiums with the Application of a Daylighting System (집광채광시스템을 적용한 실내체육관의 신재생에너지 공급의무 분담률에 관한 연구)

  • Park, Yun-Ha;Lee, Yong-Ho;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.27-39
    • /
    • 2015
  • Under the goal of analyzing the compulsory supply share of new renewable energy according to the application of a daylighting system to indoor gymnasiums, this study conducted analysis of energy consumption and operation schedule at three indoor gymnasiums in the nation through a survey. The investigator did an Energy Plus simulation on Building A based on the analysis results and analyzed the supply share of new renewable energy in the saving effects of lighting energy according to the application of a daylighting system. As a result, When 92 prism daylighting system were installed in the upper ceiling of a stadium, they were able to meet the criteria for the minimum illumination for official games(Min : 600㏓) and optimum illumination for general games and recreations, thus saving lighting energy during the daytime(09:00~17:00). The resulting saving effects of lighting energy amounted to 44.4% for official games, 57.6% for general games, and 66.7% for recreations. In addition, the daylighting systems had a compulsory supply share of new renewable energy at 2.04% for official games, 2.75% for general games, and 2.62% for recreations, recording an average compulsory supply share of 2.5%.

Evaluation of Smart Lighting User Experience in Smart Safety Living Lab (스마트안전 리빙랩에서의 스마트 조명 사용자경험 평가)

  • Jo, Eun-Ji;Ryu, Do-Hyeon;Kim, Kwang-Jae;Lee, Gi-Hyun;Yun, Jung-Min;Cho, Jung-Hyun;Jeon, Kwang-sik;Lee, Ji-Yeon
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.4
    • /
    • pp.679-700
    • /
    • 2022
  • Purpose: Smart lighting adjusts brightness and color temperature according to weather, the user's activity, mood, etc. This study performed user experience(UX) evaluation of smart lighting in a living lab. The purpose of evaluating UX and analyzing the evaluation results is to improve user-friendliness and market competitiveness of smart lighting Methods: A living lab is a virtual or physical space where various stakeholders participate to develop, verify, and evaluate products, services, or systems in a real-life environment. In this study, an environment of using smart lighting was established in the Smart Safety Living Lab. Subjects performed UX evaluation after interacting freely with smart lighting in the Smart Safety Living Lab. Results: As a result of UX evaluation, it was confirmed that UX was overall excellent and subjects were satisfied with setting a desired indoor mood through smart lighting. However, operating the switch of smart lighting may be difficult due to its complexity, and it is needed to improve some functionalities such as the brightness range provided by smart lighting. Conclusion: This study is expected to contribute to establishing the way of UX improvement of smart lighting. This study is also expected to contribute to developing smart lighting as a high-quality product by reflecting the subjects' needs and UX derived in a real-life environment.

A Luminous Environment of Outdoor Spaces in Apartment Complexes (아파트 단지(團地) 외부공간(外部空間)의 빛 환경(環境)에 관(關)한 연구(硏究))

  • Kwon, So-Young;Ha, Mi-Kyoung;Lee, Hyo-Chang
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.237-241
    • /
    • 2006
  • The Qualitative improvements of outdoor spaces are unsatisfactory in comparison with that of indoor environment in existing apartments. Lately construction companies are differentiating the outdoor spaces of apartment complexes to meet needs of residents. However, high-rise buildings inherently have limitations on providing exposure to the outdoor settings and inappropriate lightings could have serious impacts on physical and psychological health of residents. Therefore, the purpose of this study is to provide useful information for the luminous environment of outdoor spaces through the analysis of current apartment complexes' lighting plans. Outdoor space of branded apartment complexes in Seoul, built after the year 2003, were researched. Through site visits, illumination level and lighting plans were investigated classified into entry area, passage area, plaza, rest area, exercise area, and play area. With the result, illumination level of apartment complexes researched was lower than KS illumination standard in all areas and the lighting plans were mostly shown in different condition of first intended lighting plan because of insufficiency of maintenance in lighting system. Therefore, it is need to provide better luminous environment to make outdoor space more lively and energetic at the night time.

  • PDF

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • v.16 no.3
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.

Effect of Thermal Environment and Illuminance on the Occupants Works based on the Electroencephalogram and Electrocardiogram Analysis (뇌파와 심전도 분석을 기반으로 한 온열환경 및 조도가 재실자의 업무에 미치는 영향)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Kim, Hyoung-Tae;Kim, Hyoung-Sik;Kuwak, Won-Tack;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.95-106
    • /
    • 2014
  • This research analyzed biosignals associated with the change of emotion from lighting felt by the occupants and task type under various indoor thermal environments and illuminance, and examined the biosignals' impacts on work. To this end, the indoor thermal environment was constructed on the basis of PMV (predicted mean vote) index value, and various indoor environments were created by changing the brightness of LED stands. In this manner, a variety of indoor environments were constructed, and experiments were carried out. This research evaluates the sensibility response to lighting through a questionnaire survey in the given environment and incorporates different types of error searches. In this way, changes were analyzed by measuring electroencephalogram (EEG) and electrocardiograms (ECG). As a result, all biosignals on the task type showed significant differences from the thermal environment change. When PMV index value was 0.8 (temperature: $25^{\circ}C$, humidity: 50 %), concentration and attention were the most activated. However, the biosignals did not show significant differences from the illuminance change. Concentration on an occupant's work capability was confirmed to be closely related to the thermal environment. As for the subjective emotional response to lighting, the occupants felt comfort as illuminance was lower, while they felt discomfort as illuminance was higher. However, there were no significant differences from the thermal environment change.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

A Study on Lighting Performance Evaluation of Light-Shelf using Crystal Face (결정면 적용 광선반 채광성능 평가 연구)

  • Lee, Heangwoo;Rogers, Kyle Eric;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.395-401
    • /
    • 2015
  • Recently, many research studies have been carried out on the efficiency of light-shelf daylighting systems, especially comparing performance improvements and the limitations of reflective surfaces and their lighting performance. In this study, a crystal face reflective surface is proposed. The objective of the study is to evaluate the lighting performance of a crystal face light-shelf through a performance study. The performance study was carried out in a full scale test-bed in order to calculate the light distribution and energy consumption utilizing the standard indoor illumination as an index. The conclusions of the performance study are as follows. 1) The optimal angle of incidence for daylighting for both the operable flat type light-shelf and the crystal face light-shelf are taken in the natural environment on the dates of the winter and summer solstices, as well as the autumn and spring equinoxes. 2) The application and installation of the crystal face light-shelf can produce a 29.9%~34.3% increase of light distribution within the indoor space. However, the increase of light distribution can also lead to a decrease in the uniformity ratio, a design challenge that should be considered when applying a crystal face light-shelf. 3) It is possible to achieve a 7.98%~13.3% greater reduction in energy consumption when applying a crystal face light-shelf than when applying a flat type light-shelf. The increase in the number of crystal faces should concur with the analysis of the energy reduction. A limitation of the study is that only one predetermined pattern was performance tested for a crystal face light-shelf. In order to carry out further research on crystal face light-shelves, additional performance studies are needed based on alternative patterns and designs.

Implementation of CAN-based Visible LED Communication Systems (CAN 기반 LED 가시광 통신 시스템 구현)

  • Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.102-107
    • /
    • 2011
  • LED-based lighting motivated by significant energy savings provides an opportunistic development of widespread free-space optical communications. Their transceivers have a variety of competitive advantages over RF including high bandwidth density, reliability, lower energy consumption, and long lifetime. But, it is difficult for existing buildings and structures such as ships and vehicles to install the communication cable to the ceiling. In this paper, controller area network (CAN)-based LED lighting communication systems were proposed. Results indicate the viability of developing inexpensive CAN interface modules and transceivers might be embedded in lighting products to support the indoor wireless networking.