• 제목/요약/키워드: Indoor fire

검색결과 210건 처리시간 0.019초

Causes of the Fire at an Indoor Shooting Range in Busan

  • Park, Woe-Chul;Lee, Nae-Woo;Jeong, Lee-Gyu
    • International Journal of Safety
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2010
  • On-site examinations and fire simulation were carried out to speculate on causes of the fire at an indoor shooting range in Busan. An experiment on the ignitability of unburned gunpowder was also conducted. Cigarette was the most likely source of ignition for the fire, while impact of a stray bullet failed to ignite the unburned gunpowder. The explosion in the shooting area was presumed to be caused by violent combustion of the polyurethane foam and unburned gunpowder accumulated on it. Fire safety measures include prohibit of use of profile polyurethane foam, complete clean-up of unburned gunpowder, and removal of steel components from the bullet trap.

옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구 (A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring)

  • 김두현;김은진;김성철
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

오리피스의 직경에 따른 감압성능에 관한 연구 (A Study on the Decompression Performance by the Orifice Diameter)

  • 박봉래;윤기조;장경남;최정웅;백은선
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.57-63
    • /
    • 2012
  • 현대건축물의 고층화는 소화설비의 적용을 어렵게 하여 기존 방식으로는 소화설비의 적합한 기능 부여에 한계가 따르기도 한다. 그중에서 옥내소화전설비는 건축물에 많이 설치된 소화설비로서 화재 시 관계인이 밸브조작 및 호스와 노즐을 수동으로 사용해야하는 설비이다. 따라서 방수압력이 높은 경우 반동력이 커 옥내소화전설비 사용의 어려움과 호스의 파손 등의 문제가 발생할 수 있다. 이를 방지하기위해 사용되는 감압방식 중 옥내소화전방수구인 앵글밸브에 감압밸브를 부착하여 사용하는 경우가 많은데, 고층건축물인 경우 감압밸브의 설치에도 불구하고 방수압력이 높아 안정적인 사용이 어려운 경우가 발생한다. 이를 확인하기위해 오리피스의 직경에 따른 감압성능을 측정하여 이를 근거로 반동력을 산출하였다. 이의 결과로 고층과 같이 높은 압력이 요구되는 상황에서 안정된 감압을 위해서는 다양한 직경의 감압밸브의 생산이 요구된다는 것을 알 수 있었다.

실내화재진압로봇의 현장운용성 향상을 위한 실용성 평가 (Evaluation of Field working Improvement for an Indoor Fire-fighting Robot)

  • 곽지현;이우준;김종권
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.126-131
    • /
    • 2008
  • Fire-fighters have been struggling against heat and dense smoke caused by fire when it occurs especially at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been recently developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to promote field working ability of the fire-fighting robot. As a result, heat resistance, water discharge and field working appeared satisfactory.

  • PDF

옥내소화전설비에서 도너츠형 적재방식의 소방호스 전개형태에 따른 방수준비시간 비교 (Comparison of Waterproofing Preparation Time with the Unfolded of Donut-type Staking Method Fire Hose in Indoor Hydrant System)

  • 홍석환;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.115-122
    • /
    • 2021
  • In this study, the purpose of this study was to examine the effect of twisting in the preparation of waterproofing in the process of unfolded donut-type staking method fire hoses in indoor hydrant system. The central pull-out method caused more twisting than the rolling method, and there was no significant difference in the number of twists according to the pull-out method in the case of male and female students. It was found that the time it took to untwist and prepare waterproofing was much shorter for male students. The angle valve and hose are connected, and the time to untwist and prepare for waterproofing after withdrawing the fire hose with the hose and nozzle connected was shorter than the unconnected state. In the rolling method, when a hose connected with two 15 m fire hoses was used and the angle valve-hose was connected, but the hose-nozzle was not connected, the least kinking occurred. The time to untwist and prepare for waterproofing was also the shortest. As a result, in the withdrawal method of the donut-type loaded fire hose in the indoor hydrant system, it is a rolling method rather than a central withdrawal method. With the angle valve and hose connected, unfold the fire hose with the hose and nozzle connected, if a large number of people unwind the twisted hose, the time to prepare for waterproofing can be shortened.

신경회로망을 이용한 옥내배선의 트랙킹 검지 기법 (Detection Technique of Tracking at Indoor Wiring using Neural Net work)

  • 최태원;이오걸;김석순;이수흠;정원용
    • 한국화재소방학회논문지
    • /
    • 제9권1호
    • /
    • pp.3-9
    • /
    • 1995
  • This paper is a study to dectect the tracking owing to deterioration of indoor wiring, and to prevent the electrical fire. After analysing the harmonics of waveshapes in load current and tracking current by FFT, a method of identifying the tracking was developed by using neural network. Fluoscent lamp, witch was mostly used in indoor, was chosen as the load used in this study. When the learning number in neural network was more then 30,000 times, an excellent neural net-work which could correctly identify the tracking was established. Therefore, the result of this study can be utilized as a basic material in various measuring instruments, such as an hotline inslation tester, earth tester in vehicles, and tracking fire alarm device, witch can detect the tracking under the condition of hotline.

  • PDF

에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구 (A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment)

  • 이태규;최경서;신연순
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권7호
    • /
    • pp.217-224
    • /
    • 2022
  • 오늘날 기술과 산업의 발전으로 특수건물이 늘어남에 따라 특수건물 내 화재 사고가 증가하고 있다. 그러나 정보통신기술의 빠른 발전에도 불구하고 낙후되고 실효성을 갖추지 못한 실내 화재 경보 시스템을 사용함으로 인해 인명 피해가 꾸준히 발생하고 있다. 본 연구에서는 음향경보를 이용하는 기존 실내 화재 경보 시스템이 건물 내 인원들에게 충분한 경보를 전달하지 못하는 '경보의 사각지대 문제'를 개선하고자 에지 컴퓨팅과 비콘을 활용한 화재 경보 시스템을 설계하고 구현하였다. 제안하는 개선된 화재 경보 시스템은 말단 센서 노드와 에지 노드, 사용자 애플리케이션, 서버로 구성된다. 말단 센서 노드는 실내 환경 데이터를 수집하여 에지 노드로 전송하고, 에지 노드는 전송받은 정보를 기반으로 화재 발생 여부를 모니터링 한다. 또한 에지 노드는 비콘 신호를 지속적으로 발생시켜 신호 범위 내의 사용자 애플리케이션이 설치된 스마트기기의 정보를 수집하여 서버 데이터베이스에 저장하고, 화재 발생 시 수집한 기기들의 정보를 바탕으로 모든 재실 인원에게 애플리케이션 푸시 형태로 화재 경보를 전송한다. 구현한 화재 경보 시스템의 적용 가능성을 검증하기 위해 강의실이 밀집한 대학교의 한 건물에서 신호 유효 범위 측정 실험을 진행한 결과, 에지 노드의 비콘 신호 범위 내에서 정상적으로 기기 정보를 수집하고, 수집한 정보를 바탕으로 특정 사용자들에게 신속하게 화재 경보를 전송함을 확인하였다. 이를 통해 수시로 변하는 출입자들의 정보를 유동적으로 수집하고, 이를 바탕으로 사용자와 매우 인접한 스마트기기로 경보를 전송함으로써 '경보의 사각지대 문제'를 해결하는데 적용할 수 있음을 확인하였다. 또한 실험 결과 분석을 통해 제안하는 화재 경보 시스템을 실내 공간의 특징에 따라 효과적으로 적용하는 방안을 제시하였다.

실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구 (Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors)

  • 최수길;진세영;박상민;남영재;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.37-46
    • /
    • 2020
  • 본 논문은 실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구이다. 공기질 측정인자들의 화재감지 경향성을 측정하기 위해 연기감지기 감도시험기를 이용한 작동실험과 UL 268에서 규정하고 있는 종이화재실험을 진행하였다. 연기감지기 감도시험기를 이용한 작동실험 및 UL 268 종이화재실험에 측정된 각각의 측정값을 교차 대입한 결과 공기질 측정기(IAQ) S1의 경우 PM 10(평균값제외), HCHO(평균값 및 최대값 제외), IAQ S2의 경우 PM 1.0, PM 2.5, PM 10, 연소가스분석기(CGA)의 경우 CO(평균값 및 최대값 제외)가 모든 실험 조건에서 연기발생에 따른 측정값의 변화를 통해 경향성을 관찰할 수 있었다. 특히, 본 실험 조건에서 측정되는 인자들 중 적응성이 가장 우수한 PM 10 및 CO는 화재감지 인자로 활용 가능할 것으로 생각된다.

출입문용 자동개폐장치를 설치한 실내체육관의 피난안전성 분석 (Analysis of the Evacuation Safety of Indoor Stadiums with Automatic Opening/Closing Exit Installations)

  • 안재천;공하성
    • 대한안전경영과학회지
    • /
    • 제22권3호
    • /
    • pp.15-21
    • /
    • 2020
  • This study analyzed the evacuation time in indoor stadiums when exits that automatically open/close when the fire sensor is triggered are installed as a means to improve the problem of closing certain exits. Firstly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 529.8 seconds when the automatic opening/closing exits are broken and employees are not present. Secondly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 445 seconds when the automatic opening/closing exits with 750mm width are working but employees are not present. Lastly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all spectators was 337 seconds when the automatic opening/closing exits with 1,500mm width are working and employees are present. As a result, it was revealed that the evacuation time is shortened when the automatic opening/closing exits are working. Additional comparative studies with actual simulations of people evacuating an indoor stadium and firefighting simulations considering smoke flow are necessary.

옥내소화전 호스 적재 방법이 신속한 화재진압에 미치는영향 (Effect of indoor fire hydrant hose loading method on rapid fire suppression)

  • 전재인
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.535-539
    • /
    • 2022
  • 이 연구는 옥내소화전의 효율적 호스 적재 방법에 대하여 분석한 것으로 실험 결과는 다음과 같다. 옥내소화전소방호스 적재 방법과 화재진압의 신속성을 비교하는 실험을 통하여 효과적인 소방호스 적재 방법을 도출하고자 한다. 접이식으로 소방호스를 적재하였을 때 평균 33초가 소요되었고, 한겹말은 소방호스 적재는 평균 69초가 소요되어유의미한 차이를 보였다. 첫째, 접이식 호스 전개 실험에서 실험대상자 A,C,D,E는 34초~37초로 각각 비슷한 수치를 나타냈다. 그 이유는 소방호스를 전개할 때 꼬임현상이 나타나지 않았고, 원활한 호스 전개가 가능하여 나타난 결과로 보인다. 실험대상자 B는 25초로 가장 낮은 전개 시간을 보였는데, 이는 B가 소방호스 전개 경험이 있어서 나타난 결과로 보인다. 둘째, 한겹말은 호스 전개 실험에서 실험대상자 A,B,C,E는 44초~76초로 각각 비슷한 시간대를 나타냈다. 그러나, 실험대상자 D는 110초로 유의하게 높게 나타났다. 그 이유는 소방호스를 전개할 때 호스 꼬임을 방지하기 위한 시도와 긴장을 통한 불안정한 심리상태가 소방호스 전개 시간을 높인 것으로 판단된다.