• 제목/요약/키워드: Indoor facility

검색결과 227건 처리시간 0.024초

Contemporary Safety Management of Virtual Golf in South Korea

  • MOON, Bo Ra;LEE, Seung Min;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • 제6권1호
    • /
    • pp.1-4
    • /
    • 2022
  • Purpose: The purpose of this study is to provide implications for virtual golf safety management in Korea through the literature review of current safety issues of virtual golf industry. Research design, data, and methodology: This study employed a qualitative approach to review prior studies and related documents presenting current safety perspectives of virtual sports facility management. First, the study reviewed the experiences of virtual golf players and safety criteria suggested from previous literatures. Second, two experts in sport facility management reviewed the manuscript including implications and provided their opinions including major implications and insights for virtual sport industry. Views of experts were added to the final manuscript. Results: This study found that installation standards and safety and hygiene standards by industry are enacted for the safety management of sports facilities, however, there is a need for standards to be adjusted because the contents are general, abstract, and lack detail, thus causing difficultly to secure effectiveness. Conclusions: For virtual golf courses, it is necessary to develop a safety inspection checklist that suits the characteristics of indoor virtual golf. In this line, safety criteria need to be developed with the consideration of characteristics of screen golf to establish an efficient safety management system and create a safe use environment.

전력선 통신과 공중 전화망에 의한 전력량의 원격 검침 시스템의 개발 (Development of the Remote Meter Reading System Using a Power Line Communication and PSTN)

  • 박종연;조호찬;최승지
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.103-106
    • /
    • 2002
  • This paper has studied a remote AMR(Automatic Meter Reading) system using the power line and the telephone line as a communication media and the digital power meter. In the developed system, because we have used the power line and telephone, the facility is very easy and then its cost is not expensive. The system includes following elements: a digital power meter, an indoor communication system using a power line modem and a telephone line interface system for sending data to the utility company.

  • PDF

Indoor Exposure and Health Risk of Polycyclic Aromatic Hydrocarbons (PAHs) via Public Facilities PM2.5, Korea (II)

  • Kim, Ho-Hyun;Lee, Geon-Woo;Yang, Ji-Yeon;Jeon, Jun-Min;Lee, Woo-Seok;Lim, Jung-Yun;Lee, Han-Seul;Gwak, Yoon-Kyung;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.35-47
    • /
    • 2014
  • The purpose of the study is to evaluate the pollution level (gaseous and particle phase) in the public facilities for the PAHs, non-regulated materials, forecast the risk level by the health risk assessment (HRA) and propose the guideline level. PAH assessments through sampling of particulate matter of diameter < 2.5 ${\mu}m$ ($PM_{2.5}$). The user and worker exposure scenario for the PAHs consists of 24-hour exposure scenario (WIES) assuming the worst case and the normal exposure scenario (MIES) based on the survey. This study investigated 20 PAH substances selected out of 32 substances known to be carcinogenic or potentially carcinogenic. The risk assessment applies major toxic equivalency factor (TEF) proposed from existing studies and estaimates individual Excess Cancer Risk (ECR). The study assesses the fine dusts ($PM_{2.5}$) and the exposure levels of the gaseous and particle PAH materials for 6 spots in each 8 facility, e.g. underground subway stations, child-care facilities, elderly care facilities, super market, indoor parking lot, terminal waiting room, internet caf$\acute{e}$ (PC-rooms), movie theater. For internet caf$\acute{e}$ (PC-rooms) in particular, that marks the highest $PM_{2.5}$ concentration and the average concentration of 10 spots (2 spots for each cafe) is 73.3 ${\mu}g/m^3$ (range: 6.8-185.2 ${\mu}g/m^3$). The high level of $PM_{2.5}$ seen in internet cafes was likely due to indoor smoking in most cases. For the gaseous PAHs, the detection frequency for 4-5 rings shows high and the elements with 6 rings shows low frequency. For the particle PAHs, the detection frequency for 2-3 rings shows low and the elements with 6 rings show high frequency. As a result, it is investigated that the most important PAHs are the naphthalene, acenaphthene and phenanthrene from the study of Kim et al. (2013) and this annual study. The health risk assessment demonstrates that each facility shows the level of $10^{-6}-10^{-4}$. Considering standards and local source of pollution levels, it is judged that the management standard of the benzo (a)pyrene, one of the PAHs, shall be managed with the range of 0.5-1.2 $ng/m^3$. Smoking and ventilation were considered as the most important PAHs exposure associated with public facility $PM_{2.5}$. This study only estimated for inhalation health risk of PAHs and focused on the associated cancer risk, while multiple measurements would be necessary for public health and policy.

Exposure Assessment and Health Risk of Polybrominated Diphenyl Ether (PBDE) Flame Retardants in Indoor Environments of Children's Facilities in Korea

  • Kim, Ho-Hyun;Yang, Ji-Yeon;Jang, Yun-Suk;Lee, Yong-Jin;Lee, Chung-Soo;Shin, Dong-Chun;Lim, Young-Wook
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.247-262
    • /
    • 2011
  • This study assessed the health risks of childhood exposure to PBDEs via different possible pathways in children's facilities and indoor playgrounds. When PBDE contamination was measured, it was determined through multiple routes, including inhalation of indoor dust, dermal contact with product surfaces and children's hands, and incidental dust ingestion. Samples were collected from various children's facilities (playrooms, daycare centers, kindergartens, and indoor playgrounds) during summer (Jul-Sep, 2007) and winter (Jan-Feb, 2008). The hazard index (HI) was estimated for non-carcinogens, and PBDEs, such as TeBDE, PeBDE, HxBDE, and DeBDE, were examined. The sensitivity to the compounds did not exceed 1.0 (HI) for any of the subjects in any facility. However, current data about toxicity does not reflect effects that were fully sensitive in children, so there is uncertainty in the dose-response data. The contribution rates of PBDEs were 71.4 to 96.1% and 3.7 to 28.2% for intake and inhalation exposure, respectively, indicating that intake of floor dust and inhalation are the primary routes.

다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화 (Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities)

  • 최임조;신승호;조완근
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권3호
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

CAD 객체 정보에 기초한 공간 정보 네트워크 모델의 구성 프로세스와 활용방안 (The process of Indoor Space Combination Network Model based on object oriented CAD data and its application)

  • 오정우;김경환;이윤선;안병주;김재준
    • 한국건설관리학회논문집
    • /
    • 제9권6호
    • /
    • pp.129-136
    • /
    • 2008
  • 첨단기술의 발달로 인해 건물은 대형화, 복합화되고 있으며, 이로 인해 실내공간을 효율적으로 관리할 수 있는 시스템의 필요성이 증가하고 있다. 또한 객체지향 3D CAD의 출현으로 인해 건물의 설계와 시공프로세스에서 계속적인 이용이 가능한 정보들이 제작되고 있다. 이런 정보들을 활용하여 건물의 유지관리 단계에서 실내공간을 효율적으로 관리할 수 있는 시스템을 구축하는 것이 필요한 시점이라 할 수 있다. 본 연구에서는 첨단기술을 융합한 공간정보 관리 시스템을 구축하기 위한 기초 연구로서 공간네트워크 모델을 자동으로 생성하는 프로세스를 정의하고 정의된 프로세스에 따라 샘플 모델을 구축하여 그 유용성을 검증해 보았다. 결과적으로 효과적인 공간 네트워크 모델이 생성되어 피난경로 검색이라는 기능을 효율적으로 수행하는 결과를 얻어낼 수 있었다.

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.

아파트 주민의 공동체 외식과 커뮤니티 시설에 대한 요구 및 만족도에 관한 사례조사 연구 (A Case Study on the Residents' Sense of Community and the Needs and Satisfaction of Community Facilities in Apartment Complex)

  • 신화경;김영주;이수진;조인숙
    • 가정과삶의질연구
    • /
    • 제29권1호
    • /
    • pp.83-93
    • /
    • 2011
  • The purpose of this study is to the examine sense of community of the residents living in an apartment complex and the relevant features of the community facilities provided in the complex, such as actual facility conditions, needs and satisfaction. Five apartment complexes constructed after 2000, each containing more than 500 units were selected for this case study. The actual conditions of the community facilities regulated by current laws were inspected. Those facilities were the administration office, gym, multi-purpose room, sauna and shower room, indoor and outdoor children's play-grounds, study room, etc. 37 residents were interviewed to access their needs and level of and satisfaction with the provided community facilities. Based on the results, we suggest that basic community facilities for exercise, child care and children's recresion need to be provided regardless of the apartment complex size. The respondents revealed a medium level of sense of community, which was psychologically limited to their apartment complex. Indoor and outdoor children's play-grounds had great potential to encourage social interaction between the residents. The findings point to a need for improvement of the current relevant regulations with the perspectives of flexibility and application in terms of space size and mandatory types.

도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험 (Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels)

  • 김창용;공하성
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.92-98
    • /
    • 2019
  • 이 연구는 옥내소화전설비에 자동화점추적 기능을 부가하여 화재 발생위치에 따라 방수노즐이 이동하여 유효하게 방수하는지를 방수중심 지향여부, 방수범위 유지여부, 방수형태의 일관성 유지여부로 구분하여 실험하고 결과를 고찰하였다. 첫째, 방수중심 실험결과는 최초 화원의 중심을 찾는 정확도는 시스템 설계에 있어서 유효한 결과를 도출하게 됨을 확인하였다. 둘째, 방수범위 실험결과 방수최대반경의 물 분사를 하는 경우 방수범위의 오차는 허용공차 범위 내에 들어가는 것으로 확인되었다. 마지막으로 방수형태 실험결과 형태의 변화 없이 정상동작하여 설정블록에 대하여 설계상태가 이상 없음을 확인하였다.