• Title/Summary/Keyword: Indoor environment in bedroom

Search Result 29, Processing Time 0.023 seconds

A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions (온도 및 습도 조건에 따른 침실 공기환경에 관한 연구)

  • Kim, Dong-Gyu;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

A Study on Sleep Environment in Bedroom and Segmentation of Sleepers in Seoul and Metropolitan Area (서울시 및 수도권 거주자의 침실환경과 침실 사용자그룹 세분화에 관한 연구)

  • Kim, Bi-Na;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • Sleep has big influence on our life, for example productivity, character formation of babies, mortality and the people who suffered from sleep problem are also diverse. Therefore, indoor environmental supports for good sleep, might be different with the situation and need of respective person. The objectives of this study are: 1) to investigate the current bedroom condition, sleep problem, and life pattern of Korean. 2) to classify Korean into several groups and explain their characteristics relevant to sleep, in order to understand Korean's need for good sleep. The questionnaire was sent out to Seoul and its environs in Jan.$\sim$Feb. 2008, and total of 702 questionnaires were collected. The research on the bedroom condition was conducted around perceived influence of environmental factors, opening and closing of the door, cooling and heating strategy, clo value during sleep, bedding type, lighting, sharing bedroom. People are divided into 6 groups by 8 factors, and 5 groups could be seen that they need some management for good sleep because of their sleep problem.

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data - (치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju-Young;Lee, Ki-Ho;Yun, Young-Il;Lee, Hyo-Won
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

A study on sleep environment in bedroom and segmentation of sleepers in Korea (한국인의 침실환경과 침실 사용자그룹 세분화에 관한 연구)

  • Kim, Bi-Na;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.291-296
    • /
    • 2008
  • This paper reports on the results of a questionnaire survey on actual conditions of sleep environment, sleep problems and sleep patterns in bedroom of house. The objectives of survey are: 1) classifying Korean people into several groups by sleep environment condition, sleep problem and life pattern, 2) describing the characteristics of user groups, and 3) searching needs of support for each user group. Despite of several studies about sleep condition that researched in advance, they weren't considered about user's respective characters. So it seems necessary for more studies about users' needs, and segment users to grasp their each detail needs. Therefore, this study conducted questionnaire survey gathering relevant information to classify user groups and to investigate the current bedroom condition. In the result, 702 respondents were divided into six clusters by extracted eight factors. Four clusters of them had some problems for sleep, so it could be seen that they need environmental solution for their good sleep. As the further objective, it will be connected to develop the good sleep system.

  • PDF

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement (침실 공기질 개선을 위한 강제 환기횟수에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

A Study on the Evaluation for Elderly Housing Environment (노인주거환경 평가 틀에 관한 연구)

  • Shin, Hwa-Kyoung;Lee, Joon-Min
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.273-277
    • /
    • 2009
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The scope of evaluation was limited to the indoor spaces and outdoor spaces of housing as it was thought that the elderly spend much more time at indoor, outdoors, considering their physical characteristics. The study are as follows ; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

  • PDF

Comparison of Five Pollutant Levels between Inside and Outside Homes (主要 汚染物質에 대한 家庭에서의 室內外 濃度比較)

  • 金潤信
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.27-32
    • /
    • 1987
  • As part of an air pollution epidemiological study of asthmatics residing in the Houston area, an air monitoring system provided data on the indoor and outdoor measurements of major pollutant gases sampled at selected residences during May ~ October 1981. Continuously monitored pollutant gases included sulfur dioxide ($SO_2$), nitrogen dioxide($NO_2$), nitric oxide(NO), carbon monoxide(CO), and ozone($O_3$). Outdoor levels for each pollutant were compared with their indoor levels(bedroom, kitchen, living room). Mean concentrations of each pollutant in the kitchen, and living room exceeded the mean levels outside except for ozone, while average bedroom levels for all gases except for $O_3$ and $NO_2$ were found higher than the corresponding outside levels. Indoor/ outdoor ratios for $SO_2$, NO, and CO were 1.8 ~ 2.7 times the outdoor levels, but indoor/ outdoor ratios for $NO_2$ and $O_3$ were 0.99 and 0.06, respectively. The impact of several important household characteristics (type of cooking fuel and cigarette smoking) on the indoor levels for these gases is evaluated.

  • PDF

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF