• Title/Summary/Keyword: Indoor disaster response

Search Result 13, Processing Time 0.024 seconds

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

A Study on Technology Commercialization of Indoor Floor Advertising Lighting Devices Applicable to Advertisements and Disaster Situations (광고 및 재난상황에 적용 가능한 실내용 바닥광고 조명장치의 기술사업화 방안 연구)

  • Kwang-Soo Kim;Woon-Seek Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.32-40
    • /
    • 2023
  • Recently, there are some outdoor floor advertising lighting devices as one of the active marketing methods. However, for outdoor use, there are many restrictions due to the Outdoor Advertisement Act, according to requiring high-output heat generation, waterproofing, and AC power, etc. The purpose of this study is to develop a Duo Light product optimized for indoor use through publicity and information guidance in normal times and automatic evacuation route guidance display in case of disaster, in conjunction with disaster safety. To that end, patent search and patent association analyses were conducted, and a comparative analysis with commercial products was conducted as a case study. In addition, prototypes were designed and produced through the review of operation principles, where field environment surveys and self-tests were conducted. Also, technology roadmaps were presented by preparing plans for expandability and advancement of products. For the analysis of technology commercialization, the feasibility of technology commercialization was examined through the analysis of Jolly's Model and Lean Canvas Model. The results of this study will be able to contribute to minimize human damage through the effective response to disasters, which can increase the effect of indoor advertising by using the proposed indoor floor advertising lighting device in advertising and disaster situations.

Spatiotemporal Routing Analysis for Emergency Response in Indoor Space

  • Lee, Jiyeong;Kwan, Mei-Po
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.6
    • /
    • pp.637-650
    • /
    • 2014
  • Geospatial research on emergency response in multi-level micro-spatial environments (e.g., multi-story buildings) that aims at understanding and analyzing human movements at the micro level has increased considerably since 9/11. Past research has shown that reducing the time rescuers needed to reach a disaster site within a building (e.g., a particular room) can have a significant impact on evacuation and rescue outcomes in this kind of disaster situations. With the purpose developing emergency response systems that are capable of using complex real-time geospatial information to generate fast-changing scenarios, this study develops a Spatiotemporal Optimal Route Algorithm (SORA) for guiding rescuers to move quickly from various entrances of a building to the disaster site (room) within the building. It identifies the optimal route and building evacuation bottlenecks within the network in real-time emergency situations. It is integrated with a Ubiquitous Sensor Network (USN) based tracking system in order to monitor dynamic geospatial entities, including the dynamic capacities and flow rates of hallways per time period. Because of the limited scope of this study, the simulated data were used to implement the SORA and evaluate its effectiveness for performing 3D topological analysis. The study shows that capabilities to take into account detailed dynamic geospatial data about emergency situations, including changes in evacuation status over time, are essential for emergency response systems.

Simulation Study to Verify Manned-Unmanned Teaming Operations in Indoor Fire Response (실내 화재 대응 시 유·무인 복합운용 검증을 위한 시뮬레이션 연구)

  • Jin-Hyeon Sung;Seong-Hyeon Ju;Bong Gu Kang;Kyung-Min Seo
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.3
    • /
    • pp.37-50
    • /
    • 2024
  • In indoor disaster scenarios such as fires or gas leak, prompt rescue operations are essential to minimize expected casualties. This paper proposes a simulation model that applies the concept of Manned-Unmanned Teaming (MUM-T) for effective search and rescue in indoor fires. To this end, we first identify appropriate agents to model search and rescue operations. The proposed agent-based simulation consists of a fire and map model, an occupant model, a drone model for occupants searching, a rescuer model for searching and rescuing occupants, and a control center model that assigns missions to drones and rescuers. The agent models identified according to the MUM-T concept interact with other agents during the fire response simulation. Simulation experiments were conducted for search and rescue operations in three scenarios, one consisting of only rescuers and two with mixed rescuers and drones for MUM-T. The simulation results indicated that a drone applied to MUM-T could replace an average of four rescuers. The simulation method proposed in this study is expected to improve the efficiency of search and rescue operations in indoor disaster situations and minimizing the loss of life.

The Study on the Derivation of Performance Guidelines for Indoor·Outdoor Temporary Housing Facility (실내·외 임시주거시설의 성능 가이드라인 도출에 관한 연구)

  • Ju, Jaeseong;Park, Jiyong;Gwak, Donghwa;Park, Mijin
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.271-279
    • /
    • 2018
  • Purpose: This study is designed to develop performance guidelines for temporary residential facilities inside and outside the building to improve the residential habit of the victims caused by a disaster. Method: Performance items were set up by analyzing the disaster response system and prior study for eliciting performance guidelines and conducting field surveys of temporary housing facilities and interviews of temporary residential facilities for eliciting relevant performance guidelines. Results: The performance of temporary housing facilities in and out of the country was largely classified as technical, environmental and social, and each presented performance guidelines. The derived performance guidelines were generally similar, although some were similar due to indoor/outdoor characteristics. Conclusion: The performance guidelines presented in this study to improve the residential habit of the victims are applied in practice, and continuous improvement through feedback of results is required.

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

Numerical Analysis of Airborne Infection Control Performance of Germicidal Systems in a Temporary Shelter (수치해석을 이용한 임시대피소 내 공기감염확산 저감장치의 성능 분석)

  • Park, Jeongyeon;Sung, Minki;Lee, Jaewook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • Purpose : When natural disaster occurs, the victims are evacuated to temporary shelters such as indoor gymnasiums or large space buildings until their homes are recovered. If someone in this temporary shelter is infected with an airborne infectious disease, it becomes easier for the disease to spread to the other people in the shelter than it would be under normal conditions. Therefore, temporary shelters need to provide not only water and food but also hygienic indoor conditions. Methods : In this study, the use of mechanical systems such as ultraviolet germicidal irradiation (UVGI) systems and air cleaners were simulated using numerical analysis to find out how these systems can control airborne infection in temporary shelters. An indoor gymnasium was selected as a temporary shelter for the numerical simulation model considering Korea's post-disaster response system. Influenza A virus was assumed as an airborne infectious disease and the diffusion of the virus was made by one person in the shelter. Results : The result of this study showed that the UVGI systems disinfected the virus more effectively than the air cleaners by creating a more stable airflow after the disinfection process. The air cleaners could remove the virus but since it created an unstable airflow in the temporary shelter, the virus was condensed to a certain area to show a higher virus concentration level than the source location. Implications : In the temporary shelter, it is necessary to use UVGI systems or air cleaners for hygienic indoor conditions.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

A Study on Indoor Environment Safety Level Certification of Educational Facilities and School Safety Level Evaluation (교육시설 안전 등급 인증과 학교 안전도 심사에 대한 연구)

  • Myoung-Kwan Kim;Young-Guk Kwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.17-28
    • /
    • 2023
  • This study aimed to verify the validity of the evaluation items and weight determination of the indoor environmental safety area, which has the most frequent accidents, among the safety certification evaluations of educational facilities by the Ministry of Education of the Republic of Korea, which has been conducted since May 2021. As a preceding study, the evaluation items of the school safety evaluation checklist being implemented in the US state of Vermont were compared, and the causes of accidents judged by teachers in the accident experiences written by 200 Korean teachers were compared with the safety certification evaluation items belonged to the Ministry of Education. In addition, research literature using the AHP analysis technique on safety risks of elementary and secondary schools in China and safety evaluation index study cases of 539 elementary school children in Indonesia were analyzed. Through these preceding studies, measures to add and adjust evaluation items were derived and the validity and importance rankings of evaluation items were calculated through AHP questionnaires to teachers and safety experts. In addition, a survey was conducted on 104 ordinary people to verify the results of expert analysis. As a result of expert AHP analysis, 'safety education and disaster response training (.396)' was the highest priority for the relative importance of the first layer, followed by 'safety measures (.387)' and 'building materials'. Safety (.216)' was found to be the highest priority. In the overall importance ranking of the 13 second-tier screening items, safety accident prevention education had the highest priority and disaster preparedness training ranked second, proving that the Ministry of Education's review weight was underestimated. In addition, slip and collision accident countermeasures, which were not in the existing Ministry of Education review items, ranked 4th, laboratory practice room safety measures ranked 6th, and sanitation, cleanliness, hazardous substance management, and cafeteria/cooking room safety measures ranked 9th, indicating a significant level of importance. Referring to the importance ranking, which is the result of this study, it is suggested that it is necessary to review the weight of each review item again.

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust and Wind Velocity (분진 및 풍속에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Chun-Ha;Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • The present article discusses the response characteristics of smoke detector chamber due to dust and wind velocity. Although situations have improved in terms of early sensing of fires as the smoke detectors are applied indoors, studies tend to place insufficient focus on the side effects and malfunction that can be caused by diversified life dust produced indoors and environmental requirements, etc. Therefore, in the present study, 4 types of photoelectric smoke detectors with different forms and structures of smoke chamber were selected as the experimental objects, and dust test was conducted with fly ash, talcum powder and fiber dust as experiment samples to study indoor applicability of the smoke detectors in terms of their response to diversified dust and wind velocity. Also, to observe response characteristics due to pollution level inside the smoke chamber, wind velocity for dust test were set additionally at 0.25 m/s, 0.5 m/s, and 1.0 m/s. Based to the experimental results, fly ash, talcum powder, and fiber dust (black hair powder) were found to be suitable at the dust test reference wind velocity conditions of 0.25 m/s for both operation test and non-operation test after dust application. On the other hand, under the harsh wind velocity conditions of 0.5 m/s and 1.0 m/s, malfunction of unwanted alarm was observed in non-operation tests in the case of fly ash and talcum powder, and non-operation was confirmed to occur in the case of fiber dust as the alarm failed to operate normally in operation tests.