• 제목/요약/키워드: Indoor and outdoor

검색결과 1,346건 처리시간 0.031초

Variations in the Thermal Performance of R22 and R410A Refrigeration Systems Depending on Operation Conditions

  • Jeong, Ji-Hwan;Kweon, Young-Chel;Chang, Keun-Sun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.10-20
    • /
    • 2004
  • Experiments have been conducted in order to make comparisons of characteristics of a R410a cycle with a R22 cycle in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor and outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles constructed for this study share all components except compressor, accumulator, oil separator, and piping. The measurements were made using a psychrometric calorimeter. The experimental results show that the R410A cycle has several advantages for indoor units while the R22 cycle yields better performance for outdoor units.

시간행동 행태을 이용한 영업용 운전자들의 이산화질소 개인 노출량 예측 (Estimation of Exposure to Nitrogen Dioxide in Professional Drivers Using Time Activity Pattern)

  • 방용남;손부순;양원호;박종안;장봉기
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.20-26
    • /
    • 2001
  • personal nitrogen dioxide(NO$_2$) exposures for 31 professional drivers were measured using passive sampler and time activity diary in Asan and Chunan area, and were estimated using time-weighted average model. Mean concentrations of driver’s indoor and outdoor were 24.7$\pm$10.7 ppb and 23.3$\pm$8.3 ppb, respectively with indoor/outdoor of 1.1. Mean personal NO$_2$ exposure was 30.3$\pm$9.7 ppb. Personal NO$_2$ exposures were strongly correlated with indoor car NO$_2$ levels ($R^2$=0.80) rather than residential indoor NO$_2$ level ($R^2$=0.55). and outdoor NO$_2$ level ($R^2$=0.50). The driver’s NO$_2$ exposure using LP-gas with 24.4$\pm$8.0 ppb were statistically different from those using diesel with 36.3$\pm$14.1 ppb(p<0.01). The effect of driver’s smoking for personal NO$_2$ exposure was not found. It was considered that the main NO$_2$in driver is transportation. Since drivers mostly spent their times in indoor and inside car, time-weighted average model could be used to estimated personal NO$_2$ exposure using time activity diary, Though we did not measure all microenvironments, the estimated personal NO$_2$ exposures with 26.9$\pm$10.2 ppb were statistically correlated with measured personal NO $_2$ exposures30.3$\pm$9.7 ppb ($R^2$=0.89). The mean and standard deviation of personal NO$_2$ exposure using Mote-Carlo simulation were 26.6$\pm$7.2 ppb.

  • PDF

휘발유 및 환경 담배 연기 관련 벤젠 노출 (Exposure to Benzene Associated with Gasoline and Environmental Tobacco Smoke)

  • 조완근;문경조
    • 한국환경과학회지
    • /
    • 제8권3호
    • /
    • pp.319-323
    • /
    • 1999
  • This study was designed to evaluate the exposure to benzene by residents in neighborhoods near a major roadways, by persons waiting buses, and by drivers and service station attendants while refueling. It was confirmed that the outdoor air benzene concentrations near the major roadways were higher than those further away from the sources. However, neither the indoor air nor breath concentrations were different for two specified residential areas. Smoking was confirmed as an important factor for the indoor air benzene levels. Persons waiting buses, drivers and service station attendants were exposed to elevated benzene levels compared to even the residents in neighborhoods near a major roadways. The mean benzene concentration at bus stop was 2.7 to 6.9 times higher than the mean ambient air concentration. The mean benzene concentrations in the breathing zone of drivers and service station attendants were 95 to 160 and 120 to 202 times higher than the mean ambient air concentrations, respectively.

  • PDF

해수 및 담수에서 장구균과 총대장균군의 불활성화 (Inactivation Rate of Enterococci and Total Coliforms in Fresh Water and Sea Water)

  • 김종민;정원화;최희진
    • 한국물환경학회지
    • /
    • 제25권1호
    • /
    • pp.136-141
    • /
    • 2009
  • Inactivation rates between enterococci and total coliforms were compared in order to find the suitability of enterococci as an indicator microorganism under various experiment conditions - freshwater and/or seawater, indoor and/or outdoor conditions. In case of indoor laboratory experiments, inactivation rates of enterococci ($k_D$: 0.050~0.082) were faster than those of total coliforms ($k_D$: 0.034~0.045) in freshwater matrix. In seawater matrix, however, survival rate of enterococci was longer than that of total coliforms at two out of three experiments in indoor condition. When incubated in outdoor conditions, enterococci were inactivated significantly more rapidly than total coliforms both in freshwater and seawater matrices. With these results, enterococci appear to be less suitable than total coliforms in terms of inactivation rates.

운전조건 변화에 따른 R-22 냉동사이클과 R-410A 냉동사이클의 성능변화 비교 (Comparison of Performance Variation between R-22 and R-410A Refrigeration Systems)

  • 박태준;이민규;정지환;장근선
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.166-176
    • /
    • 2003
  • Experiments have been conducted in order to make comparisons of a alternative refrigerant (R-410A) cycle characteristic with an existing refrigerant (R-22) cycle characteristic in terms of cooling capacity and coefficient of performance (COP). The parameters examined in the present work include air flow rate, indoor/outdoor air temperatures, and indoor relative humidity. These two refrigeration cycles share all components except compressor, accumulator, oil separator, and piping connecting them. The measurements were made using an air-enthalpy calorimeter. The experimental results show that the R-410A cycle has many advantages over indoor conditions while the R-22 cycle has better performance over outdoor conditions.

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구 (A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season)

  • 국찬;전지현;신용규
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

일부 학교 내 총부유세균 및 미세먼지의 상관성 비교 (Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces)

  • 서혜경;안하림
    • 한국산업보건학회지
    • /
    • 제34권2호
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

전북 고창지역 학교 실내외 환경의 중금속 오염 특성 (Contamination Characteristics of Heavy Metals in Indoor, Outdoor and Playground of Schools in the Gochang-Gun, Chonbuk Province of South Korea)

  • 김용환;정덕호;조규성
    • 한국지구과학회지
    • /
    • 제27권1호
    • /
    • pp.73-82
    • /
    • 2006
  • 먼지시료는 전라북도 고창군에 있는 10개 중 고등학교에서 채취하였다. 교실 내의 칠판 위, 전등 반사판 위, 게시판 위, 물품장 위에 쌓인 분진 등의 먼지와 창틀 밖 난간 등에 쌓인 먼지시료, 그리고 운동장에서 총 45개의 시료를 채취했다. 채취한 먼지 시료를 Thompson and Wood(1982)의 방법으로 화학처리 한 후 Cd, Co, Cr, Cu, Ni, Pb, Zn, Mn 등 8개의 원소를 정량 분석했다. 교실 내 먼지 시료 중에 Cd, Cu, Pb, Zn 등의 중금속 함량이 높았다. 또한 교실 외 먼지 시료 중에는 Cu, Ni, Pb, Zn의 함량이 높았다. 먼지 시료 중 Cd(4.6 ppm), Cu(124 ppm), 그리고 Zn(350 ppm) 농도는 세계 평균 지표 토양과 환경오염기준 보다 매우 높다. 이러한 경우는 전주시 중 고등학교의 먼지 시료 분석과 유사하다. 국내 선행연구와 비교했을 때 교실 내 외 환경은 Cu, Zn을 제외하고 농축이 심하다. 운동장 환경은 전주시의 교통량이 많은 주거 도로와 주 도로변, 운동장에 있는 먼지 중의 중금속 함량 보다 낮았다. 운동장 먼지 시료에서 오염지수가 1.0 이상인 중금속 오염은 1개 학교에서 나타났지만 교실 내 외 먼지 시료에서 오염지수가 1.0 이상인 중금속 오염은 7개 학교에서 나타났다. 산업화가 덜 된 농촌 지역의 학교라 할지라도 교실 내에는 중금속의 오염양상이 도시 지역의 학교와 같았다. 이는 교통량의 상대적 차이나 산업화의 정도와 관계없이 실내에서 중금속 오염이 동일하게 일어나고 있음을 보여준다.

목조문화재에서 계절에 따른 부유 진균의 분포 및 다양성에 관한 연구: 순천 선암사를 중심으로 (Seasonal Distribution and Diversity of Airborne Fungi in a Wooden Cultural Heritage Site: A Case Study of The Seonamsa Temple, Suncheon)

  • 홍진영;김영희;이정민;김수지;조창욱;박지희
    • 한국균학회지
    • /
    • 제46권2호
    • /
    • pp.122-133
    • /
    • 2018
  • 순천 선암사는 산림과 계곡으로 둘러싸여 가파른 지형에 위치하고 있으며 평지보다 온 습도는 높고 바람의 세기가 약하여 생물 피해가 우려되는 곳이다. 이에 계절마다 진균상 조사를 통해 실내 외 공기질에 분포하는 진균의 농도와 다양성을 조사하였다. 외부 공기질에 분포하는 진균의 농도는 봄($276CFU/m^3$)에 가장 높았고, 가을($196CFU/m^3$), 여름($128CFU/m^3$), 겨울($24CFU/m^3$) 순으로 감소하였다. 가장 하단에 위치한 지장전은 여름철에 $337.4CFU/m^3$, 가장 상단에 위치한 원통전은 가을철에는 $333.4CFU/m^3$의 가장 높은 농도를 나타냈다. 실내 외 공기질에서 부유균 농도의 차이가 컸던 계절은 여름철이었으며 $128CFU/m^3$인 외부보다 실내 공기질에 최소 0.5배에서 최대 3배 정도의 많은 진균이 부유하고 있었다. 부유 진균이 가장 많이 수집된 계절은 봄철이었지만 다양성은 여름과 가을철 공기질에서 더 높았는데 여름에는 28속 45종, 가을에는 25속 47종의 진균이 확인되었다. 특히, 가을철에는 모든 조사 지점에서 부유 진균의 분포도가 가장 높았는데 그 중에서 자낭균이 86%를 차지하였고 Cladosporium속이 우점하였다. Penicillim속은16종이 검출되어 종다양성이 가장 높았고 야외보다는 여름과 가을, 겨울철의 실내 공기질에 주로 분포하였다.