• 제목/요약/키워드: Indoor Pressure

검색결과 249건 처리시간 0.028초

실내 부하 변동에 따른 탄화수소계 냉매를 이용한 히트펌프 성능에 관한 실험적 연구 (An Experimental Study on Performance of Heat Pump System Using Hydrocarbon Refrigerants by Changing Indoor Load)

  • 김재돌;성광훈;정석권;윤정인;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.204-210
    • /
    • 2006
  • This study presents heat pump system characteristics using hydrocarbon refrigerants as alternative refrigerant for R-22 with respect to the variation of indoor load. Pure R-22 and R-290. R-600a, R-1270 were considered as working fluids The experimental apparatus was constructed to investigate the performance of heat pump using the air as a heat source. The performance were calculated based on compression shaft work. refrigeration capacity. pressure ratio, discharge temperature and COP. The experimental results show that the COP and refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. Through the above. hydrocarbon refrigerants are good alternatives in the heat pump system for R-22.

PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구 (Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권1호
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

롤필터를 장착한 객차용공기청정장치 개발 (The development of Air-cleaner with Roll Filter inside railroad passenger car)

  • 이영섭;남궁석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

퍼지 로직 적용 PID 제어를 이용한 멀티형 열펌프의 용량조절 (Capacity Modulation of a Multi-Type Heat Pump System using PID Control with Fuzzy Logic)

  • 김세영;김민수
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.810-817
    • /
    • 2001
  • Performance of a water-to-water multi-type heat pump system using R22 which has tow indoor units has been investigated experimentally. The refrigerant flow rate of each indoor unit was regulated by an electronic expansion valve and the total refrigerant flow rate of the system was controlled by a variable speed compressor. In the system, evaporator outlet pressure of refrigerant and outlet temperatures of secondary fluid from indoor units were selected as control variables. Experiments were executed for both cooling and heating modes using PID control method with fuzzy logic, and results of the test are compared with a classical PID method. In the case of PID control with fuzzy logic, the fuzzy control rules corrects PID parameters each time. Results show that PID control with fuzzy logic has the merits of quick response and reduced overshoot.

  • PDF

Psycho-acoustic evaluation of the indoor noise in cabins of a naval vessel using a back-propagation neural network algorithm

  • Han, Hyung-Suk
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.374-385
    • /
    • 2012
  • The indoor noise of a ship is usually determined using the A-weighted sound pressure level. However, in order to better understand this phenomenon, evaluation parameters that more accurately reflect the human sense of hearing are required. To find the level of the satisfaction index of the noise inside a naval vessel such as "Loudness" and "Annoyance", psycho-acoustic evaluation of various sound recordings from the naval vessel was performed in a laboratory. The objective of this paper is to develop a single index of "Loudness" and "Annoyance" for noise inside a naval vessel according to a psycho-acoustic evaluation by using psychological responses such as Noise Rating (NR), Noise Criterion (NC), Room Criterion (RC), Preferred Speech Interference Level (PSIL) and loudness level. Additionally, in order to determine a single index of satisfaction for noise such as "Loudness" and "Annoyance", with respect to a human's sense of hearing, a back-propagation neural network is applied.

공기조화기용 열교환기의 공기측 파울링 입자 분석 연구 (Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

함정의 실내소음 허용기준 설정을 위한 청감평가 및 분석 (Psycho-acoustic Evaluation and Analysis of the Indoor Noise in Cabins of a Naval Vessel to Specify its Allowable Limit)

  • 홍현수;심상렬;한형석
    • 한국소음진동공학회논문집
    • /
    • 제21권7호
    • /
    • pp.650-656
    • /
    • 2011
  • The noise inside a naval vessel is very important in considering the need for hearing protection, improving the working environment and maintaining good communications for crews living on board a naval vessel. The indoor noise of a ship usually is specified by the A-weighted sound pressure level, but other evaluating parameters are required to reflect human senses more effectively. This paper uses additional noise indices related to room acoustics, such as NR(noise rating), NC(noise criterion), RC(room criterion), PSIL(preferred speech interference level) and loudness level to evaluate the noise inside cabins on a naval vessel. Using these psychological noise indices, allowable limit of noise level in cabins is suggested through psycho-acoustic evaluation for the noise in cabins.

개구부를 통한 외부압력 변동에 의한 난류환기 모델링 (Modeling of Turbulent Ventilation through an Opening due to Outdoor Pressure Fluctuations)

  • 한화택;염철민
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.121-127
    • /
    • 2008
  • This paper investigates the effects of outdoor pressure fluctuations on natural ventilation through an opening on a building envelope. The ventilation airflow rate depends on the magnitude and the period of the pressure fluctuations, the size of the opening relative to the space volume, and the resistance characteristics of the opening. Non-dimensional parameters have been derived, which determine indoor pressure responses due to outdoor pressure fluctuations. The flow regions are categorized into (1) synchronized region, (2) opening resistance region, and (3) transition region depending on the non-dimensional parameter derived. Pressure fluctuations and flow characteristics are investigated numerically using the 4th order Runge-Kutta method.

휴리스틱 기법을 이용한 비통신 인버터형 냉장시스템의 성능개선 알고리즘 개발 (Heuristic Algorithm for Performance Improvement of Non-Communication Inverter Type Refrigerator)

  • 민선규;김형준;이주경;황준현;이석
    • 한국정밀공학회지
    • /
    • 제34권2호
    • /
    • pp.133-138
    • /
    • 2017
  • Inverter-Type refrigerators are known to consume less energy by varying the inverter frequency according to indoor temperatures and refrigerant pressure through indoor-outdoor communication. However, many commercial operators cannot afford to replace indoor units with ones capable of communication. In a non-communication configuration, indoor units are connected with an inverter-type outdoor unit without intercommunication abilities. The research goal is finding appropriate operating parameters to achieve energy efficiency. Thus, an operation algorithm with two modes is proposed, i.e., one to search the best operating parameters and one for normal operation with the best parameters. The experimental evaluation showed 11.27% reduction in energy consumption, indicating a good applicability of the algorithm.

공간크기에 따른 로켓모타 충격소음의 비교분석에 관한 연구 (A Study of the Comparison Analysis for the Rocket Motor Impulse Noise by the Indoor Sizes)

  • 송기혁;정성학;강우람;이덕주;박종호
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.85-90
    • /
    • 2014
  • The purpose of this study is to analysis the 3 differential size of the interior space for impulse noise. To achieve this goal the 3 kinds (27, 35, $50m^3$) of interior space were performed comparing the impulse noise. Result of this study, the standard error of the mean peak sound pressure of value from 0.19 to 0.27dB and there was no significant difference (p<0.01). And B-duration is significant differences (P<0.01) range from 3.98 to 7.93ms. This is respectively less than 10ms. These findings are confirmed in accordance by the 3 differential space size of the indoor-impulse noise due to 0.3 dB or less, so there was no difference to the operational influence. And also below 100 Hz were found fundamental mode frequency analysis. Results were matched with calculated theoretical values.