• Title/Summary/Keyword: Indoor Particulate Matter

Search Result 114, Processing Time 0.03 seconds

A Study on the Research Topics and Trends in South Korea: Focusing on Particulate Matter (토픽모델링을 이용한 국내 미세먼지 연구 분류 및 연구동향 분석)

  • Park, Hyemin;Kim, Taeyong;Kwon, Daewoong;Heo, Junyong;Lee, Juyeon;Yang, Minjune
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.873-885
    • /
    • 2022
  • The particulate matter (PM) has emerged as a hot topic around the world as it has been reported that PM is related to an increase in mortality and prevalence rates. In South Korea, the importance of PM has been recognized since the late 1990s, and various studies on PM have been conducted. This study investigated the PM research topics and trends for papers (D=2,764) published in Research Information Sharing Service (RISS) using topic modeling based on Latent Dirichlet Allocation (LDA). As a result, a total of 10 topics were identified in the whole papers, and the PM research topics were classified as 'PM reduction (Topic 1)', 'Government policy and management (Topic 2)', 'Characteristics of PM (Topic 3)', 'PM model (Topic 4)', 'Environmental education (Topic 5)', 'Bio (Topic 6)', 'Traffic (Topic 7)', 'Asian dust (Topic 8)', 'Indoor PM (Topic 9)', 'Human risk (Topic 10)'. In particular, the proportion of papers on topics 'Government policy and management (Topic 2)', 'PM model (Topic 4)', 'Environmental education (Topic 5)', and 'Bio (Topic 6)' to the toal number of papers increased over time (linear slope > 0). The results of this study provide the new literature review methodology related to particulate matter and the history and insight.

A Case Study on Distribution Characteristics of Indoor and Outdoor Particulate Matter (PM10, PM2.5) and Black Carbon (BC) by Season and Time of the Day in Apartments (아파트 실내·외 미세먼지(PM10, PM2.5)와 블랙카본(Black Carbon)의 계절별 농도 및 시간대별 분포 특성 사례연구)

  • Park, Shinyoung;Yoon, Danki;Kong, Hyegwan;Kang, Sanghyeon;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.339-355
    • /
    • 2021
  • Background: Particulate matter (PM10, PM2.5) and black carbon contribute to poor air quality in urban areas, and can also affect indoor environments. Exposure to PM can be associated with respiratory and lung diseases. Objectives: This study investigated the indoor and outdoor concentration distribution patterns of PM10, PM2.5, and black carbon at an apartment building, a typical residential space in the metropolitan areas of South Korea, by season, day of the week (weekday vs. weekend), and time of the day. It aims to obtain foundational data for the effective management of pollutants and investigate the difference in pollution levels between indoor and outdoor environments. Methods: Indoor and outdoor concentrations of PM and black carbon were measured at an apartment building located in Namyangju, Gyeonggi-do Province, using dust sensors and an Aethalometer AE51 (AethLabs, San Francisco, CA, USA) over the course of a year from June 2020 to May 2021. The concentration distribution patterns were analyzed by season and time of day. Results: PM10 and PM2.5 concentrations in the outdoor environment were higher than those in the indoor environment, regardless of the season. By contrast, the indoor black carbon concentration was higher than that in the outdoor environment during summer and autumn. The concentrations of PM10, PM2.5 and black carbon were found to be higher on weekdays than during weekends, especially during rush hour, with concentrations of 25.92~56.58 ㎍/m3, 21.12~44.82 ㎍/m3, 0.63~3.40 ㎍/m3. Conclusions: The outdoor concentrations of PM10, PM2.5, and black carbon were higher during the weekdays, especially during rush hour, than during weekends. This study is expected to provide basic data for the health management of apartment occupants because it is measured over a period of more than one year.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at Kwangju Area

  • Son, Bu-Soon;Song, Mi-Ra;Yang, Won-Ho;Chung, Young-Dall;Pack, Jong-An
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.373-377
    • /
    • 2005
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals and from chemicals are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCS and particulate matter($PM_{10}$) during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and PM lo were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor sources and outdoor sources. Therefore, proper management methods should be taken to improve the indoor air quality in beauty shops.

  • PDF

Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles - (도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 -)

  • Baek Sung-Ok;Park Sang-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room (음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화)

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Pre-study for the improvement of air filtration performance in the air handling unit of subway station (도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구)

  • Kang, Joong-Goo;Shin, Chang-Heon;Bae, Sung-Joon;Kwon, Soon-Bark;Kim, Se-Young;Han, Seok-Yoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF

A Study on Particulate Matter Reduction Effects of Vegetation Bio-Filters by Airflow Volume (공조풍량별 식생바이오필터의 입자상 오염물질 저감효과 연구)

  • Choi, Boo Hun;Kim, Tae Han
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.89-95
    • /
    • 2021
  • As the influence of fine dust on society spreads gradually, the public's interest in indoor air is increasingly rising. Air-purifying plants are drawing keen attention due to their natural purifying function enabled by plant physiology. However, as their fine dust reduction mechanism is limited to adsorption only, vegetation bio-filters that optimize purification effects through integration with air-conditioning systems is rising as an alternative. In accordance with the relevant standard test methods, this study looked into the fine dust reduction assessment method by air-conditioning airflow volume that can be used for the industrial spread of vegetation bio-filters. In the case of PM10 at 300 ㎍/m3, it was in the order of EG-B(3,500CMH, 29 min.) < EG-A (2,500CMH, 37 min.) < CG(0CMH, 64 min.) for reaching the maintenance level (100 ㎍/m3) of publicly used facilities. For reaching the WHO Guideline(50 ㎍/m3) requirement, it was in the order of EG-B (51 min.) < EG-A (160 min.) < CG (170 min.). In the case of PM2.5, it was in the order of EG-B (26 min.) < EG-A (33 min.) < CG (57 min.) for reaching the maintenance level (50 ㎍/m3) of publicly used facilities. It was in the order of EG-B (48 min) < EG-A (140 min) < CG (158 min) for reaching the WHO Guideline (25 ㎍/m3) requirement. The findings from the analysis showed that fine dust can be reduced most efficiently when the system is operated at 3,500CMH level. The limitation of this study is that due to the absence of a way of assessing the stress of plants in vegetation bio-filters, generating optimal air-conditioning air flow of the relevant system and economics analysis against the existing facility-type air purification system have been clarified, which should be explored further though follow-up studies.

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

A Suggestion of indoor CO2 concentration prediction equation by operating KTX flap in Tunnel Sections (터널구간 운행시 KTX 플랩 작동에 따른 CO2 농도 예측식 제안)

  • So, Jin-Sub;Yoo, Seong-Yeon;Kim, Ick-Hee
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2052-2057
    • /
    • 2010
  • In December 2006, the Ministry of Environment in Korea established the "Indoor Air Quality Management Guidelines in Public Transportation." As the items of the guideline, $CO_2$(Carbon dioxide) and PM10(Particulate matter). Therefore, the air quality inside the train is supposed to be ruled by this guideline. This study calculated the increase or decrease rate of the $CO_2$ concentration by using the data measured in accordance with flap operation. In case of flap close or open, the calculated $CO_2$ concentration variation was 6.32ppm/min. The $CO_2$ concentration prediction equation was derived from the general equation and the actual measured value are compared with the predicted $CO_2$ concentration suggested during the KyungBu high speed railway construction. The predicted value show good agreement with the measured data.

  • PDF