Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

철도 전동차내의 실내공기질 평가 - 온도 및 습도를 중심으로 - (Evaluation of Indoor Air Quality in the Railroad Electric Rolling Stock - Focused on Temperature and Humidity -)

  • 박덕신;배상호;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.610-615
    • /
    • 2003
  • Electric rolling stock is one of major public transportation because of an increase in population and heavy traffic problems. The passengers under the influenced of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system on passenger cars should be designed for the health and comfort of the passengers. One of the main aim is to create an acceptable thermal environment without draught problems. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in passenger cars is turbulent. Lateral temperature and humidity gradients in the electric rolling stock have been studied. And, the difference in the mean temperature and relative humidity measured at 0.7, 0.9, 1.2, 1.7 m above from the floor.

  • PDF

A Study on the Perception Level and Proper Management of Indoor Air Quality Recognition in Elderly Care Hospital Workers

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.171-178
    • /
    • 2019
  • 본 연구에서는 노인요양병원의 실내공기질 관리계획을 제안하고자 노인요양병원의 실내공기질 수준을 측정하고 근무자의 실내공기질에 대한 인식에 대하여 조사하였다. 측정 항목은 온도, 습도, CO2, CO, PM10, VOC이며 2019년 4월 26일에 실시하였다. 설문 조사에 따르면 실내 공기질에 대한 만족도가 낮을수록 실외 공기질이 더 좋다고 응답하였으며 실내환경 요소 중 악취가 가장 낮은 것으로 응답하였으며 실내 공기질의 만족도가 높을 경우 실내환경 요소의 만족도도 높은 것으로 분석되었다. 다중응답 분석결과 "환기 부족"이었고 회귀 분석 결과 "공기질 관련성" 항목이 가장 낮은 것으로 분석되었다. 노인 요양 병원의 실내 공기질 환경을 최고 수준으로 유지하려면 냄새를 제거하기 위한 환기 장지를 추가로 설치하고 자연 환기 횟수를 늘리고 정기적인 환기담당자를 지정해야 할 것으로 판단된다. 이러한 계획을 수립함으로써 노인요양병원 근무자에게 최상의 서비스를 제공하기 위한 실내 공기질 환경을 제공 할 수 있다.

페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가 (Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone)

  • 박병윤;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

아파트의 겨울철 실내온열환경 실태와 생활요인 분석 (Analysis on Living Factor and Actual State of Indoor Thermal Environment in Apartment Units during Winter)

  • 최윤정;정연홍
    • 한국주거학회논문집
    • /
    • 제19권4호
    • /
    • pp.97-105
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor thermal environment in apartment units and to analyze the relationship between the living factors and indoor thermal elements. The field surveys consisted of measurements of physical elements and observations of living factors. In addition, the residents of 20 apartment units were interviewed to survey their subjective response. Field surveys were carried out from January to March 2007. Measuring elements were air temperature, globe temperature, and relative humidity. The results showed that the average of indoor temperature for the houses was $21.2{\sim}27.2^{\circ}C$, while 4 houses exceeded the comfort zone. The average of globe temperature for the houses was $21.3{\sim}27.5^{\circ}C$, while 6 houses exceeded the comfort zone. The mean relative humidity was $19.5{\sim}58.8%$, which is a relatively dry condition. The residents' average clothing value was $0.39{\sim}0.89$ clo(average 0.68 clo). The average thermal sensation vote on each room was $4.2{\sim}4.8$, which is 'neutral' to 'slightly warm'. Living factors had significant effect on indoor temperature in regression analysis were ventilation time(outdoor air exchange), opening time of door through balcony, and gas cooker use time.

아파트의 겨울철 실내온열환경 실태와 생활요인 분석 (Analysis on Living Factor and Present Condition of Indoor Thermal Environment in Apartment Units during Winter)

  • 최윤정;정연홍
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • The purposes of this study were to make clear the present condition of indoor thermal environment in apartment units and to analyze the relation of the living factors with indoor thermal elements. The field surveys consisted of measurements on physical elements and observations on living factors and interview on resident's subjective responses were carried out in 20 apartment units. The field surveys were carried out during the $January{\sim}March$ 2007. Measuring elements were air temperature, globe temperature, and relative humidity. As results, the averages of indoor temperature each houses were $21.2{\sim}27.2^{\circ}C$, the number of houses exceed the comfort zone were 4. The averages of globe temperature each houses were $21.3{\sim}27.5^{\circ}C$, 6 houses exceeded the comfort zone. The means of relative humidity were $19.5{\sim}58.8%$, relatively dry condition. The clothing value of residents were $0.39{\sim}0.89$ clo(average 0.68 clo). The average of thermal sensation ratings each room were $4.2{\sim}4.8$, 'neutral'$\sim$'slightly warm'. The results of regression analysis on relations of living factors with the thermal elements are as follow; ventilation time(outdoor air exchange), door opening time with balcony, and gas cooker use time had significant effect on indoor temperature.

  • PDF

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.

실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구 (Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment)

  • 윤동원;강효석;안병욱
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가 (Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles)

  • 이진형;김유재;최원석;박성관;윤백;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.