Characterization of Volatile Organic Compounds Emission from Interior Materials of Railway Passenger Cabin (철도차량용 내장재의 휘발성유기화합물 방출특성 분석)

  • Cho, Young-Min;Park, Duck-Shin;Kwon, Soon-Bark;Park, Eun-Young
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.182-187
    • /
    • 2008
  • The environmental significance of indoor air quality is gaining more attention. Especially, the contamination of indoor air by volatile organic chemicals (VOCs) has become a serious environmental concern. We investigated the VOCs emissions from some interior materials used in the conventional railway passenger cabin. The seat cover and the flooring of cabins were used as testing materials, and they were put in a clean environmental chamber. The temperature and relative humidity was kept at $25{\pm}1^{\circ}C$ and $50{\pm}5%$, respectively. It was found that these interior materials emitted significant amount of VOCs under constantly ventilated condition. The flooring emitted more halogenated VOCs than the seat cover, because it is made of PVC, which contains many chlorine atoms. However, the emission gradually decreased over time. Because the VOCs emission from interior materials may threaten the health of passengers in the cabin, interior materials emitting less VOCs should be used.

Development of a Natural Ventilation Model in a Single Zone Building with Large Openings (큰 개구부를 가진 단일구획 빌딩에서의 자연환기 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.359-369
    • /
    • 2018
  • A model has been developed to predict natural ventilation in a single zone building with large openings. This study first presents pressure-based equations on natural ventilation, that include the combined effect of wind and thermal buoyancy. Moreover, the concept of neutral pressure level(NPL) is introduced to consider the two-way flow through a large opening. The total pressure differences across the opening and the NPL are calculated, and nonlinear equations are solved to find the zonal pressure to satisfy mass conservation. For this analysis, an iterative technique of successively approximating the zonal pressure is used. The results of applying this study model to several simple cases are as follows. When there is no wind and only the stack effect is caused, a one-way flow occurs in both the top and bottom openings in the case of two openings of equal-area, and a one-way flow occurs in the top opening; however, a two-way flow occurs in the bottom opening in the case of two openings of unequal-area. When there is a wind effect, regardless of whether the outside air temperature is lower or higher than the indoor air temperature, air flows into the room through the bottom opening and out of the room through the top opening. As the wind velocity increases, the wind effect appears to be more influential than the stack effect owing to the temperature difference.

A Prediction of VOCs Emission Rate with Temperature Variation in Floor Heating Space by Numerical Analysis (수치해석에 의한 바닥난방공간의 온도변화에 따른 VOCs 방출속도 예측)

  • Kang, Dong-Hwa;Choi, Dong-Hee;Kim, Sun-Sook;Kim, Young-Don;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.468-476
    • /
    • 2006
  • The paper deals with the numerical analysis of contaminants emission from the material affected by temperature variation in floor heating system. Considering mass transfer and heat transfer theories, a computer program for the analysis of VOCs emission was made. To demonstrate the accuracy of the numerical solution, the prediction results and the measured data were compared. Using this program, emission rates of the materials in the bakeout space and the no bake-out space were compared to estimate the variation of emission rate.

Numerical Simulation of the Thermal Environment inside an Opened Tomb (개방된 고분내부의 열 환경 수치모사)

  • Lee, Kum-Bae;Youn, Young-Muk;Jun, Hee-Ho;Park, Jin-Yang;Ko, Seok-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.872-878
    • /
    • 2006
  • In recent years the importance of the preservation of cultural artefacts like ancient tombs has been widely accepted domestically and internationally as the quality of life improves. However not much technical attention has been paid for the facilities and systems to preserve those artefacts. Even the general understanding of the preservatory environment of the underground space as tombs is poor. As a part of the present study, the temperature and relative humidity inside a selected artefact, Shinkwan-ri tomb, have been monitored for a year round by the present author to improve the understanding of the indoor thermal environment, is pursued to provide a predictive tool of numerical modelling of Shinkwan-ri tomb the opened underground space thermal environment. In this study, predictive numerical modelling of Shinkwan-ri tomb using the Computational Fluid Dynamics, calculate the velocity and temperature distribution and offer basic data which are necessary for the best fitted design of tomb air-conditioning device.

  • PDF

A Study on the Characteristics of Heating and Cooling Loads of Standard Chicken Houses in South Korea (국내 표준계사의 냉난방부하 특성 연구)

  • Kwon, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.235-243
    • /
    • 2019
  • In South Korea, millions of poultry have died due to repeated heat waves every year. The purpose of this study is to analyze the characteristics of heating and cooling loads of chicken houses in Korea and to present an effective insulation and ventilation measures to minimize the damage of poultry due to summer heat wave and to save energy in chicken houses in winter. The heating and cooling loads of standard chicken house were calculated. As a result of the calculation of maximum heating load based on the minimum ventilation rate in winter, the outdoor air temperature requiring heating was $6{\sim}7^{\circ}C$ to keep the indoor air temperature of chicken houses as $24^{\circ}C$. The peak cooling load of chicken houses was mostly taken by the heat generated by chickens and the heat gain due to ventilation. The heat gain through building envelopes was as small as neglectable. Most of chicken houses is usually cooled by gigantic forced ventilation in summer in Korea. When the chicken houses are cooled by electric cooling machine such as cooler or air conditioner, it is more effective to keep minimum ventilation rate to reduce the maximum cooling load. To lower the temperature of supplying water to cooling pad, it is recommended to use the underground water below 10 meters from the ground if there is abundant underground water.

Studies on Effects of Interior Plantscaping as Related to the Air Ions (공기이온으로 본 실내녹화 효과에 관한 연구)

  • Kim, Tae-Soon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.3
    • /
    • pp.1-8
    • /
    • 2003
  • This study was carried out in order to investigate of effects of environmental conditions which influence negative ions development. Negative ions are nature' most powerful air-cleaning agents, are created by nature, and found at their most optimal levels where the air is most pure and healthy. Negative ions are regarded as one of the important factors which indicate the quality of the air. Therefore, the focus of this study was to clear relationship among negative ions development induced by plant cultivar and environmental conditions such as air temperature, light intensity and relative humidity. As the results of this study, it was found that negative ions development was promoted during the period with plants compared to the period without plants. In Particular, negative ions development was high under air temperature $20^{\circ}C$, relative humidity 90% and dark condition. Temperature and humidity factors on this experiment was strongly affected on negative ions development, but light intensity had almost slight effect. It was shown that these results can contribute to the application of environmental control techniques to negative ions. Among plant cultivar of Spathiphyllum spp. Mentha spicata, and Cupressu arizonica, Mentha spicata was higher negative ions than the other plants, and also the leaves were higher than the stems and roots. The effect of plants on the perception of the inte끼r air quality may, therefore, be one explanation of this results about negative ions. on the other hand, it seems that a green indoor environment might be an increase in general well-being due to the plants.

Formaldehyde Emissions and Moisture Content Change of Wood Composites during Bake-out

  • Lee, Young-Kyu;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.101-109
    • /
    • 2012
  • Wood composites are a hygroscopic material and have ability to exchange its moisture content with air. This study investigated the formaldehyde emission and moisture content change of four wood composites (particleboard (PB), medium density fiberboard (MDF), high density fiberboard (HDF), laminated HDF (L-HDF)) as a function of bake-out temperature and time. The composites were baked out for 1, 3, 5, 7, 10, 14, 21, and 28 days at temperatures of $20{\pm}2$, $35{\pm}2$, and $50{\pm}2^{\circ}C$ in a dry oven. The moisture content change was used to determine the emission bake-out of the composites. Best bake-out time results were obtained with after 7 days all composites. Formaldehyde emission values of composites decreased with decreasing moisture content for both temperatures. The formaldehyde emission results of bake-out temperature 35 and $50^{\circ}C$ showed a similar tendency.

Method and Analysis of Dynamic Simulation for Ondol Heating (온돌 난방에 대한 동적 시뮬레이션 및 분석)

  • Hong, Hi-Ki;Kim, Si-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

Analysis and Improvement of Cooling System for Energy Saving in Data Center Building (데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안)

  • Jung, Yong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses (공동주택용 온수난방 시스템의 에너지해석 및 제어특성)

  • 장효환;안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF