• Title/Summary/Keyword: Indoor Air Quality

Search Result 1,007, Processing Time 0.03 seconds

A Health Performance Evaluation Model of Building Indoor Air Quality (실내공기질의 건강성능 평가모델 연구)

  • ZHENG, QI;Lee, Dong-Hoon;Choi, Jae Hwi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.3-10
    • /
    • 2010
  • As indoor air quality directly affects health and comforts of the residents, researchers from different countries have continued to explore criteria by which indoor air quality can be indicated in a scientific and quantitative manner over the past several decades. However, there are many possibilities that can deteriorate indoor air quality. Due to the uncertainty of influence factors, it is quite difficult to develop a correct evaluation model and quantitative method. Furthermore, the effects from the indoor air pollutants have different levels, leading to the difficulties to apply the regular standard. This study aims to propose evaluation criteria by using the FD-AHP analysis. Obtained findings will be beneficial to construct apartment buildings, commercial buildings and others health performance evaluation framework.

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model (실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

A study on university office worker's perception of indoor air quality (Focused on K university) (사무실 근로자들의 실내공기질 인식에 관한 기초 조사 (K대학교를 중심으로))

  • Shin, Eun-Young;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.3
    • /
    • pp.69-76
    • /
    • 2017
  • Indoor Air Quality(IAQ) affects physical and mental state of person who is residing indoor. Also, it manages daily life condition of Indoor Air in the building. According to the study, office workers spend 23 hours and 12 minutes, about 97% of his/her day indoor. Therefore, Indoor air quality affects not only the health of the person whose staying inside for a long hours but also the productivity and efficiency of work. This study conduct investigations on employees' awareness of indoor air quality of office in university. By doing so, we are able to determine current situation and provide basic data of improvement for derived problems. As a result, most of the respondents were not satisfied with ventilation and moisture which are elements of Indoor Air Quality. These led people to struggle with symptoms of health. Therefore, to improve the indoor air quality of a university office, it is necessary to exchange the air six times an hour according to recommendation of Refrigeration and Air Conditioning Engineers (ASHRAE)in the United States. Also, plan for Ventilation system that consider temperature, humidity and air flow indoor shall be provided for high quality conformability. furthermore, It is necessary to consider the multilateral in factors of generation of revenue through health care savings of workers and improvement of productivity.

The Measurement of the Indoor Air Quality in Subway (전동차의 실내 공기청정도 측정 평가)

  • So, Jin-Sub;Yoo, Seong-Yeon;Yun, Cha-Jung;Kim, Wan-Jong;Kang, Sung-Hae;Park, Duk-Sin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1325-1329
    • /
    • 2007
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is established "Indoor Air Quality Management guidelines in Public Facilities"in December 2006. Hereupon, the train and the subway are included. In this research air quality in the Subway compartment has been measured. As a result, the concentrations of PM10 and $CO_2$ were reached to 93% and 61% of the regulation values, respectively. Thus, the indoor air qualities of subway have been proved that they satisfy the recommended guidelines by the Ministry of Environment.

  • PDF

A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

Perceived Air Quality Assessment of Occupants According to Indoor Air Quality (실내공기질에 따른 재실자의 인식성 공기질 평가)

  • Woo, Byung-Lyul;Lee, Hyun-Su;Ahn, Ho-Gi;Jung, Soon-Won;Hwang, Moon-Young;Park, Choong-Hee;Yu, Seung-Do;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

Temporal Variation of Indoor Air Quality in Daycare Centers (어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가)

  • Kim, Yoonjee;Lee, Sewon;Ban, Hyunkyung;Cha, Sangmin;Kim, Geunbae;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

Properties of Adsorption Matrix for Improving Indoor Air Quality using Cork (코르크를 활용한 실내공기질 개선용 흡착 경화체의 특성)

  • Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.56-57
    • /
    • 2019
  • Recently, the risk of fine dust is emerging in Korea. According to the OECD report, the incidence of hospitalization and mortality from lung disease is increased, and the incidence of lung cancer and mortality from ischemic heart disease with prolonged exposure are increased. In addition, indoor air quality has become an important factor affecting the human body as indoor life has increased due to the Industrial Revolution. Air pollutants that cause indoor air deterioration typically include particulate dusts as described above, formaldehyde and VOCs released in gaseous form from adhesive wood products used in building materials and furniture. May cause breathing problems. In this study, we analyzed the properties of adsorption matrix for improving indoor air quality using cork.

  • PDF

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF