• Title/Summary/Keyword: Indoor Air Control

Search Result 455, Processing Time 0.031 seconds

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Airborne Bacteria Concentration and Species Identification in Residential Living Spaces (주택내 주거공간에 따른 부유세균 농도 분포 및 종 동정 연구)

  • Kim, Sung-Yeon;Jheong, Weonhwa;Hwang, Eun-Seol;Kim, Ji-Hye;Jung, Joon-Sig;Lee, Jae-won;Chung, Hyen-Mi;Kwon, Myunghee
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.6
    • /
    • pp.438-449
    • /
    • 2016
  • Objectives: Exposure to airborne bacteria is associated with adverse health effects such as respiratory and infectious diseases. This study evaluated airborne bacterial concentrations in the living rooms, kitchens, and toilets of 30 homes. Methods: Bacteria were sampled with an MAS100 impactor in three spaces in the subject homes between April 2014 and February 2015. Bacteria were grown on TSA plates for 48 hours at $35^{\circ}C$. The bacterial strains were isolated and amplified by polymerase chain reaction. Results: The most culturable bacteria were found in toilets ($624.0CFU/m^3$, GM: $417.3CFU/m^3$), followed by in the kitchen ($503.8CFU/m^3$, GM: $324.9CFU/m^3$). The dominant genera identified were: Staphylococcus sp.(19%), Micrococcus sp.(16%), and Bacillus sp.(11%) in the indoor air and Bacillus sp. (30%) in the outdoor air. Gram-positive bacteria comprised more than half of all colonies. Conclusion: In this study, culturable bacteria concentrations were higher than those reported in other spaces. Therefore, it is important to control relative humidity and remove moisture to prevent bacteria from multiplying. Additionally, the dominant species in indoor air were Staphylococcus sp. and Micrococcus sp. These are found on the human skin, mucous membranes, and hair, so human activity can affect bacterial distribution. Therefore, cleaning and controlling moisture are important for reducing indoor bacterial concentrations.

An experimental study on the optimal control algorithm for central heating system (중앙난방 시스템의 최적제어 알고리즘의 적용을 위한 실험적 연구)

  • Ahn, Byung-Cheon;Chun, Won-Ik
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.463-468
    • /
    • 2005
  • An experimental study on the optimal control algorithm for central heating system for minimizing energy consumption while maintaining the comfort of indoor thermal en vironment in terms of the environmental variables such as loads and weather. experimental study has been done by one using the prototype of central heating system. As a result the optimal control algorithm shows good energy performance in comparison with conventional control one.

  • PDF

Optimal air-conditioning system operating control strategies in summer (여름철 공조시스템의 최적 운전 제어 방식)

  • Huh, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

Submerging Performances of Automatic Submersible Buoy Operated by Air Control (공기 제어에 의한 자동 부침 부자의 부침 성능)

  • Kim, Tae-Ho;Hur, Jung-Gyu;Yang, Kyong-Uk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.743-749
    • /
    • 2010
  • The primary object of this study was to develop the control algorithm and program for automatic submersible buoy which is free to move vertically within the water column by adjusting weight and buoyancy forces by air control. The experiment was performed to validate the usefulness of the program in the indoor water tank. In the experiment, the automatic submerging and surfacing of the buoy were controlled by water-pressure gauge and air control system. The buoy is raised by injecting compressed air from a compressor and then is lowered by releasing the air. The submerging and surfacing characteristics of the buoy calculated with the numerical model were similar to measurements obtained with the experiment. It was concluded that the algorithm and program could be useful in analyzing various parameters and submerging mechanisms required to design new type of automatic submersible fish cage system.

A Study of Environment Monitoring System based on Sensor Network (센서 네트워크를 이용한 실내 공기질 관리 및 제어에 관한 연구)

  • Kim, Ki-Tae;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.389-392
    • /
    • 2010
  • The problem for the air pollution in the office or the indoor except a specific working area is the continuously issue since the human beings have lived in the dwelling facilities. Measures for that problem are urgently needed. It's possible to solve for the freshair of outside with enough ventilation but that is the awkward situation to be managed by person. It's feasible to supervison and control easily if you use to sensor network under the network. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. This study compose a IAQM(Indoor Air Quality Management) under the network, suggest the application of supervision and control.

  • PDF

Dynamic Models and Intelligent Control Algorithms for a $CO_2$ Automotive Air Conditioning System (자동차 $CO_2$ 냉방시스템의 동적모델과 지능제어알고리즘)

  • Han, Do-Young;Jang, Kyung-Chang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.49-58
    • /
    • 2006
  • In the respect of the environmental protection viewpoint, $CO_2$ may be one of the most attractive alternative refrigerants for an automotive air-conditioning system. For the development of control algorithm of a $CO_2$ automotive air-conditioning system, characteristics of a $CO_2$ refrigerant should be considered. The high-side pressure of a $CO_2$ system should be controlled in order to improve the system efficiency. In this study, dynamic physical models of a $CO_2$ system were developed and dynamic behaviors of the system were predicted by using these models. Control algorithms of a $CO_2$ system were also developed and the effectiveness of these algorithm was verified by using dynamic models.

Identification and Concentration of Airborne Microbes in Food Manufacturing Plants (식품제조공장 내 공중부유미생물 오염도와 오염진균동정)

  • Gwak, Hyun-Jung;Lee, Hun-June;Lee, Sang-Ho;Na, Hye-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.361-365
    • /
    • 2011
  • To evaluate the indoor air quality of food manufacturing plants, the presence of viable bacteria and fungi was assessed in the indoor air of the facilities at which 9 food items were manufactured. Air samples were collected from the general zone, low clean zone and clean zone of each factory with an air sampler, in combination with plate counts agar using for bacteria, and dichloran-glycerol agar for fungi. The samples were incubated at $25^{\circ}C$ for 4 to 7 days. After culture, the colony forming units (CFU) on each plate were counted and corrected with a positive hole conversion table. The average concentration of bacteria was $2.2{\times}10^3\;CFU/m^3$ in the general zone, $1.2{\times}10^3\;CFU/m^3$ in the low clean zone and $7.3{\times}10^2\;CFU/m^3$ in the clean zone. The average concentration of fungal microbes was $2.5{\times}10^3\;CFU/m^3$ in the general zone, $2.6{\times}10^3\;CFU/m^3$ in the low clean zone, and $2.0{\times}10^2\;CFU/m^3$ in the clean zone. No meaningful differences were detected between the general zone and the low clean zone, but the clean zone had significantly lower concentrations than the other zones. Additionally, the identification of the fungi was performed according to morphological method using a giant culture and slide culture. The fungi were identified as belonging to 18 genera, and the genera Cladosporium(33%), Penicillium(29%) and Aspergillus(26%), predominated. Aspergillus isolates were identified to species level, and A. ochraceus, a mycotoxigenic species, was identified. As part of the effort to control the quality of the indoor air of food manufacturing plants, our results show that continued studies are clearly warranted.

An Experimental Study on the Ventilation Characteristics of a Wind-Turbine Natural Ventilator According to the Outdoor-Wind Velocity and the Indoor/Outdoor-Temperature Difference (윈드터빈 자연환기 장치의 외기풍속 및 온도차에 따른 환기특성에 관한 실험연구)

  • Han, Dong-Hun;Kim, Yeong-Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • With the improvement of living standards, the ventilation for the mitigation of indoor or outdoor air-pollution problems has recently attracted a lot of attention. Consequently, the ventilation for the supply of outdoor fresh air into a room is treated as an important building-design factor. The ventilation is generally divided into the forced and natural types; here, the former can control the ventilation rate by using mechanical devices, but it has the disadvantages of the equipment costs, maintenance costs, and noise generation, while the latter is applied to most workshops due to the absence of noise and the low installation and maintenance costs. In this experimental study, the ventilation performance of a typical rotating-type natural ventilator, which is called a "wind turbine," was investigated with the outdoor-wind velocity and the indoor/outdoor-temperature difference. From the experiment results, it was confirmed that the temperature difference of $10^{\circ}C$ corresponds to the ventilation driving force with an outdoor-wind velocity of 1.0 m/s. Additionally, the intake-opening area of a building also exerts a great effect on the ventilation rates.

A Study of air Sterilization System in Personalized Office Using Simulation (시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구)

  • Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.