• Title/Summary/Keyword: Indoor $CO_2$ concentration

Search Result 181, Processing Time 0.026 seconds

Minimum Ventilation Rate of Kindergarten in the respect of IAQ (실내공기질을 고려한 유치원 보육실의 적정 환기량 검토)

  • Cheong, Chang-Heon;Lee, Yun-Gyu;Kim, Tae-Youn;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.283-288
    • /
    • 2006
  • Indoor Air Quality Guideline of Kindergarten in korea didn't consider the vulnerable properties of children to indoor air pollutants. For this reason, Suggestion for the IAQ guideline of formaldehyde and minimum ventilation rate was made in this study. Suggested IAQ guidelines for formaldehyde in the respect of children's vulnerable immune system is $30{\mu}g/m^3$ and $50{\mu}g/m^3$, and for the ventilation rate 11.9 ACH, 5.8 ACH, respectively. This value is based only formaldehyde and CO2 concentrations in child-care room of Kindergarten and needed to be verified by further investigations and studies. However it is discovered that lower formaldehyde concentration can do mal-effects to children's health by literature review.

  • PDF

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Cheong, Seong-Ir;Sheng, Nai-Li;Kim, Doo-Hyun;Lee, Jae-Keun;Hwang, Yu-Jin;Park, Jong-Hoon;Seo, Seok-Jang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Study on the Performance of a Short Term Ozone Passive Sampler in Experimental Chamber (단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구)

  • Jeong, Sang-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.8
    • /
    • pp.1001-1009
    • /
    • 2007
  • Passive sampler is a simple and cost-effective measuring equipment for ambient and indoor air pollution. We studied the performance of a short term (1 hour mean concentration) ozone passive sampler which was coated with a colorant (indigo carmine) to a filter substrate. Acetone and sulfamic acid added ozone passive sampler was investigated to measure short term mean ozone concentration. Ozone response and interference of criteria air pollutant($SO_2,\;NO_2$, CO) on a short term ozone passive sampler was tested through experimental chamber. The results show sulfamic acid added passive ozone sampler have good response in ozone exposure. Interference of $NO_2$ gas is larger than other two criteria gases.

Study on the Removal of Carbon Dioxide in the Subway Cabin Using Zeolite Type Carbon Dioxide Adsorbent (제올라이트계 이산화탄소 흡착제를 사용한 지하철 객실 내부의 이산화탄소 제거에 관한 연구)

  • Cho, Young-Min;Park, Duck-Shin;Kwon, Soon-Bark;Lee, Ju-Yeol;Hwang, Yun-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • High concentration of carbon dioxide at subway cabin is one of the serious environmental concerns because carbon dioxide causes drowsiness, headache, and nervelessness of passengers. Ministry of Environment set a guideline for indoor carbon dioxide levels in train or subway in 2007. In this study, a carbon dioxide removal system for subway cabin was developed and tested using a test subway cabin. Various types of modified zeolites were used as the adsorbent of carbon dioxide. The tested zeolites were applied to the subway cabin, and showed high potential to lower the indoor $CO_2$ level.

Welding Fume and Metals Exposure Assessment among Construction Welders (건설현장 용접직종별 용접흄 및 금속류 노출 실태)

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.147-158
    • /
    • 2016
  • Objectives: The objective of this study was to evaluate the assessment of exposure to welding fume and heavy metals among construction welders. Methods: Activity-specific personal air samplings(n=206) were carried out at construction sites of three apartment, two office buildings, and two plant buildings using PVC(poly vinyl chloride) filters with personal air samplers. The concentration of fumes and heavy metals were evaluated for five different types of construction welding jobs: general building pipefitter, chemical plant pipefitter, boiler maker, ironworker, metal finishing welder. Results: The concentration of welding fumes was highest among general building pipefitters($4.753mg/m^3$) followed by ironworkers($3.765mg/m^3$), boilermakers($1.384mg/m^3$), metal finishing welders($0.783mg/m^3$), chemical pipefitters($0.710mg/m^3$). Among the different types of welding methods, the concentration of welding fumes was highest with the $CO_2$ welding method($2.08mg/m^3$) followed by SMAW(shield metal arc welding, $1.54mg/m^3$) and TIG(tungsten inert gas, $0.70mg/m^3$). Among the different types of workplace, the concentration of welding fumes was highest in underground workplaces($1.97mg/m^3$) followed by outdoor($0.93mg/m^3$) and indoor(wall opening as $0.87mg/m^3$). Specifically comparing the workplaces of general building welders, the concentration of welding fumes was highest in underground workplaces($7.75mg/m^3$) followed by indoor(wall opening as $2.15mg/m^3$). Conclusions: It was found that construction welders experience a risk of expose to welding hazards at a level exceeding the exposure limits. In particular, for high-risk welding jobs such as general building pipefitters and ironworkers, underground welding work and $CO_2$ welding operations require special occupational health management regarding the use of air supply and exhaust equipment and special safety and health education and fume mask are necessary. In addition, there is a need to establish construction work monitoring systems, health planning and management practices.

Size Distribution and Concentration of Airborne Fungi in the Public Facilities (다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성)

  • Park, Jae-Beom;Kim, Ki-Youn;Jang, Gyu-Yeob;Kim, Chin-Yon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.36-45
    • /
    • 2006
  • The aim of this study is to examine size-based concentration and genera of airborne fungi distributed in public facilities such as hospital, kindergarten, day-care center and postpartum nurse center and to provide fundamental data in order to prevent respiratory diseases caused by exposure to airborne fungi. Culturable total and respirable concentrations of airborne fungi averaged to $382\;cfu/m^3\;and\;292\;cfu/m^3$ in hospital, $536\;cfu/m^3\;and\;347\;cfu/m^3$ in kindergarten, $334\;cfu/m^3\;and\;266\;cfu/m^3$ in day-care center, and $371\;cfu/m^3\;and\;289\;cfu/m^3$ in postpartum nurse center, respectively. The ratio of respirable to total concentration of airborne fungi in the investigated public facilities was ranged from $55\%\;to\;70\%$ but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.56 and 0.64 in hospital, 0.72 and 0.91 in kindergarten, 0.33 and 0.45 in day-care center, and 0.63 and 0.73 in postpartum nurse center, respectively. Indoor concentration of airborne fungi did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ concentration (p<0.01) and surrounding condition (p<0.05). Penicillium spp., Cladosporium spp., and Aspergillus spp. were estimated to over $95\%$ of total airborne fungi identified in the investigated public facilities.

Membrane-based Direct Air Capture Technologies (분리막을 이용한 공기 중 이산화탄소 제거 기술)

  • Yoo, Seung Yeon;Park, Ho Bum
    • Membrane Journal
    • /
    • v.30 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • As the demand for fossil fuels continues to increase worldwide, carbon dioxide (CO2) concentration in the air has increased over the centuries. The way to reduce CO2 emissions to the atmosphere, carbon capture and sequestration (CCS) technology have been developed that can be applied to power plants and factories, which are primary emission sources. According to the climate change mitigation policy, direct air capture (DAC) in air, referred to as "negative emission" technology, has a low CO2 concentration of 0.04%, so it is focused on adsorbent research, unlike conventional CCS technology. In the DAC field, chemical adsorbents using CO2 absorption, solid absorbents, amine-functionalized materials, and ion exchange resins have been studied. Since the absorbent-based technology requires a high-temperature heat treatment process according to the absorbent regeneration, the membrane-based CO2 capture system has a great potential Membrane-based system is also expected for indoor CO2 ventilation systems and immediate CO2 supply to smart farming systems. CO2 capture efficiency should be improved through efficient process design and material performance improvement.

A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Kim, Se-Hwan;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.