• Title/Summary/Keyword: Individual room control ventilation

Search Result 4, Processing Time 0.023 seconds

Feasibility Study on Installation of Individual Room Control Ventilation in Apartment House (공동주택의 실별 제어환기 도입 타당성 분석)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kwon, Yong-Il;Yun, Young-Woo;Cho, Chun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.502-507
    • /
    • 2009
  • Trend of mechanical ventilation system applied to apartment house is introduced and feasibility study on installation of the individual room control ventilation as energy-saving method is carried out through field experiment. While initial cost of installation for the individual room control ventilation increases, the running cost is lower than the individual household control ventilation due to automatic flow rate control and reduction of fan power, and the management cost also decreases due to extension of use life of components. As the results of field experiment on $115m^2$-type apartment house, the individual room control ventilation could save the amount of 1,459.5Wh/day when compared with the individual room control ventilation

  • PDF

Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems (개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.131-139
    • /
    • 2018
  • Many ship researches have been carried out in connection with the fourth revolution, one of which focuses on EMS(energy management system). The EMS is referred to as systems for managing the energy of ships and include various systems. In this paper, we analyze the energy saving field in ship and propose a ship power energy management system including individual load control systems that can save energy in the engine room. EMS includes individual load control systems of PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System). Proposed EMS primarily conserves energy in the individual load systems of the engine room. Secondly, the integrated monitoring and control system is used to control the power generation system and the power load system to save energy.

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

A Case Study on Active Usage of the Storage Space Outside Housing Unit of Residential Complex (공동주택 세대외부창고의 활성화 방안을 위한 사례 연구)

  • Song, Jihyun;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.58-67
    • /
    • 2018
  • This study aims to analyze the cases of storage space outside housing unit and propose the activation plan. The issue of storage in residential complex has continued to be reported. This is more salient due to the recent preference trend for small houses, the constant increase of living goods and the limitation of the available space inside housing unit. Although more apartment houses are trying to have individual storage in the exterior space to address these issues, there is still a paucity of the related studies and more studies are required. In this study, we conducted on-site investigation and user interview of each case to propose active usage of the storage space outside housing unit. Result of this study shows that the most crucial factor to improve is 'accessibility' in order to activate the storage space. Storage room should be located close to each household or the individual parking space. The second factor is the size and the structure of the storage room. The sufficient space for keeping and taking large objects out are required. The front of the storage room should have a clogged structure to insure privacy. The third is the provision of suitable support programs such as the system that occupants can check remotely what items are in their storage rooms, garage sale, laundry service, auto cleaning system and rental program. Those programs are required for efficient management and activation of space. Another requirement is to improve environmental factors which include maintenance of optimal temperature and humidity, automatic ventilation system, control of individual lights, and security enhancement. Based on the results of the survey, we provide basic data which can be used for practical space planning to activate exterior storage space of the housing unit. Further surveys are required to develop this study by obtaining more data for generalization.