• Title/Summary/Keyword: Indirect measurement

Search Result 449, Processing Time 0.034 seconds

A study on the estimation of river water intake using the operating time of the pumping station (양수장의 가동시간을 이용한 하천수 취수량 산정방안 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, Jun-Ho;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.89-96
    • /
    • 2020
  • Water management agencies under the Ministry of Environment produce and accumulate qualified basic data for major rivers. However, the integrated management of the river water has been weak since the artificial water circulation process, such as the intaking and drainage of agricultural water, has not been examined in the basin, which includes many agricultural land. In this study, a study was conducted on how the power usage method (operating time method) based on the running time can be applied and improved among indirect flow rate measurement methods used to investigate flow rates collected by the riverside for agricultural water purposes, and thus the resultant data of high reliability can be obtained at low cost. The operation time method is suitable for small-scale water pumping stations where it is difficult to secure real-time power supply data. The reliability of the data was verified through the correlation analysis with the actual flow rate, and it was found that the flow rate calculated by the operation time method reflecting the level of the stream to which the inlet of the pumping station is connected can be reasonably matched with the actual flow rate. In addition, it was confirmed that the investment cost at the time of initial installation of the facility was highly efficient by generating qualified flow data at low cost through comparison with direct flow rate measurement methods. If flow data is secured by applying the operation time method to large and small water farms located along the riverside, it is expected that more quantitative and integrated stream water management will be possible.

Development of Organic Fertilizer based on the Cow Dung III. Studies on Tentative Guideline for Degree of Maturity (우분(牛糞)의 유기질비료화(有機質肥料化) 연구 III. 부숙도(腐熟度) 기준설정(基準設定))

  • Lim, Dong-Kyu;Jeong, Lee-Geon;Shin, Jae-Sung;Han, Ki-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.4
    • /
    • pp.278-285
    • /
    • 1991
  • This study was conducted to manufacture a good qualified organic fertilizer with cow dung through rapid composting process, and the proposal guideline of the degree of maturity could be estimated with the measurement of final product. It included total nitrogen content of above 2% on an oven-dry material basis, C/N ratio of below 20, CEC of more than about 60 me/100g, ratio of carbon in reducing sugar to the total carbon of below 35%, and temperature in pile of above $60^{\circ}C$. The total nitrogen content, the C/N ratio, and the Paper Chromatographic method couldn't be the guideline to evalute the maturity of cow dung compost. CEC was increased in increased fermentation and it was high in the high fermented temperature plots which were cow dung+ shredded bark in 1988, cow+dung+wood chips in 1989, and cow dung+rice straws in 1990. The ratio of carbon in reducing sugar to total carbon in 1990 was lower in cow dung+saw dust than cow dung+rice straws that was the highest temperature in pile. Generally cow dung was mixed well with saw dust and thus the total carbon of the product was high. The measurement of the temperature in pile seems to be a indirect guideline of maturity.

  • PDF

Calibration Examination of Dose Area Product Meters using X-ray (X선을 이용한 면적선량계의 교정 연구)

  • Jung, Jae Eun;Won, Do-Yeon;Jung, Hong-Moon;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • We measured the absorbed dose and the area dose using an ionization chamber type of area dose product (DAP) meter and measured the calibration factor in the X-ray examination. In the indirect dose measurement method, the detector was installed in the radiation part of the X-ray equipment, and the measured value was calculated as the dose at the exposure part. The instrument used to calculate the calibration factor was an X-ray equipment (DK-550R / F, DongKang Medical Co., Ltd., Seoul, Korea). The calibration method for the calibration factor was to connect the DAP meter (PD-8100, Toreck Co. Ltd., Japan) to the calibration dosimeter tube voltage of 70 kV, tube current of 500 mA, 0.158 sec. The reference dosimeter used a semiconductor (DOSIMAX plus A, Scanditronix, $Wellh{\ddot{o}}fer$, Germany). After installing the DAP meter on the front of the multi-collimator of the ionization chamber, the calibration factor of the dosimeter was obtained using the reference dosimeter for accurate dose measurement. Experimental exposure values and values from the calibration dosimeter were calculated by multiplying each calibration factor. The calibration factor was calculated as 1.045. In order to calculate the calibration coefficient according to the tube voltage in the ionization type DAP dosimeter, the absorbed dose and the area dose were calculated and the calibration factor was calculated. The corrective area dose was calculated by calculating the calibration factor of the DAP meter.

Real-Time Monitoring of Mitochondrial ATP Synthesis and Hydrolysis by Surface Infrared Spectroscopy

  • Yamaguchi, Ryo-Taro;Hirano-Iwata, Ayumi;Aonuma, Yuki;Yoshimura, Yuya;Shinohara, Yasuo;Kimura, Yasuo;Niwano, Michio
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.108-109
    • /
    • 2013
  • Mitochondria play key roles in the production of cell's energy. Their dominant function is the synthesis of adenosine 5'-triphosphate (ATP) from adenosine diphosphate (ADP) and phosphate (Pi) through the oxidative phosphorylation. Evaluation of drug-induced mitochondrial toxicity has become increasingly important since mitochondrial dysfunction has recently been implicated in numerous diseases including cancer and diabetes mellitus. Mitochondrial functions have been monitored via oxygen consumption, mitochondrial membrane potential, and more importantly via ATP synthesis since ATP synthesis is the most essential function of mitochondria. Various analytical methods have been employed to investigate ATP synthesis in mitochondria, including high performance liquid chromatography (HPLC), bioluminescence technique, and pH measurement. However, most of these methods are based on destructive analysis or indirect monitoring through the enzymatic reaction. Infrared absorption spectroscopy (IRAS) is one of the useful techniques for real-time, label-free, and direct monitoring of biological reactions [1,2]. However, the strong water absorption requires very short path length in the order of several micrometers. Transmission measurements with thin path length are not suitable for mitochondrial assays because solution handlings necessary for evaluating mitochondrial toxicity, such as rapid mixing of drugs and oxygen supply, are difficult in such a narrow space. On the other hand, IRAS in the multiple internal reflection (MIR) geometry provides an ideal optical configuration to combine solution handling and aqueous-phase measurement. We have recently reportedon a real-time monitoring of drug-induced necrotic and apoptotic cell death using MIR-IRAS [3,4]. Clear discrimination between viable and damaged cells has been demonstrated, showing a promise as a label-free and real-time detection for cell-based assays. In the present study, we have applied our MIR-IRAS system to mitochondria-based assays by monitoring ATP synthesis in isolated mitochondria from rat livers. Mitochondrial ATP synthesis and hydrolysis were in situ monitored with MIR-IRAS, while dissolved oxygen level and solution pH were simultaneously monitored with O2 and pH electrodes, respectively. It is demonstrated that ATP synthesis and hydrolysis can be monitored by the IR spectral changes in phosphate groups in adenine nucleotides and MIR-IRAS is useful for evaluating time-dependent drug effects of mitochondrial toxicants.

  • PDF

A Study on Vector-based Converting Method for Hydrological Application of Rainfall Radar Image (레이더 영상의 수문학적 활용을 위한 벡터 변환방법 연구)

  • Jee, Gye-Hwan;Oh, Kyoung-Doo;An, Won-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.7
    • /
    • pp.729-741
    • /
    • 2012
  • Among the methods of precipitation data acquisition, a rain gauge station has a distinctive advantage of direct measurement of rainfall itself, but multiple stations should be installed in order to obtain areal precipitation data required for hydrological analysis. On the other hand, a rainfall radar may provide areal distribution of rainfall in real time though it is an indirect measurement of radar echoes on rain drops. Rainfall radars have been shown useful especially for forecasting short-term localized torrential storms that may cause catastrophic flash floods. CAPPI (Constant Altitude Plan Position Indicator), which is one of the several types of radar rainfall image data, has been provided on the Internet in real time by Korea Meteorological Administration (KMA). It is one of the most widely available rainfall data in Korea with fairly high level of confidence as it is produced with bias adjustment and quality control procedures by KMA. The objective of this study is to develop an improved way to extract quantitative rainfall data applicable to even very small watersheds from CAPPI using CIVCOM, which is a new image processing method based on a vector-based scheme proposed in this study rather than raster-based schemes proposed by other researchers. This study shows usefulness of CIVCOM through comparison of rainfall data produced by image processing methods including traditional raster-based schemes and a newly proposed vector-based one.

Measurement of Flexural Modulus of Lamination Layers on Flexible Substrates (유연 기판 위 적층 필름의 굽힘 탄성계수 측정)

  • Lee, Tae-Ik;Kim, Cheolgyu;Kim, Min Sung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.63-67
    • /
    • 2016
  • In this paper, we present an indirect method of elastic modulus measurement for various lamination layers formed on polymer-based compliant substrates. Although the elastic modulus of every component is crucial for mechanically reliable microelectronic devices, it is difficult to accurately measure the film properties because the lamination layers are hardly detached from the substrate. In order to resolve the problem, 3-point bending test is conducted with a film-substrate specimen and area transformation rule is applied to the cross-sectional area of the film region. With known substrate modulus, a modulus ratio between the film and the substrate is calculated using bending stiffness of the multilayered specimen obtained from the 3-point bending test. This method is verified using electroplated copper specimens with two types of film-substrate structure; double-sided film and single sided film. Also, common dielectric layers, prepreg (PPG) and dry film solder resist (DF SR), are measured with the double-sided specimen type. The results of copper (110.3 GPa), PPG (22.3 GPa), DF SR (5.0 GPa) were measured with high precision.

The Impact of Participative Leadership on Job Commitment of Employees: The Mediating Effect of Psychological Empowerment and The Moderating Effect of Issue Leadership (참여적 리더십이 구성원의 직무몰입에 미치는 영향: 심리적 임파워먼트의 매개효과와 이슈리더십의 조절효과)

  • Park, Bong-Je;Shin, Je-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.533-551
    • /
    • 2021
  • The purpose of this study was to analyze the influence of participative leadership on the job commitment of employees and to investigate the mediating effect of psychological empowerment and the moderating effect of issue leadership. A survey was conducted on employees working in various industries and analyzed using PROCESS macro (Hayes, 2013). The reliability and validity of measurement tools were reviewed through a preliminary survey, and the timing of measurement of independent variable and dependent variable was separated to overcome the common method bias. The results of the study are as follows. First, it has been confirmed that participative leadership has a positive influence on employee's job commitment. Second, participative leadership strengthened the psychological empowerment of employees, and through it, the indirect effect of improving the employee's job commitment was confirmed. Third, the moderating effect of issue leadership was confirmed in the relationship between participative leadership and psychological empowerment. Fourth, the moderated mediating effect was confirmed that the effect of participative leadership on job commitment through psychological empowerment is reinforced by issue leadership. This study contributes to the expansion of existing leadership research by empirically identifying the mechanism between participative leadership and employee's job commitment. Implications regarding the results of the study, limitations of the study, and future study tasks were discussed.

Assessment and Calibration of Ultrasonic Velocity Measurement for Estimating the Weathering Index of Stone Cultural Heritage (석조문화재의 풍화지수 산정을 위한 초음파속도의 평가 및 보정)

  • Lee, Young-Jun;Keehm, Young-Seuk;Lee, Min-Hui;Han, June-Hee;Kim, Min-Su
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.126-138
    • /
    • 2012
  • Ultrasonic method is widely used for the evaluation of weathering index and of degree of deterioration because it is easily applicable $in$ $situ$. The basic idea of the method is that the ultrasonic velocity decreases as a rock is being weathered. Thus, the difference of ultrasonic velocities between fresh rock and weathered rock indicates the degree of weathering. In this method, the ultrasonic velocity of fresh rock is assumed to be 5,000 m/s. However, this assumption can cause significant errors in estimating weathering index, especially in case that those rocks of the same type have a wide range of ultrasonic velocities such as in Korea. Therefore, we obtained twenty rock specimens and sixty core samples commonly used for stone cultural heritages in Korea, and measured ultrasonic velocities. From the results, we found that the ultrasonic velocities of the same rock type, granite samples range from 3,118 to 5,380 m/s, and that the estimated weathering index can be highly biased if we use the fixed value of 5,000 m/s. We created a database (DB) by combining the measurement data and reported it. We also measured ultrasonic velocities by direct and indirect methods to quantify the calibration coefficient for each sampling site. We found that the calibration coefficients vary widely from site to site (1.31-1.76). Other factors, such as operator bias and temperature did not show any significant effect on errors in ultrasonic velocity measurements. Lastly, we applied our ultrasonic velocity DB and calibration coefficients to a stone cultural heritage, Bonghwang-ri Buddha statue. Our estimation of the weathering index was 0.3, 0.1 smaller than that by conventional method. The degree of deterioration was also different, "moderately weathered", while conventional method gave "highly weathered". Since other independent studies reported that the degree of deterioration of the Buddha statue was "moderately weathered", our estimation seems to be more accurate. Thus our method can help accurately evaluate the weathering index and the conservation planning for a stone cultural heritage.

Studies on Determinant Factors of SCM Performance: From the Supplier Perspective (SCM 성과 결정요인에 관한 통합적 연구: 공급업체 관점으로)

  • Park, Kwang-Oh;Chang, Hwal-Sik
    • Asia pacific journal of information systems
    • /
    • v.21 no.1
    • /
    • pp.1-27
    • /
    • 2011
  • In an attempt to cope with widespread, dynamic, and accelerating changes in both internal and external business environments, companies often utilize information technologies such as SCM(Supply Chain Management). To date, SCM research has mainly focused on the effects of dynamic factors on SCM success and emphasized adoption strategies and critical success factors. Consequently, the effects of more static factors such as interdependency between SCM partners have been largely ignored. The purpose of this study, therefore, is to examine the effects of both dynamic and static factors on SCM performance by controlling for information quality and partnership quality. The five factors examined in this study include innovative ness, mutual dependency, quality of information, partnership quality, and SCM performance. All factors were examined from the perspective of part suppliers, except the mutual dependency which was examined from two aspects: supplier's dependency on customer and customer's dependency on supplier. Data was collected through five hundred survey questionnaires distributed to the part supplier companies that have implemented SCM systems for at least one year. As a result, a total of 170 valid responses were obtained. A structural equation research model was fitted using SAS 9.1.3 and SMART-PLS 2.0. The results of this study can be summarized as follows. First, innovativeness positively affected SCM information quality. SCM partnership quality, and ultimately SCM performance. The path coefficient between innovativeness and information quality was 0.387, with a t-value of 3.528. Innovativeness also had a positively direct effect on partnership quality. The path coefficient was 0.351 with a t-value of 3.366. The total effect of innovativeness on partnership quality was significant, although its indirect effect on partnership quality by altering information quality was negligible. The total indirect effect of innovativeness on SCM performance by affecting information quality and partnership quality was significant with a p-value of 0.014. Innovativeness played an important role in determining SCM performance. Second, mutual dependency showed no significant effect on SCM information quality. This result contradicts the earlier assertion that the more dependent two companies are, the more accurate and timely the information they exchange ought to be. This study showed that this may not be the case; a partner may provide information of poor quality even when it is strongly dependent on the other. Mutual dependency showed significant effect on partnership quality. However, when the mutual dependency perceived by suppliers was divided into two parts, one being a supplier's dependency on its customer company and the other being a customer's dependency on the supplier, the latter showed a significant impact on the perceived SCM partnership quality. This result indicates that a customer company can hardly improve the partnership quality perceived by suppliers by making them more dependent. It improves only when the suppliers perceive that their partners, typically having more bargaining power, are more dependent on them. The overall effect of mutual dependency of any kind on SCM performance, however, was not significant. Although mutual dependency has been mentioned as an important static factor influencing almost every aspect of cooperation on a supply chain, its influences may not be as significant as it was initially perceived to be. Third, the correlation between information quality and partnership quality was 0.448 with a p-value of less than 0.001. Information quality had a path coefficient of 0.256 to partnership quality with a t-value of 2.940. The quality of information exchanged between partners may have an impact on their partnership quality. Fourth, information quality also had a significant impact on SCM performance with a path coefficient of 0.325 with a t-value of 3.611. In this study, SCM performance was divided into four categories: product quality, cost saving, service quality, and order fulfillment. Information quality has Significant impacts on product quality, cost saving and service quality, but not on order fulfillment. Fifth, partnership quality, as expected, had a significant impact on SCM performance. The path coefficient was 0.403 with a t-value of 3.539. Partnership quality, like information quality, had positive impacts on product quality, cost saving and service quality, but showed no impact on order fulfillment. It seemed that order fulfillment is the hardest category of performance that SCM can satisfy. One major limitation of this study is that it surveyed only the suppliers. To better understand the dual aspects of SCM, it is important to survey both suppliers and the assemblers, especially in pairs. This research, to our best knowledge, was the first attempt to study the level of dependency between the two groups by measuring the dual aspects of SCM and studying mutual dependency from the categories of suppliers and assemblers each.. In the future, a more comprehensive and precise measurement of SCM characteristics needs to be achieved by examining from both the supplier's and assembler's perspectives.

Homologous and Heterologous Antibody Response of the Patients with Aspergillosis Against Young Mycelia of Aspergilli by Fluorescence Antibody Reaction (형광항체반응을 이용한 Aspergillus 증 환자의 균사표면항원에 대한 항체반응 양상에 관한 연구)

  • Moon, Hi-Joo;Kwon, Hyuk-Han
    • The Korean Journal of Mycology
    • /
    • v.17 no.2
    • /
    • pp.82-90
    • /
    • 1989
  • Detection of antibody against pathogenic fungi in serum specimens of the patients with pulmonary tuberculosis or other lung diseases has been carried out(male) using the indirect fluorescence antibody technique and immunodiffusion tests. Immunodiffusion tests revealed that 104(36.5%) out of 285 patients examined showed a positive precipitin reaction against one or more of fungal antigens. The majority of ID positive patients 64(61.5%) reacted with Aspergillus fumigatus antigen and 49(47.1%) patients reacted with Candida albicans antigen ID positive reaction to A. fumigatus was found little more frequently among male patients, while Candida albicans reactors were found more frequently among female patients. Age distribution of ID positive reactors was high(49.1-43.3%) in age group of 40-59 years, but least or none in age group of less than 30 years. Age of fungal mycelium used as antigen did not effect sensitivity of the indirect flubrescence (IF) technique in detecting antibody to A. fumigatus. Antibody class against A. fumigatus that showed highest titer was IgG and thus FITC labeled anti-IgG immunoglobulin shoul be preferable. As relatively large amount of cell wall components of Aspergilli shared antigenically, a considerable cross-reaction was observed among A. fumigatus, A. flavus and A. niger, but not much with C. albicans. While (IF) has much better sensitivity when compared with ID, relative specificity of the latter procedure cannot to be overried, so that they could be batter used together in order to obtain quantitative measurement of antibody with relative specificity.

  • PDF