• Title/Summary/Keyword: Indirect composite

Search Result 115, Processing Time 0.025 seconds

The Study on Material Expression of Interior Design to image the Sense of Being Alive (유기체 생명감각을 연상시키는 실내공간 재료 표현에 관한 연구)

  • 김정신;임오연
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.100-107
    • /
    • 2003
  • The space can recognize by experience of sense, the each space to make identity through this. The contemporary architecture make possible an experience of sense through a complex paradigm and a composite concept expression. The material is not the assist to make a form, but to induce an image and an emotion of designers. The new material make possible the different design expression and the new aesthetic value. The appearance of difference material means the possibility to realize a designer's concept. The purpose of the study Is to analyze the new possibility of material expression through the study on material expression of interior design to associate the sense of being alive, to use basic data of the relation the material and the creativity. The study range is to define the sense of being alive, to image expression of material. It is to analyze the expression method of materials through to analyze the contemporary interior design. The expression method of materials to image the sense of being alive is direct and indirect and compromise. The interior design is visually to realize designer's concept, and the interior designer has to realize their it. The later study is on detail of material, in order to realize of material.

Residual stress of cold-formed thick-walled steel rectangular hollow sections

  • Zhang, Xingzhao;Liu, Su;Zhao, Mingshan;Chiew, Sing-Ping
    • Steel and Composite Structures
    • /
    • v.22 no.4
    • /
    • pp.837-853
    • /
    • 2016
  • This paper presents the experimental and numerical study on the distribution of transverse and longitudinal residual stresses in cold-formed thick-walled structural steel rectangular hollow sections manufactured by indirect technique. Hole-drilling method is employed to measure the magnitude of the transverse and longitudinal surface residual stress distribution, and the effects of the residual stresses are evaluated qualitatively by sectioning method. It is shown that compared to normal cold-formed thin-walled structural hollow sections (SHS), the cold-formed thick-walled SHS has similar level of residual stress in the flat area but higher residual stresses in the corner and welding areas. Both the transverse and longitudinal residual stresses tend to open the section. In order to predict the surface residual stresses in the corners of the cold-formed thick-walled SHS, an analytical model is developed. 2D finite element simulation of the cold bending process is conducted to validate the analytical approach. It is shown that in analyzing bending for thick-walled sections, shifting of neutral axis must be considered, since it would lead to nonlinear and non-symmetrical distribution of stresses through the thickness. This phenomenon leads to the fact that cold-formed thick-walled SHSs has different distribution and magnitude of the residual stresses from the cold-formed thin-walled SHSs.

CEREC 3D System을 이용한 당일수복 (one-day treatment) 임상증례

  • Jeong, Hyo-Gyeong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2008
  • Application of CAD/CAM is changing the way partial or full veneer all ceramic restoration is made. CAD/CAM systems, which were used mainly in other industries, have been developed and introduced for the dental purposes recently. It produced a flood of information on the CAD/CAM systems. It also influenced the development of restorative materials and all ceramic is substituting the traditional restorative materials of gold, composite resin and metal. Price increase of gold and other raw materials made the all ceramic more appealing. The introduction of a CEREC 3D system was innovative in several ways. Image of the prepared tooth is captured by camera and impression taking is unnecessary. Restoration can be delivered to the patient on one appointment and it will satisfy the demand of busy patients. One-day treatment with direct CAD/CAM system saves time compared to indirect CAD/CAM system. More superior restoration can be produced if lab work such as the adaptability check and shade selection is cooperated with lab technician. Short working time and comparably superior shade compatibility of color block was close to ideal. In the future, restorations with better quality can be fabricated in less time to busy patients thanks to the development of CAD/CAM system and dental materials.

  • PDF

Design guides to resist progressive collapse for steel structures

  • Mirtaheri, M.;Zoghi, M. Abbasi
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.357-378
    • /
    • 2016
  • The progressive collapse phenomenon in structures has been interested by civil engineers and the building standards organizations. This is particularly true for the tall and special buildings ever since local collapse of the Ronan Point tower in UK in 1968. When initial or secondary defects of main load carrying elements, overloads or unpredicted loads occur in the structure, a local collapse may be arise that could be distributed through entire structure and cause global collapse. One is not able to prevent the reason of failure as well as the prevention of propagation of the collapse. Also, one is not able to predict the start point of collapse. Therefore we should generalize design guides to whole or the part of structure based on the risk analysis and use of load carrying elements removal scenario. There are some new guides and criteria for elements and connections to be designed to resist progressive collapse. In this paper, codes and recommendations by various researchers are presented, classified and compared for steel structures. Two current design methods are described in this paper and some retrofitting methods are summarized. Finally a steel building with special moment resistant frame is analyzed as a case study based on two standards guidelines. This includes consideration of codes recommendations. It is shown that progressive collapse potential of the building depends on the removal scenario selection and type of analysis. Different results are obtained based on two guidelines.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

COLOR DIFFERENCES BETWEEN RESIN COMPOSITES BEFORE- AND AFTER-POLYMERIZATION, AND SHADE GUIDES (복합레진의 광중합 전·후와 shade guide의 색차 비교)

  • Chon, Yi-Ju;Cho, Sung-Shik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.299-309
    • /
    • 1999
  • The composite resin, due to its esthetic qualities, is considered the material of choice for restoration of anterior teeth. With respect to shade control, the direct-placement resin composites offer some distinct advantages over indirect restorative procedures. Visible-light-cured (VLC) composites allow dentists to match existing tooth shades or to create new shades and to evaluate them immediately at the time of restoration placement. Optimal intraoral color control can be achieved if optical changes occurring during application are minimized. An ideal VLC composite, then, would be one which is optically stable throughout the polymerization process. The shade guides of the resin composites are generally made of plastic, rather than the actual composite material, and do not accurately depict the true shade, translucency, or opacity of the resin composite after polymerization. So the numerous problems associated with these shade guides lead to varied and sometimes unpredictable results. The aim of this study was to assess the color changes of current resin composite restorative materials which occur as a result of the polymerization process and to compare the color differences between the shade guides provided with the products and the actual resin composites before- and after-polymerization. The results obtained from this investigation should provide the clinician with information which may aid in improved color match of esthetic restoration. Five light activated, resin-based materials (${\AE}$litefil, Amelogen Universal, Spectrum TPH VeridonFil-Photo, and Z100) and shade guides were used in this study. Three specimens of each material and shade combination were made. Each material was condensed inside a 1.5mm thick metal mold with 10mm diameter and pressed between glass plates. Each material was measured immediately before polymerization, and polymerized with Curing Light XL 3000 (3M Dental products, USA) visible light-activation unit for 60 seconds at each side. The specimens were then polished sequentially on wet sandpaper. Shade guides were ground with polishing stones and rubber points (Shofu) to a thickness of approximately 1.5mm. Color characteristics were performed with a spectrophotometer (CM-3500d, Minolta Co., LTD). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$ and $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E{^*}ab$) of resin composites before the polymerization process and shade guides using the post-polishing color of the composite as a control, CIE standard D65 was used as the light source. The results were as follows. 1. Each of the resin composites evaluated showed significant color changes during light-curing process. All the resin composites evaluated except all the tested shades of 2100 showed unacceptable level of color changes (${\Delta}E{^*}ab$ greater than 3.3) between pre-polymerization and post-polishing state. 2. Color differences between most of the resin composites tested and their corresponding shade guides were acceptable but those between C2 shade of ${\AE}$litefil and IE shade of Amelogen Universal and their respective shade guides exceeded what is acceptable. 3. Comparison of the mean ${\Delta}E{^*}ab$ values of materials revealed that Z100 showed the least overall color change between pre-polymerization and post-polishing state followed by ${\AE}$litefil, VeridonFil-Photo, Spectrum TPH, and Amelogen Universal in the order of increasing change and Amelogen Universal. Spectrum TPH, 2100, VeridonFil-Photo and ${\AE}$litefil for the color differences between actual resin and shade guide. 4. In the clinical environment, the shade guide is the better choice than the shade of the actual resin before polymerization when matching colors. But, it is recommended that custom shade guides be made from resin material itself for better color matching.

  • PDF

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

Comparative Diagnostic Studies on Serologic and Molecular Biological Tests Against Haemorrhagic Fever with Renal Syndrome (신증후출혈열 환자의 혈청학적 및 분자생물학적 진단 검사법 비교)

  • 우영대;문희주;배형준
    • Biomedical Science Letters
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2000
  • The etiologic agents of haemorrhagic fever with renal syndrome (HFRS) in Korea are Hantaan and Seoul virus in the genus Hantavirus, family Bunyaviridae. Antibody titers of sera from HFRS patients against Hantaan virus were measured by immunofluorescent antibody technique (IFAT), enzyme-linked immunosorbent assay (ELISA), high density composite particle agglutination (HDPA) and plaque reduction neutralization test (PRNI). PRNT and nested reverse transcriptase polymerase chain reaction (nested RT-PCR) was used for serotypic differentiation of Hantaviruses against Hantaan and Seoul virus. Eight doubtful HFRS patients showed higher fluorescent, IgG ELISA, agglutination and neutralizing antibody titer by IFAT, ELISA IgG, HDPA and PRNT, respectively Five out of them showed high IgM antibody titer by IgM capture ELISA against Hantaan virus, remarkably. Fifteen HFRS patients showed higher fluorescent antibody titer by IFAT. In PRNT, 12 out of them showed high neutralizing antibody titer against HTNV, 2 against SEOV and 1 against both viruses. In nested RT-PCR using serotype specific-primer, 3 out of them showed positive against HTNV and 1 against SEOV.

  • PDF

Visitor Adjustment and Coping Behavior for Use Level in a Recreational Setting - A Case Study of Bukhansan National park - (휴양환경 이용수준에 대한 방문객의 적응 및 대응행동 - 북한산 국립공원 소귀천 탐방로를 대상으로 -)

  • 허학영;안동만
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.6
    • /
    • pp.38-46
    • /
    • 2003
  • Perceived crowding is known as a necessary method to evaluate social carrying capacity in recreational settings. But according to the results of previous research, perceived crowding, use density, and satisfaction have shown weak and indirect correlations. The theory of visitors’ adjustment is one of several possible explanations for this poor relation. But the validity of the visitors’ adjustment theory has not been not inspected clearly. Therefore, the purposes of this study are to understand visitors’ adjustment theory and to examine visitors’ adjustment to the overuse of recreational settings. Study hypotheses were formulated through literature review and related to visitors’ adjustment in recreation density. Pour hypotheses were established and inspected with the case study, i.e., Rationalization : Visitors’ satisfaction isn't related to use density in recreation setting, 2) Product-shift : Preference norm is related to current use density, 3) Self-selection : Visitors’ satisfaction for the use level is generally high, and 4) Displacement : Norm interference is related to willingness to revisit. The case study was conducted during May and June,2001. According to the results of this survey, visitors adjust to overuse of recreation setting through rationalization and product shift (hypotheses l/2 acceptance). Current use density isn't related to visitors’ satisfaction and willingness to revisit (see table 3). And visitors’ preference norm is modified by situation (see table 4). Visitors’ satisfaction and willingness to revisit don't show a high correlation but moderately high (see table 5, hypothesis 3 acceptance). Differences between visitors’ preference norm and current use density is norm interference. Norm interference isn't related to willingness to revisit (see table 7). Therefore, the norm interference concept is not a useful method to explain visitors’ adjustment to the degree of overuse in a recreational setting (hypothesis 4 rejection). As for future directions, the following are proposed: 1) correctly understanding and reestablishing the visitor norm and norm interference concept, 2) introducing a composite research method to monitor visitors’ behavior and survey visitors’ attitudes and coping responses. These efforts would be helpful in the Planning and management of recreational settings to improve the quality of visitors’ experiences.

THE COLOR STABILITY OF AESTHETIC RESTORATIVE MATERIALS RESULTING FROM ACCELERATED AGING

  • Lee, Jeong-Seon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.577-585
    • /
    • 2008
  • STATEMENT OF PROBLEM: The discoloration of anterior teeth restoration is one of the material problems demanding retreatment. OBJECTIVES: To evaluate the color stability and affecting factors on esthetic restorative materials when subjected to accelerated aging. MATERIAL AND METHODS: This study was conducted using porcelain disks (IPS Empress 2-glazed, IPS Empress 2-polished), direct restorative resin disks (SYNERGY Duo) and indirect restorative resin disks (Sinfony, TESCERA ATL). Accelerated aging was done by precipitating the specimens in 38.C distilled water and irradiating with xenon light, and the total irradiation was 397.98 KJ/mm. Color and microhardness change of the specimens were measured before accelerated aging and after 100 hours, 200 hours and 300 hours of accelerated aging, and Surface of the specimens were examined with SEM before and after 300 hours of accelerated aging. RESULTS: 1. After 300 hours' accelerated aging, a ${\Delta}E$ value was 3.3 or lower in IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony. 2. After 300 hours' accelerated aging, gloss was lost and surface changes including microcracks were observed in TESCERA ATL and SYNERGY Duo, and color changes of them ranged between 3.58 and 6.40 ${\Delta}E$ units. 3. During 300 hours' accelerated aging, the microhardness of surface was increased by 3.21 - 19.64% in all kinds of composites resin. CONCLUSION: After 300 hours' accelerated aging, SEM images IPS Empress 2-glazed, IPS Empress 2-polished and Sinfony showed little morphological change and their color changes were considered to be clinically acceptable. And there was significant correlation between microhardness changes and color changes of composites (P < .05).