• Title/Summary/Keyword: Indirect PIN

Search Result 16, Processing Time 0.018 seconds

A Development of Analytical Strategies for Elastic Bifurcation Buckling of the Spatial Structures (공간구조물의 탄성 분기좌굴해석을 위한 수치해석 이론 개발)

  • Lee, Kyung Soo;Han, Sang Eul
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.563-574
    • /
    • 2009
  • This paper briefly describes the fundamental strategies--path-tracing, pin-pointing, and path-switching--in the computational elastic bifurcation theory of geometrically non-linear single-load-parameter conservative elastic spatial structures. The stability points in the non-linear elasticity may be classified into limit points and bifurcation points. For the limit points, the path tracing scheme that successively computes the regular equilibrium points on the equilibrium path, and the pinpointing scheme that precisely locates the singular equilibrium points were sufficient for the computational stability analysis. For the bifurcation points, however, a specific procedure for path-switching was also necessary to detect the branching paths to be traced in the post-buckling region. After the introduction, a general theory of elastic stability based on the energy concept was given. Then path tracing, an indirect method of detecting multiple bifurcation points, and path switching strategies were described. Next, some numerical examples of bifurcation analysis were carried out for a trussed stardome, and a pin-supported plane circular arch was described. Finally, concluding remarks were given.

Considering the Multi-Purpose Display Designed for Aircraft Lightning Protection (낙뢰보호를 고려한 항공기용 다목적 디스플레이 설계)

  • Cheon, Young-Ho;Lee, Seoung-Pil;Park, Jun-Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.445-454
    • /
    • 2014
  • In this paper, we introduce measures designed content for RTCA DO-160 F, Section 22 tests performed to verify the effects of indirect lightning and testing process of the test was carried out in the multi-purpose display certification process. This is referred to as indirect effects of lightning capability of an aircraft having electrical electronic equipment failure or damage to bring lightning induced voltages. In order to protect the avionics from lightning indirect effects of these aircraft are analyzing the effects of lightning strikes on aircraft and aircraft systems and interior design needs protection against the threat on their part. In this paper, we introduce RTCA DO-160 F, component selection process according to Section 22 category selection method and the selected level for determining the level of such measures for protection against lightning of multipurpose display for this aircraft. It also introduces the actual test process to confirm that the designed effectiveness of the selected part. We expect a good example of the lightning planned for future development of measures designed avionics through each step of the process introduced this.

Usefulness of indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture associated with orbital blowout fracture

  • Kim, Tae Ho;Kang, Seok Joo;Jeon, Seong Pin;Yun, Ji Young;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2018
  • Background: Nasal fracture and orbital blowout fracture often occur concurrently in cases of midface blunt trauma. Generally, these multiple fractures treatment is surgery, and typically, the nasal bone and orbit are operated on separately. However, we have found that utilizing a transconjunctival approach in patients with concurrent nasal bone fracture and orbital blowout fracture is a useful method. Methods: The participants in the present study included 33 patients who visited the Plastic Surgery outpatient department between March 2014 and March 2017 and underwent surgery for nasal fracture and orbital blowout fracture. We assessed patients' and doctors' satisfaction with surgical outcomes after indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture with associated orbital blowout fracture. Results: According to the satisfaction scores, both patients and doctors were satisfied with transconjunctival approach. Conclusion: We presented here that our method enables simultaneous operation of nasal fracture accompanied by orbital blowout fracture, rather than treating the two fractures separately, and it allows precise reduction of the nasal fracture by direct visualization of the fracture site without any additional incisions or difficult surgical techniques. Also, by preventing the use of excessive force during reduction, this method can minimize damage to the nasal mucosa, thereby reducing the incidence of nasal bleeding.

A Study on the Indirect Copy of Dancheong Patterns Using Three-dimensional Scanning (3차원 스캐닝을 활용한 단청문양의 간접전사 연구)

  • An, Ji Eun;Choi, Chan Ho;Kim, Sung June;Yoon, Man Young
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.471-479
    • /
    • 2018
  • Seonunsa Temple is a site of Dancheong cultural significance in Daewoongjeon. Three-dimensional (3D) scanning can be used to create a simulation in 1:1 ratio without touching the Dancheong patterns directly. The traditional method of recreating Dancheong was paining with tracing paper using a fix pin. However, manual direct copy processes can cause and damage to the objects. This study shows the results of a simulation of a tranditional Dancheong patterns as an alternative; the simulation was able to reduce dimensional errors and prevent damage by using 3D scanning. As a result, objective and precise proportions of the simulation were acquired. The 3D scanning method may be applied for work such as the replication and restoration of the drawing, 3D fabrication of the original data, and printing of the additional drawing. In addition, with the production of 3D materials, a virtual museum is possible.

Dynamic Buckling Characteristics of Arch Structures by Running Response Spectrum (연속 응답 스펙트럼 분석에 의한 아치 구조물의 동적 좌굴 특성)

  • Kim, Seung-Deog;Yun, Tae-Young
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.2 s.12
    • /
    • pp.81-88
    • /
    • 2004
  • The dynamic instability of snapping phenomena has been studied by many researchers. Few papers deal with dynamic buckling under loads with periodic characteristics, and the behavior under periodic excitations is expected to be different from behavior under STEP excitations. We investigate the fundamental mechanisms of the dynamic instability when the sinusoidally shaped arch structures are subjected to sinusoidally distributed excitations with pin-ends. The mechanisms of dynamic indirect snapping of shallow arches are especially investigated under not only STEP function excitations but also under sinusoidal harmonic excitations, applied i the up-and-down direction. The dynamic nonlinear responses are obtained by the numerical integration of the geometrically nonlinear equation of motion. And using this analyze characteristics of the dynamic instability through the running response spectrum by FFT(Fast Fourier Transform).

  • PDF

An analysis on the Causes of the Under-Potential in the Electric Anti-corrosion Section (전기방식(電氣防蝕) 적용구간의 전위 미달 원인 분석)

  • Lee, Eun-Chun;Ryu, Keong-Man;Yoon, Han-Bong;Shin, Gang-Wook;Hong, Sung-Taek;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.55-57
    • /
    • 2005
  • Along with the development of the industrial society, as the transportation of water which is the indirect capital of society and petroleum, gas, etc used as energy sources is rapidly increased. the underground material is being expanded. Like this, the pipes laid under the ground not only bring the corrosion to the land circumstances to reduce the life of the pipes, but also raise the social problem of leakage accidents and the economic loss by Pin Hole. By reason of this, for the purpose of protecting the corrosion of the underground material, we are constructing and operating the electrolytic protection facilities. In case of a region of which specific resistance is high, however, we are not keeping proper protection potential(that is -850mV) to get protection effects. In this study, for the water pipes that under-voltage phenomena occur in the protection potential, we made a spot survey on the under-voltage section and normal-voltage section, compared, analyzed each of the contents and examined the under-voltage causes of the protection potential.

  • PDF