• Title/Summary/Keyword: Indirect Measurement

Search Result 442, Processing Time 0.031 seconds

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement (간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

A Study on the Evaluation of the Automatic Measurement Method of Plastic Strain Ratio by Two Extensometers (신장계에 의한 소성변형비 자동측정법의 평가에 관한 연구)

  • 김인수
    • Transactions of Materials Processing
    • /
    • v.12 no.5
    • /
    • pp.504-512
    • /
    • 2003
  • The plastic strain ratios(R-values) of low carbon steel sheets were determined by the automatic strain measurement method using two extensometers, the indirect photo method for the same tensile specimen during tensile test and the indirect method for the specimen after tensile test. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method using two extensometers coincided with those from the indirect photo method and the indirect method for all tensile specimens. In addition, the strain dependence of plastic strain ratios could be continuously recorded and the anisotropy of the strength coefficient, K, and strain hardening exponent, n, could be automatically calculated in three directions by computer through the use of two extensometers. The experimental results showed that the strain dependence of R-value was related to the anisotropy of strain hardening exponent in low carbon steel sheets.

Evaluation of Indirect Methods of Engine Torque Measurement (엔진 토크의 간접적(間接的)인 측정(測定) 방법(方法)에 관한 연구(硏究))

  • Ryu, K.H.;Kang, S.B.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 1991
  • This study was carried out to evaluate indirect methods of engine torque measurement. Three indirect methods based on throttle valve opening, exhaust gas temperature and inlet air pressure were compared. The indirect method based on throttle valve opening appeared to be the most satisfactory in terms of accuracy and response time. The discrepancies between the direct method and the indirect method based on throttle valve opening in measuring engine torque were 2% on t he average.

  • PDF

Representative Male Upper Body types of the 20s by the Combination of Direct and Indirect Measurement Values (직접측정치(直接測定値)와 간접측정치(間接測定値)의 결합(調合)에 의한 20대(代) 남성(男性) 상방신(上半身) 대표체형(代表體型) 연구( 硏究))

  • Li, Eun-Ji;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.4
    • /
    • pp.135-151
    • /
    • 2007
  • This study is human body measurement of 200 adult males in their 20s by both direct and indirect methods in order to reveal the representative male upper body types. Composition factors of body types were classified while the combination of direct-indirect measurement values was chosen. The following are the findings: 1) The analysis of direct-indirect measurement statistics showed the following results: 173.80cm (height), 69.87kg (weight), 95.58cm (chest girth), $24.67^{\circ}$ (right shoulder angle), and $9.34^{\circ}$ (shoulder width angle). 2) The factor analysis of the body types by direct measurement produced 5 factors: 1 (front length of upper body), 2 (front length of upper body), 3 (back length of upper body), 4 (circumference of upper body), and 5 (shoulders length). These factors accounted for 90.08%. Also, the cluster analysis of factor scores led to 3 types: 1 (33%, short, comparatively wide shoulders and full in the hips), 2 (25.1%, well-developed upper body in tall, inversed triangle), 3 (41%, average height, short upper body). 3) The body-type factor analysis by indirect measurement resulted in 6 factors with the explanation of 83.24%: 1 (rear upper bady thickness), 2 (front upper body width), 3 (front chest thickness), 4 (left-right shoulder angle), 5 (front width of protrusion distance in chest and shoulders), and 6 (neck's front-rear side angle).In addition, the cluster analysis of factor scores brought about 4 types: 1 (15%, well-developed front chest, beardless waist), 2 (23.5%, flat chest, with shoulder, drooping shoulders, strait neck), 3 (39%, with shoulder, curved back), and 4 (22.5%, narrow and thin, curved waist). 4) Among the 118 subjects (75%), 58 subjects commonly appearing in indirect measurement values group and direct measurement values group were chosen the representative body type group according to asterisk indexes. They had the highest frequency in direct type 3 and indirect type 3, whose combination represented the physical characteristics of the representative body types.

Classification and Characteristic of Upper Body for the Construction of a College Women's Clothing (여대생의 의복설계를 위한 상반신 체형 분류 및 특성)

  • 심정희;함옥상
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.3
    • /
    • pp.321-332
    • /
    • 1998
  • The purpose of this study is to provide basic data for more functional and more fitting clothing construction. The subjects were college women aged from 18 to 25 in June, 1997. Data were collected by anthropometry and photometry and analyzed by the characteristic of the upper body- The results are as follows: 1. After analyzing direct anthropometric data, 1 have analyzed the data by the characteristic in each somatotype, classified them and I have had 5 groups. Group 1 with middle height and standard type, group 2 with great height and standard type, group 3 with low height and slim type, group 4 with middle height and fat type, and group 5 with low height and a little fat type. 2. After analyzing indirect photometric data, 1 have analyzed them by the characteristic and I have had 4 groups. Group 1 with lean back type, group 2 with sway back type, group 3 with straight type and group 4 with bend forward type. 3. Through the mutual corresponding relation in the 5 groups classified with direct anthropometric measurement and the 4 groups classified with indirect photometric mea- surement, direct-group 1 comes the most corresponding to indirect-group 2, comes second to indirect-group 4, and comes third to indirect-group 1. Direct-group 2 comes the most corresponding to indirect-group 4, direct-group 3 comes the most corresponding to indirect- group 1, direct-group 4 comes the most corresponding to indirect-group 3, and direct-group 5 comes the most corresponding to indirect-group 1.

  • PDF

Precise Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (Indirect force 측정 방법과 Pseudo-역행렬을 이용한 정밀한 Force 예측)

  • 심재술;안병하;하종훈;정현출
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.564-567
    • /
    • 1997
  • In the design of structure the forces acting on the structure are important parameter for noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. Thus it is necessary to find out indirect force evaluation method. In this paper forces have been measured with in-situ vibration responses and system information. Three existing techniques of indirect force measurement, viz. direct inverse, principal component analysis and regularization have been compared. It has been shown that multi-vibration responses are essential for the precise estimation of the forces. To satisfy those conditions, Rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It has also been obtained that relatively higher force is transmitted though three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate and is investigated the possibility of force evaluation of rotary compressor as a complex structure.

  • PDF

Frequency Response of the electrode for Indirect-contact ECG (간접접촉 심전도 측정용 전극의 주파수 특성)

  • Lim, Yong-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.