• 제목/요약/키워드: Indirect Energy

Search Result 464, Processing Time 0.027 seconds

A Study on the Induce Effects of Energy Consumption among Industries (산업별 에너지 소비의 유발효과에 관한 연구)

  • Cho, Sang-Sup;Kim, Dong-Yeub;Kang, Shin-Won
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.637-652
    • /
    • 2009
  • We measure and compare inducements of energy consumption in different industry sectors using inter-industry input and output tables of 1995, 2000 and 2005. We also compute the multiplier effects that relate to the directions of future economic effects. Key Findings are as follows. First, we observe continues decreasing linkage effects in all industries over period of 1995 to 2007. Second, backward multiplier of energy consumption were highest in the material related industry and chemical industry. As for inter-industry inducements, the indirect backward multipliers were high in the other industry. Third, the forward multiplier effect of energy consumption were as same as the backward multiplier effect's sectors. The indirect forward multipliers, however, were highest in the material related industry and chemical industry. The above findings show that since implementing pro-environmental policy in 2000s, the industries structure for reducing energy consumption has been transformed.

  • PDF

Performance Improvement of Precooling Process and Cold Box in Hydrogen Liquefaction Process Using LNG Cold Energy (LNG 냉열이용 액체수소 제조공정의 예냉 및 Cold box의 성능 개선 연구)

  • Yun, Sang-Kook;Yoon, Na-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.56-61
    • /
    • 2020
  • For the hydrogen liquefaction, the large amount of energy is consumed, due to precooling, liquefaction and o-p conversion processes. The aim of this work is to improve the performance of hydrogen liquefaction process by introducing the new energy saving processes, that are the liquid nitrogen precooling process by using LNG cold energy, and the new design of cold box insulation using cold air circulation. The results show that the indirect use of LNG cold energy in precooling process enables not only to get energy saving, but to make safer operation of liquefaction plant. In new cold box, the energy loss of equipments could be reduced by nearly 35%~50% compared to the present perlite insulation, if insulation structure is organised as 3mm steel wall/20cm PUF/5cm air/20cm PUF/equipment. Additionally the equipments installed in cold box can get cooling effect, if the temperature is higher than the temperature of cold air. The application of this results can gives to increase the liquid yield of about 50% substantially in industrial hydrogen liquefaction plant.

Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System (건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석)

  • IN, JUNGHYUN;LEE, YULHO;KANG, SANGGYU;PARK, SUNGJIN
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.2
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

Analysis of Heating and Desalination Cycle Using Low Temperature Seawater (저온 해수를 이용한 난방 및 담수화사이클 성능 해석)

  • Lee, H.S.;Lee, S.W.;Jung, D.H.;Moon, D.S.;Kim, H.J.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.301-306
    • /
    • 2011
  • The paper presents an analysis of the heating cycle and discusses a desalination cycle that uses lowtemperature seawater. The basic heating cycle model is the heat pump cycle, and seawater desalination is usually performed by the indirect freezing desalination method. The low temperature of the seawater (below $5^{\circ}C$) acts as the heat source of the evaporator. R-134a, R-1234yf, R-600a are used as working fluids. In the 2-stage compression cycle, the compressor's work decreased by about 15.6% from that in the 1-stage compression cycle. Further, the COP in the 2-stage cycle was 17.6% higher than that in the 1-stage cycle. In the indirect desalination cycle, the energy per unit fresh water productivity in the 2-stage cycle was 19.8% lower than that in the 1-stage cycle.

Economic Assessment of a Indirect Liquefaction Process using a Gasification with Petroleum Coke/Coal Mixtures (석유코크스/석탄 혼합 가스화를 이용하는 액화 공정의 경제성 평가)

  • Shin, Ji-Hoon;Lee, Lu-Se;Lee, See-Hoon
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.501-509
    • /
    • 2016
  • The economic feasibility of a commercial indirect liquefaction process with the co-gasification process of petroleum coke which has been recognized as hazardous waste because of high sulfur content and bituminous coal and sub-bituminous coal mixtures was assessed. The 2,000 ton/day scale indirect liquefaction process including co-gasification, clean up, Fischer-Tropsch conversion and so on was assumed and used to analyze economical efficiencies with various conditions. Financial data from previous studies were modified and used and economical sensitivities with various mixture ratios were evaluated in this study. As a result, economic values of petroleum coke were superior than those of coals because of increasing sulfur sale. Also, mixtures with petroleum coke and bituminous coal was more favorable that those with petroleum coke and sub-bituminous coal due to lower moisture content. In case of sub-bituminous coal, the mixture ratio with petroleum coke had to be over 40wt% for the IRR of mixture to surpass 10%.

Catalytic Gasification of Mandarin Waste Residue using Ni/CeO2-ZrO2

  • Kim, Seong-Soo;Kim, Jeong Wook;Park, Sung Hoon;Jung, Sang-Chul;Jeon, Jong-Ki;Ryu, Changkook;Park, Young-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3387-3390
    • /
    • 2013
  • Catalytic gasification of mandarin waste residue was carried out using direct and indirect catalyst-contact methods for the first time. In the indirect method, non-catalytic reaction in a reactor was followed by catalytic upgrading of vapor product in another reactor. Two different catalysts, $Ni/{\gamma}-Al_2O_3$ and $Ni/CeO_2-ZrO_2$, were employed. $CeO_2-ZrO_2$ support was prepared using hydrothermal synthesis in supercritical water. The catalysts were characterized by $H_2$-temperature programmed reduction and Brunauer-Emmett-Teller analyses. Under the condition of equivalent ratio (ER) = 0, the indirect catalyst-contact method led to a higher gas yield than the direct method. Under ER = 0.2, the yield of biogas obtained over $Ni/CeO_2-ZrO_2$ was higher than that obtained over $Ni/{\gamma}-Al_2O_3$. Also, the coke formation of $Ni/CeO_2-ZrO_2$ was lower than that of $Ni/{\gamma}-Al_2O_3$. Such results were attributed to the higher reducibility and better lattice oxygen mobility of $Ni/CeO_2-ZrO_2$, which were advantageous for partial oxidation reaction.

Comparison of Resting Energy Expenditure Using Indirect Calorimetry and Predictive Equations in Trauma Patients: A Pilot Study

  • Ma, Dae Sung;Lee, Gil Jae
    • Journal of Trauma and Injury
    • /
    • v.34 no.1
    • /
    • pp.13-20
    • /
    • 2021
  • Purpose: Nutritional therapy in the intensive care unit is an essential factor for patient progress. The purpose of this study was to compare resting energy expenditure (REE) calculated by prediction equations (PEs) to the REE measured by indirect calorimetry (IC) in trauma patients. Methods: Patients admitted to the trauma intensive care unit who received mechanical ventilation between January and December 2015 were enrolled. REE was measured by IC (CCM Express, MGC Diagnostics) and calculated by the following PEs: Harris-Benedict, Fleisch, Robertson and Reid, Ireton-Jones, and the maximum value (25 kcal/kg/day) of the European Society for Clinical Nutrition and Metabolism (ESPEN). All patients were ventilated at a fraction of inspired oxygen (FiO2) below 60%. Results: Of the 31 patients included in this study, 24 (77.4%) were men and seven (22.6%) were women. The mean age of the patients was 49.7±13.2 years, their mean weight was 68.1±9.6 kg, and their mean Injury Severity Score was 26.1±11.3. The mean respiratory quotient on IC was 0.93±0.19, and their mean FiO2 was 38.72%±6.97%. The mean REE measured by IC was 2,146±444.36 kcal/day, and the mean REE values calculated by the PEs were 1,509.39±205.34 kcal/day by the Harris and Benedict equation, 1,509.39±154.33 kcal/day by the Fleisch equation, and 1,443.39±159.61 kcal/day by the Robertson and Reid equation. The Ireton-Jones equation yielded a higher value (2,278.90±202.35 kcal/day), which was not significantly different from the value measured using IC (p=0.53). The ESPEN maximum value (1,704.03±449.36 kcal/day) was lower, but this difference was likewise not significant (p=0.127). Conclusions: The REE measured by IC was somewhat higher than that calculated using PEs. Further studies are needed to determine the proper nutritional support for trauma patients.

Development of High Efficiency Boiler with High Safety (안전성이 높은 고효율 보일러 개발에 관한 연구)

  • Jung, Won
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.83-95
    • /
    • 2011
  • Boiler efficiency has a direct impact on energy consumptions, which results in lower cost of operations and services. Usually high efficiency boilers are regarded as boilers with an efficiency of greater than 90%. However, it is likely that normal boilers are running at significantly lower efficiencies than this. This paper presents a process of developing a highly efficient energy consumption boiler. We adopt direct heat method while normal boilers are designed as indirect heat method. The submerged combustion method is considered to design for very high efficient boiler.

An Economical Analysis on Fuel Switching Model of Coal Power Plant using Herbaceous Biomass (초본계 바이오매스 활용 석탄발전소 연료전환 모형 경제성분석 연구)

  • Um, Byung Hwan;Kang, Chan Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.89-99
    • /
    • 2019
  • The project to utilize kenaf as thermal power plant fuel has a positive effect on the unused energy utilization, greenhouse gas reduction, and farm income. However, it is analyzed that it is difficult to secure economical efficiency because the fuel cost of kenaf is higher than that of power by thermal power plant and Renewable Energy Certification (REC). The project of power generation using kenaf is meet the government's major policies, while government support is essential for securing economical efficiency. As a result of the sensitivity analysis on the ratio of the government subsidies, to secure economical efficiency, the power generation prices using kenaf through the direct financial support of the government indicate that 47% and 76% of kenaf fuel cost are supported by government in case of the Saemangeum reclamation and Gangneung-si, respectively. In the case of the government indirect policy support, if kenaf is included as a renewable energy source of Renewable Energy Portfolio Standard and REC is granted, the economic efficiency of Saemangeum reclamation and Gangneung-si is obtained when REC secured at 1.05 or more and 2.43 or more, respectively. The results of this study are meaningful in that the direct and indirect effects of the government on the development of the herbaceous energy crop, kenaf, were evaluated economically. These results are to suggest the need for demonstration study, but economics analyze and evaluate are necessary based on operational data through the demonstration phase in the future.

Characteristics of Low Calorific Value of Sewage Sludge by Drying Method (수직원통식 박막 건조방식에 의한 하수슬러지의 저위발열량 특성)

  • Mo, Jounggun;Lee, Kwangsung;Chung, Hanshik
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.55-62
    • /
    • 2017
  • In this study, the water content and the low calorific value of the dried sludge are analyzed by using a vertical cylinder type indirect heating type dryer for evaluatation of energy source value. The vertical cylindrical thin film dryer was an Okadora Pilot Plant, and the dryer was indirect heating vertical thin film type. The internal standard consisted of 500 mm in diameter and 700 mm in height. In the drying experiment, 10 kg of dehydrated sewage sludge was added to the dryer and the total amount of the sludge was adjusted to 27 times by variable of the time, the number of revolutions and the steam temperature. The results of analysis of the 27th experiment component of the dried product showed that the average low calorific value of about 11.2 MJ/kg and the water content of 6%. This is satisfy the fuel use standard of the thermal power plant of the sludge.