• Title/Summary/Keyword: Indicate System

Search Result 4,424, Processing Time 0.031 seconds

Computer Simulation of an Absorption Heat Pump for Recovering Low Grade Waste Heat (저온 폐열 회수를 위한 제1종 흡수식 열펌프의 컴퓨터 시뮬레이션)

  • Karng, S.W.;Kang, B.H.;Jeong, S.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-197
    • /
    • 1996
  • A computer program for thermal design analysis has been developed to predict the operating characteristics and performance of an absorption heat pump to recover $30{\sim}40^{\circ}C$ of waste hot water. The effects of heat transfer area of the system components, temperature and mass flow rate of heat transfer medium, and solution circulation rate on the system performance are investigated in detail. The results obtained indicate that the COP is increased with a decrease in the temperature of driving steam and with an increase in the temperature of waste hot water while the COP is little affected by the variation of a hot water temperature. It is also found that the heating output is increased with an increase in the temperature of waste hot water and driving steam as well as with a decrease in the temperature of hot water. The simulation results are also compared with the experimental results for a periodic operation of the system and obtained a satisfactory agreement.

  • PDF

Performance Analysis of Combined Passive Solar System for Building South Wall (남측외벽에 적용한 혼합형 태양열시스템의 성능 분석)

  • Yun, Tae-Gyun;Lee, Hyun-Soo;Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

Analysis of the LED Lamp Arrangement for Uniformity of Illumination in Indoor VLC System

  • Hao, Hong-Gang;Zhang, Dan-Dan;Tang, Shuai
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.663-671
    • /
    • 2014
  • LED lamp arrangement is a critical issue in indoor visible light communication (VLC) system. In this paper, we analyze the illumination distribution under the arrangement of $2{\times}3$ and propose a method to find the optimal lamp arrangement. The method, based on the MIMO (Multiple Input/Multiple Output) system model and taking the first order reflection into consideration, enables accurate analysis of the arrangement of the LED lamps for any room. The studies show that under the optimal arrangement the uniformity of illumination is improved from 0.55 to 0.86, which guarantees that users can get almost equal lighting effects, no matter where they locate themselves. At the same time, the RMS delay spread distribution which is used to evaluate the inter-signal-interference (ISI) is analyzed, and the simulation results indicate that the optimal arrangement also can improve the communication quality by reducing the fluctuation of the RMS delay spread.

Synthesis and Properties of Hexyl End-Capped Thiophene Oligomers Containing Anthracene Moiety in the Center

  • Choi, Jung-Hei;Cho, Dae-Won;Jin, Sung-Ho;Yoon, Ung-Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.7
    • /
    • pp.1175-1182
    • /
    • 2007
  • A series of new organic semiconductors hexyl end-capped thiophene-anthracene oligomers containing the anthracene moiety in the center of the oligomers are synthesized. The target oligomers have been obtained by Stille coupling reactions as key step reactions. The synthesized thiophene-anthracene oligomers were characterized by 1H-NMR, 13C-NMR and high-resolution mass spectroscopy, respectively. All of the oligomers are soluble in chlorinated solvents. Their optical, thermal and electrochemical properties were measured. The hexyl end-capped oligomers and their unsubstituted oligomers exhibit the same absorption behavior in dilute toluene solution. Hexyl end-capped bis-terthienylanthracene oligomer is observed to show liquid crystalline mesophase at 166 oC in heating process. The thermal analyses as well as the electrochemical measurement data indicate that the designed materials show better thermal and oxidation stability than the corresponding oligothiophenes without anthracene core. Fluorescence lifetimes and fluorescence quantum yields of the thiophene-anthracene oligomers are measured to be 10-14 ps and 3.4-9.9 × 10?3 which are much shorter and lower than those of oligothiophenes respectively.

Choosing an optimal connecting place of a nuclear power plant to a power system using Monte Carlo and LHS methods

  • Kiomarsi, Farshid;Shojaei, Ali Asghar;Soltani, Sepehr
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1587-1596
    • /
    • 2020
  • The location selection for nuclear power plants (NPP) is a strategic decision, which has significant impact operation of the plant and sustainable development of the region. Further, the ranking of the alternative locations and selection of the most suitable and efficient locations for NPPs is an important multi-criteria decision-making problem. In this paper, the non-sequential Monte Carlo probabilistic method and the Latin hypercube sampling probabilistic method are used to evaluate and select the optimal locations for NPP. These locations are identified by the power plant's onsite loads and the average of the lowest number of relay protection after the NPP's trip, based on electricity considerations. The results obtained from the proposed method indicate that in selecting the optimal location for an NPP after a power plant trip with the purpose of internal onsite loads of the power plant and the average of the lowest number of relay protection power system, on the IEEE RTS 24-bus system network given. This paper provides an effective and systematic study of the decision-making process for evaluating and selecting optimal locations for an NPP.

Continuous Cultivation of Lactobacillus rhamnosus with Cell Recy-cling Using an Acoustic Cell Settler

  • Yang, Yun-Jeong;Hwang, Sung-Ho;Lee, Sang-Mok;Kim, Young-Jun;Koo, Yoon-Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.6
    • /
    • pp.357-361
    • /
    • 2002
  • Continuous production of lactic acid from glucose by Lactobacillus rhamnosus with cell recycling using an acoustic cell settler was carried out. The performance of the system, such as the concentration of cell and product were compared with the control experiment without recycling. The acoustic settler showed cell separation efficiency of 67% during the continuous operation and the cell concentration in the fermentor with recycle exceeded that of the control by 29%. Com-pared with the control, tactic acid production was increased by 40%, while glucose consumption was only increased by 8%. The higher value of lactic acid production to substrate consumption (Yp/s, product yield coefficient) achieved by cell recycling is interpreted to indicate that the recycled cell mass consumes less substrate to produce the same amount of product than the control Within system environmental changes due to the longer mean cell residence time induced the cells maintaining the metabolic pathways to produce Less by-Product but more product, lactic acid.

Fabrication of SiCOI Structures Using SDB and Etch-back Technology for MEMS Applications (SDB와 etch-back 기술에 의한 MEMS용 SiCOI 구조 제조)

  • Jung, Su-Yong;Woo, Hyung-Soon;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.830-833
    • /
    • 2003
  • This paper describes the fabrication and characteristics of 3C-SiCOI sotctures by SDB and etch-back technology for high-temperature MEMS applications. In this work, insulator layers were formed on a heteroepitaxial 3C-SiC film grown on a Si(001) wafer by thermal wet oxidation and PECVD process, successively. The pre-bonding of two polished PECVD oxide layers made the surface activation in HF and bonded under applied pressure. The wafer bonding characteristics were evaluated by the effect of HF concentration used in the surface treatment on the roughness of the oxide and pre-bonding strength. Hydrophilic character of the oxidized 3C-SiC film surface was investigated by ATR-FTIR. The strength of the bond was measured by tensile strengthmeter. The bonded interface was also analyzed by SEM. The properties of fabricated 3C-SiCOI structures using etch-back technology in TMAH solution were analyzed by XRD and SEM. These results indicate that the 3C-SiCOI structure will offers significant advantages in the high-temperature MEMS applications.

  • PDF

Comparison of Nursing Performance by Career Levels in a Nurse Career Ladder System (경력개발시스템 경력단계별 수술실 간호사 업무수행능력 비교)

  • Kim, Myoung-Sook;Park, Sung-Ae
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.2
    • /
    • pp.284-292
    • /
    • 2012
  • Purpose: This study was to compare nursing performance by career levels in a career ladder system. Methods: This survey was conducted with 140 OR staff nurses. Ten unit managers evaluated their own staff with a performance evaluation tool composed of 51 items. Data were analyzed by frequency, t-test, one-way ANOVA, ${\chi}^2$-test, and ANCOVA. Results: In career level CN II, nursing performance showed differences by personal characteristics. However, there was no significant difference in level CN III. CN IIIs' nursing performance was significantly higher than CN IIs' in all domains. Nursing performance of CN III was significantly higher than CN IIs' in 5 to 10 years of clinical experience. Although there was no significant difference in other clinical experience groups, CN IIIs' scores were always higher than CN IIs' Conclusion: The results indicate that nursing performance improves with career ladder advancement. Organizations should encourage advancement to higher levels and eliminate obstacles.

Comparison of the Functional Ambulation Performance Scores of Senior Adults With or Without a History of Falls (낙상 경험 유무에 따른 노인의 기능적 보행성취도 점수(FAP score) 비교)

  • Kwon, Hyuk-Cheol;Kong, Jin-Yong
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of the study was to determine if there was a difference in the Functional Ambulation Performance score of senior adults with or without a history of falls during walking at a preferred velocity. Twelve subjects with a history of falling (mean age=73.8) and eight subjects with no history of falling (mean age=70.4) participated in the study. Temporal and spatial parameters of gait were analyzed using the computerized GAITRite system. The GAITRite system integrates specific components of locomotion to provide a single, numerical representation of gait, the Functional Ambulation Performance score. The Functional Ambulation Performance score is a Quantitative means of assessing gait based on specific temporal and spatial parameters. Statistical analysis of the two groups demonstrated a significant decrease in Functional Ambulation Performance score for those with a history of falls. They had lower values for step/extremity ratios, mean normalized velocity, and greater values for step times, percent in double support. These results indicate that the GAITRite system can be useful in detecting footfall patterns and selected time and distance measurements of persons with a history of falls and the Functional Ambulation Performance score can be used as indicators of gait performance for senior adults with a history of falls.

  • PDF

Analytical solution of the Cattaneo - Vernotte equation (non-Fourier heat conduction)

  • Choi, Jae Hyuk;Yoon, Seok-Hun;Park, Seung Gyu;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.389-396
    • /
    • 2016
  • The theory of Fourier heat conduction predicts accurately the temperature profiles of a system in a non-equilibrium steady state. However, in the case of transient states at the nanoscale, its applicability is significantly limited. The limitation of the classical Fourier's theory was overcome by C. Cattaneo and P. Vernotte who developed the theory of non-Fourier heat conduction in 1958. Although this new theory has been used in various thermal science areas, it requires considerable mathematical skills for calculating analytical solutions. The aim of this study was the identification of a newer and a simpler type of solution for the hyperbolic partial differential equations of the non-Fourier heat conduction. This constitutes the first trial in a series of planned studies. By inspecting each term included in the proposed solution, the theoretical feasibility of the solution was achieved. The new analytical solution for the non-Fourier heat conduction is a simple exponential function that is compared to the existing data for justification. Although the proposed solution partially satisfies the Cattaneo-Vernotte equation, it cannot simulate a thermal wave behavior. However, the results of this study indicate that it is possible to obtain the theoretical solution of the Cattaneo-Vernotte equation by improving the form of the proposed solution.