• Title/Summary/Keyword: Index of agreement

Search Result 519, Processing Time 0.027 seconds

Flexural Behavior and Analysis of RC Beams Strengthened with Prestressed CFRP Plates (프리스트레스트 탄소섬유판으로 보강된 철근콘크리트 보의 휨 거동 및 해석)

  • Yang, Dong-Suk;Park, Jun-Myung;You, Young-Chan;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.467-474
    • /
    • 2007
  • In this paper, a total of 13 beams with bonding, anchorage system, amount of prestressing and span length as variables of experiment were tested in flexural test and analyzed in finite element analysis; one control beam, two simplified FRP-boned beams, four prestressed FRP-unbonded beams and four prestressed FRP-bonded beams. Also, a nonlinear finite element analysis of beams in the flexural test is performed by DIANA program considered material nonlinear of concrete, reinforcement and the interfacial bond-slip model between concrete and CFRP plates. The failure mode of prestressed CFRP plated-beams is not debonding but FRP rupture. RC members strengthened with external bonded prestressed CFRP plates occurred 1st and 2nd debonding of the composite material. After the debonding of CFRP plates occurs in bonded system, behavior of bonded CFRP-plated beams change into that of unbonded CFRP-plated beams due to fix of the anchorage system. Also, It was compared flexural test results and analytical results of RC members strengthened with CFRF plates. The ductility of beams strengthened by CFRP plates with the anchorage system is considered high with the ductility index of above 3. Analysis results showed a good agreement with experiment results in the debonding load, yield load and ultimate load.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • v.24 no.6
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.

The Effect of the Chemical Lateral Boundary Conditions on CMAQ Simulations of Tropospheric Ozone for East Asia (동아시아지역의 CMAQ 대류권 오존 모의에 화학적 측면 경계조건이 미치는 효과)

  • Hong, Sung-Chul;Lee, Jae-Bum;Choi, Jin-Young;Moon, Kyung-Jung;Lee, Hyun-Ju;Hong, You-Deog;Lee, Suk-Jo;Song, Chang-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.5
    • /
    • pp.581-594
    • /
    • 2012
  • The goal of this study is to investigate the effects of the chemical lateral boundary conditions (CLBCs) on Community Multi-scale Air Quality (CMAQ) simulations of tropospheric ozone for East Asia. We developed linking tool to produce CLBCs of CMAQ from Goddard Earth Observing System-Chemistry (GEOS-Chem) as a global chemistry model. We examined two CLBCs: the fixed CLBC in CMAQ (CLBC-CMAQ) and the CLBC from GEOS-Chem (CLBC-GEOS). The ozone fields by CMAQ simulation with these two CLBCs were compared to Tropospheric Emission Spectrometer (TES) satellite data, ozonesonde and surface measurements for May and August in 2008. The results with CLBC-GOES showed a better tropospheric ozone prediction than that with CLBC-CMAQ. The CLBC-GEOS simulation led to the increase in tropospheric ozone concentrations throughout the model domain, due to be influenced high ozone concentrations of upper troposphere and near inflow western and northern boundaries. Statistical evaluations also showed that the CLBC-GEOS case had better results of both the index of Agreement (IOA) and mean normalized bias. In the case of IOA, the CLBC-GEOS simulation was improved about 0.3 compared to CLBC-CMAQ due to the better predictions for high ozone concentrations in upper troposphere.

Development of a lateral flow dipstick test for the detection of 4 strains of Salmonella spp. in animal products and animal production environmental samples based on loop-mediated isothermal amplification

  • Wirawan Nuchchanart;Prapasiri Pikoolkhao;Chalermkiat Saengthongpinit
    • Animal Bioscience
    • /
    • v.36 no.4
    • /
    • pp.654-670
    • /
    • 2023
  • Objective: This study aimed to develop loop-mediated isothermal amplification (LAMP) combined with lateral flow dipstick (LFD) and compare it with LAMP-AGE, polymerase chain reaction (PCR), and standard Salmonella culture as reference methods for detecting Salmonella contamination in animal products and animal production environmental samples. Methods: The SalInvA01 primer, derived from the InvA gene and designed as a new probe for LFD detection, was used in developing this study. Adjusting for optimal conditions by temperature, time, and reagent concentration includes evaluating the specificity and limit of detection. The sampling of 120 animal product samples and 350 animal production environmental samples was determined by LAMP-LFD, comparing LAMP-AGE, PCR, and the culture method. Results: Salmonella was amplified using optimal conditions for the LAMP reaction and a DNA probe for LFD at 63℃ for 60 minutes. The specificity test revealed no cross-reactivity with other microorganisms. The limit of detection of LAMP-LFD in pure culture was 3×102 CFU/mL (6 CFU/reaction) and 9.01 pg/μL in genomic DNA. The limit of detection of the LAMP-LFD using artificially inoculated in minced chicken samples with 5 hours of pre-enrichment was 3.4×104 CFU/mL (680 CFU/reaction). For 120 animal product samples, Salmonella was detected by the culture method, LAMP-LFD, LAMP-AGE, and PCR in 10/120 (8.3%). In three hundred fifty animal production environmental samples, Salmonella was detected in 91/350 (26%) by the culture method, equivalent to the detection rates of LAMP-LFD and LAMP-AGE, while PCR achieved 86/350 (24.6%). When comparing sensitivity, specificity, positive predictive value, and accuracy, LAMP-LFD showed the best results at 100%, 95.7%, 86.3%, and 96.6%, respectively. For Kappa index of LAMP-LFD, indicated nearly perfect agreement with culture method. Conclusion: The LAMP-LFD Salmonella detection, which used InvA gene, was highly specific, sensitive, and convenient for identifying Salmonella. Furthermore, this method could be used for Salmonella monitoring and primary screening in animal products and animal production environmental samples.

Legal Institutional Improvement Measures for Revitalization of Change in Building use Officetel to Lifestyle Lodging Industry (오피스텔의 생활형 숙박업 용도변경 활성화를 위한 제도적 개선방안 연구)

  • Ho, Han-Cheol;Song, Ho-Chang
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.455-465
    • /
    • 2014
  • This study focuses on some institutional improvement for revitalization of change in building use of officetel to lifestyle lodging industry. First as analysis method, this study establishes a failure factor for change in building use of officetel to lifestyle lodging industry. Second, analyzes an urgent importance to improve it in aspect of a legal institution or management for revitalizing a change of building use of officetel to lifestyle lodging industry. As a result, a failure factor of change in building use from officetel to lifestyle lodging industry is deducted in 4 articles with 13 detailed index. As a result of AHP, 'existing contractor's 100% agreement condition' is the first place, 'commercial /semi-residential area in zoning' is the second place, 'relative cleanup zone' is the fourth place, 'late changes of building use by a complex licensing procedure' is the fifth place, 'operational risk of consignment' is the sixth place, 'deficiency in publicity of related institution' is the eighth place, 'lack of concept in lifestyle lodging industry of building code' is the ninth place, 'basic constructional condition such as parking lot sewage and fire protection system' is the tenth plce, 'installation of ventilation facility' is the eleventh place, 'installation of bathroom and shower room in each room' is the twelfth place, 'installation of kitchen facility' is the thirteenth place.

Analysis of Factors of IRRs and Spread on Korea's BTO Projects (우리나라 민간투자사업의 수익률과 가산금리의 결정요인 분석)

  • Ju, Jae-Hong;Ha, Heon-Gu;Park, Dong-Gyu
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.2
    • /
    • pp.135-150
    • /
    • 2010
  • This paper focuses on finding out which covenants are different among the concession agreements of Korean BTO projects and how these influenced IRR(Internal Rate of Return). That is, to figure out the political and economical determinants of IRR by analyzing the concession agreements which are the basic contract of implementing projects. As IRR is an index of profitability, so spread is an indicator of risk to collect debts. That's the reason why the analysis of spread is included. For the empirical analysis, the data of concession agreements for 75 projects and financial models are used. These 75 concession agreements are contracted from 1995 to 2008. The dependent variables are after tax nominal IRR and the spread of long term interest rates of 75 BTO projects. The independent variables are project's proceeding factors, the feasibility variables, the variables related to financial character and the variables related to covenants or the government's policy. The analysis shows that IRR has been influenced by the equity level of financial investors, the national government managed projects, the projects with minimum revenue guarantee (MRG), etc. And the equity level of financial investors, the national government managed projects and the implementation of supplementary project have an effect on spread also.

Kinetic Modelling for the Prediction of Shelf-life of Kimchi Based on Total Acidity as a Quility Index (총산도를 기준한 김치의 품질수명 예측모델 연구)

  • Lee, Kwang-Hyuck;Cho, Hyung-Yong;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.306-310
    • /
    • 1991
  • A simplified mathematical model to estimate changes in total acidity of Chinese cabbage kimchi during fermentation was developed as a function of temperature and salt concentration. Assuming that tolerable acceptability reached at 0.75% total acidity, the shelf-life of kimchi was predicted by the model. The predicted value was in good agreement with the actual shelf-life measured by organoleptic tests.

  • PDF

Application of Integrated Modelling Framework Consisted of Delft3D and HABITAT for Habitat Suitability Assessment (생물서식지 적합성 평가를 위한 Delft3D와 HABITAT 모델의 연계 적용)

  • Lim, Hyejung;Na, Eun Hye;Jeon, Hyeong Cheol;Song, Hojin;Yoo, Hojun;Hwang, Soon Hong;Ryu, Hui-Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.217-228
    • /
    • 2021
  • This paper discusses a methodology where an integrated modelling framework is used to quantify the risk derived from anthropic activities on habitats and species. To achieve this purpose, a tool comprising the Delft3D and HABITAT model, was applied in the Yeongsan river. Delft3D effectively simulated the operational condition and flow of weirs in river. In accuracy evaluation of the Delft3D-FLOW, the Bias, Pbias, Mean Absolute Error (MAE), Nash-Sutcliffe Efficiency (NSE), and Index of Agreement (IOA) were used, and the result was evaluated as grade above 'Satisfactory'. The HABITAT calculated Habitat Suitability Value (HSV) for the following eight species: mammal, fish, aquatic plant, and benthic macroinvertebrate. An Area was defined as a suitable habitat if the HSV was larger than 0.5. HABITAT was judged accurately by measuring the Correct Classification rate (CCR) and the area under the ROC curve (AUC). For benthic macroinvertebrate, the CCR and AUC were 77% and 0.834, respectively, at thresholds of 0.017 and 4 inds/m2 for HSV and individuals per unit area. This meant that the HABITAT model accurately predicted the appearance of the benthic macroinvertebrates by approximately 77% and that the probability of false alarms was also very low. As a result of evaluating the suitability of habitats, in the Yeongsan river, if the annual "lowest level" (Seungchon weir: 2.5 EL.m/ Juksan weir: -1.35 EL.m) was maintained, the average habitat improvement effect of 6.5%P compared to the 'reference' scenario was predicted. Consequently, it was demonstrated that the integrated modelling framework for habitat suitability assessment is able to support the remedy aquatic ecological management.

Optimization of Time to Activate Time-Temperature Integrator (TTI) in Cold Chain System of Alaska Pollack (명태의 냉장유통 단계에서 시간-온도이력 지시계(TTI) 부착시점의 최적화)

  • Choi, Jung-Hwa;Park, Soo Yeon;Kang, Jin Won;Hwang, Sang Min;Kim, Min Jung;Kim, Min Jung;Lee, Man Hi;Lee, Seung Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.3
    • /
    • pp.97-102
    • /
    • 2014
  • It was mathematically analyzed at which steps to activate TTI in the cold chain for Alaska pollack, assuming that the performance of a commercial TTI product, and Fresh-check, could not always be optimized for the pollack. Three places were selected for the TTI activation, such as on fishing ship, Busan cooperative fish market, and mart. First, the kinetic and Arrhenius temperature dependent models were experimentally built under isothermal conditions. The color index of TTI and the level of Pseudomonas spp. of pollack were measured at time intervals. Second, the resultant models were used in the mathematical calculations for dynamic temperature conditions included in the cold chain. As a result, the TTI activated at the mart place showed the best agreement between the spoilage time of the pollack and the time for the TTI color to reach its end-point. It was therefore found that it is practically important to optimally select the TTI activation place or time when using a commercial TTI product.

  • PDF

A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables (22 kV 케이블의 누설전류 및 절연저항의 선형적 변화)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.169-173
    • /
    • 2015
  • This study is to predict the life exponent by measuring, over 7 years, the insulation resistance of high-voltage cables in 22 kV operation for 13 years. We found out the lifetime index in order to determine the time-dependent trend of deteriorating performance of power cables. The insulation resistances decreased according to elapsed time. We found that: the initial measurements of the cable systems were in agreement with the deterioration properties of the Arrhenius Law. By analyzing the life curve of the cable system, we also verified that the value of the life exponent (n) in the v-t characteristics defined by Weibull distribution has values from 10 to 11. When designing the cable system, the initial value of life exponent was chosen as 9 without any grounding. We have verified that the theoretical grounding based on the design safety of n=9 was actually the best one available. In the short term, we apply our research result to the diagnosis and evaluation of the power cables. In the long run, however, we plan to reduce the cost of the installation and management of cable systems in operation at power stations.