• Title/Summary/Keyword: Index of Volume

Search Result 1,439, Processing Time 0.033 seconds

An Efficient Information Retrieval System for Unstructured Data Using Inverted Index

  • Abdullah Iftikhar;Muhammad Irfan Khan;Kulsoom Iftikhar
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.7
    • /
    • pp.31-44
    • /
    • 2024
  • The inverted index is combination of the keywords and posting lists associated for indexing of document. In modern age excessive use of technology has increased data volume at a very high rate. Big data is great concern of researchers. An efficient Document indexing in big data has become a major challenge for researchers. All organizations and web engines have limited number of resources such as space and storage which is very crucial in term of data management of information retrieval system. Information retrieval system need to very efficient. Inverted indexing technique is introduced in this research to minimize the delay in retrieval of data in information retrieval system. Inverted index is illustrated and then its issues are discussed and resolve by implementing the scalable inverted index. Then existing algorithm of inverted compared with the naïve inverted index. The Interval list of inverted indexes stores on primary storage except of auxiliary memory. In this research an efficient architecture of information retrieval system is proposed particularly for unstructured data which don't have a predefined structure format and data volume.

A study of Efficient Access to homepage

  • Yamagata, Osamu.;Sakamoto, Masahiro.;Tsuda, Kazuo.
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.707-710
    • /
    • 2000
  • WWW(World wide Web) is a place where many laymen receive and send the information at the worldwide. A visualization of WWW is very important as one of functions helping to retrieve and browse the information. However, as the information volume displayed at one time is limited by a screen size, it is useful to limit the volume of information capable for users to browse. In this report, we propose the page-index, which extract its information according to degree of user’s interest. This index is a numbers, which relate the user’s interest with verbal and structural characteristics of homepages. The homage-index constructed with sequence of this index are useful to help a user’s browsing. We constructed the estimating system about an article of commerce and really tried to estimate. From this trial, we verified the usefulness of the page-index, homepage-index.

  • PDF

THE EVALUATION OF SELLA TURCICA ON THE SHAPE AND VOLUME IN CLASS III PATIENTS : The Possibility of Sella Turcica as Class III Growth Prediction Indicator (성인 III급 부정교합자의 SELLA TURCICA의 형태 및 크기에 관한 연구 : SELLA TURCICA부피의 III급 부정교합 예측 지표로서의 가능성)

  • Yang, Won-Sik;Ha, Tai-Heon
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.203-217
    • /
    • 1998
  • Sella turcica contains pituitary gland that has influence on craniofacial growth. So, if the volume of sella turcica correlate to the function of Pituitary gland, we can assume that the volume of sella turcica in skeletal Class III patients has some difference to that of normal occlusion group. The purpose of this study was to evaluate the difference of shape and volume of sella turcica between normal occlusion group and Class III patients. The shape of sella turcica was Classified by Inaba method and the volume of sella turcica was measured in lateral and P-A cephalograms by Di Chiro method. To find out the possibility of the volume of sella turcica as diagnostic aid to predict Class III growth pattern, the correlation coefficients between the volume of sella and cephalometric variables were calculated. The results were as follows. 1. The volume of sella turcica in Class III patients is larger than that of normal occlusion groups 2. The volume of sella turcica in female was larger than that of male in Class III patients 3. The volume of sella turcica has close correlation with APDI, ANB, SNA, SNB, ODI, gonial angle, post. cranial base length 4. Sella Index (volume of sella / ant. cranial base length) can be a more accurate indicator that represent Class III growth pattern than volume of sella itself. 5. The morphologic pattern of sella turcica had no significant difference between two groups.

  • PDF

A Study on the Tariff Index of Mobile Telephony in Korea

  • Kim, Jin-Ki
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.74-77
    • /
    • 2000
  • Since the opening of the mobile telecommunications market to new entrants in 1996, the mobile telecommunications industry in Korea has transformed into a severely competitive market. Although there are numerous methods to evaluate the effects of the competition policy, the most relevant would be to measure the decreased degree of mobile service tariff. Also, after the Introduction of competition in the market, most carriers launched a variety of new tariff plans, which would satisfy the users′ traffic volume and pattern. Therefore, it is necessary to develop a "mobile tariff index" that would collectively consider all the various tariff plans. This paper aims to develop a mobile tariff Index that would accommodate all the various tariff plans provided by mobile carriers. To develop this mobile tariff index, mobile user′s will first be classified by their traffic volume, and then calculate the average tariffs per minute of each group of users, and lastly weight-average those tariffs per minute. And finally, this paper shows the mobile tariff index by considering those averaged tariffs and the carriers′ market shares to reflect the contribution of individual carriers and the users′ traffic volume.

  • PDF

Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck (두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석)

  • Kim, Dae Sup;Lee, Woo Seok;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • Purpose : To derive the most appropriate factors by considering the effects of the major factors when applied to the optimization algorithm, thereby aiding the effective designing of a ideal treatment plan. Materials and Methods : The eclipse treatment planning system(Eclipse 10.0, Varian, USA) was used in this study. The PBC (Pencil Beam Convolution) algorithm was used for dose calculation, and the DVO (Dose Volume Optimizer 10.0.28) Optimization algorithm was used for intensity modulated radiation therapy. The experimental group consists of patients receiving intensity modulated radiation therapy for the head and neck cancer and dose prescription to two planned target volume was 2.2 Gy and 2.0 Gy simultaneously. Treatment plan was done with inverse dose calculation methods utilizing 6 MV beam and 7 fields. The optimal algorithm parameter of the established plan was selected based on volume dose-priority(Constrain), dose fluence smooth value and the impact of the treatment plan was analyzed according to the variation of each factors. Volume dose-priority determines the reference conditions and the optimization process was carried out under the condition using same ratio, but different absolute values. We evaluated the surrounding normal organs of treatment volume according to the changing conditions of the absolute values of the volume dose-priority. Dose fluence smooth value was applied by simply changing the reference conditions (absolute value) and by changing the related volume dose-priority. The treatment plan was evaluated using Conformal Index, Paddick's Conformal Index, Homogeneity Index and the average dose of each organs. Results : When the volume dose-priority values were directly proportioned by changing the absolute values, the CI values were found to be different. However PCI was $1.299{\pm}0.006$ and HI was $1.095{\pm}0.004$ while D5%/D95% was $1.090{\pm}1.011$. The impact on the prescribed dose were similar. The average dose of parotid gland decreased to 67.4, 50.3, 51.2, 47.1 Gy when the absolute values of the volume dose-priority increased by 40,60,70,90. When the dose smooth strength from each treatment plan was increased, PCI value increased to $1.338{\pm}0.006$. Conclusion : The optimization algorithm was more influenced by the ratio of each condition than the absolute value of volume dose-priority. If the same ratio was maintained, similar treatment plan was established even if the absolute values were different. Volume dose-priority of the treatment volume should be more than 50% of the normal organ volume dose-priority in order to achieve a successful treatment plan. Dose fluence smooth value should increase or decrease proportional to the volume dose-priority. Volume dose-priority is not enough to satisfy the conditions when the absolute value are applied solely.

A Study on the Analysis of Export Structure in Jeollabuk-do for the Activation of Saemangeum New Port (새만금신항 활성화를 위한 전라북도 수출구조 분석에 관한 연구)

  • Min-Ju Song
    • Korea Trade Review
    • /
    • v.47 no.4
    • /
    • pp.293-309
    • /
    • 2022
  • The purpose of this paper is to analyze the import and export volume of Jeollabuk-do to establish a plan to activiation Saemangeum New Port. To this end, this study utilized the HHI(Herfindahl-Hirschman Index), LQ(Location Quotient) analysis using the annual data set from the Korea Trade Statistics Promotion Institution between 2015 to 2020. As a result, it has been confirmed that the degree of export volume concentration (HHI (Herfindahl-Hirschman Index)) in Jeollabuk-do has been increasing over the past 5 years. According to results of LQ(Location Quotient) analysis, Brazil had the highest index in the case of exporting countries, and Meat, edible meat offal (HS 2) had the highest index in the case of export items. This paper is meaningful in analyzing the export structure using import and export volumes and proposing a plan to improve the competitiveness of Saemangeum New Port.

A suggestion of Aortic wall Stiffness Evaluation Technique Independent on Changeable Blood Pressure : Aortic Distensibility Index (변화하는 혈압의 영향을 받지 않는 동맥 벽의 강화도 측정 방법 제안 : 대동맥 확장지수)

  • Seo, Jee-Hye;Choi, Dong-Ho;Wu, Zhuqing;Rienmueller, Rainer;Lee, Jong-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.151-158
    • /
    • 2008
  • To evaluate aortic wall stiffness without influence of different background blood pressure, a new technique was developed and verified. At eight swine descending aortae, volume-pressure measurement was performed using custom-made system. Based on averaged pressure-volume curve, aortic distensibility index was formulated to evaluate aortic wall stiffness regardless of variable blood pressure and aortic size. The variability of aortic distensibility index by pressure change was compared with other parameters for wall stiffness evaluation. Subsequently, the aortic distensibility index was calculated at 100 contrast-enhanced EBCT data sets of normal volunteers in regular health screening program. The measured aortic distensibility index was compared with age, coronary calcium score, and aortic calcium score. Between 50 and 360 mmHg of blood pressure, the coefficient of variance of aortic distensibility index was 22.00% as comparing with 88.99% of classical compliance. Based on age, aortic distensibility index showed correlation coefficient of 0.55, whereas classical compliance showed 0.26. The correlation coefficient with modified aortic calcification was 0.43. Linear regression study revealed statistical significance of correlation coefficients. The aortic distensibility index, the method to evaluate aortic wall stiffness free from variable blood pressure and aortic size, was developed and verified with significant practical feasibility.

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

Effect of Volume Fraction and Length of Fiber on the Mechanical Properties of Fiber Reinforced Concrete (섬유보강 콘크리트의 역학적 특성에 대한 섬유 체적비와 길이의 영향)

  • Yang, Keun-Hyeok;O, Seung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Fifteen concrete specimens were mixed and tested to explore the significance and limitation of appling the polyvinyl alcohol (PVA) fiber and steel fiber with end hook to concrete. Main parameters investigated were volume fraction and length of the fibers. The measured mechanical properties of fiber reinforced concrete are analyzed according to the equivalent fiber amount index explaining the adding amount and length of fibers. Test results showed that compressive strength of fiber reinforced concrete was higher than that of concrete with no fiber by $10{\sim}20%$. The normalized splitting tensile strength and flexural strength of PVA fiber reinforced concrete were similar to those of concrete with no fiber, whereas those of steel fiber reinforced concrete increased with the increase of the equivalent fiber amount index. In particular, much higher ductile behavior was observed in steel fiber reinforced concrete than in PVA reinforced concrete, indicating that the slope of descending branch of load-displacement relationship of steel fiber reinforced concrete decreased with the increase of the volume fraction and length of the fiber.

Vibration and stability of initially stressed sandwich plates with FGM face sheets in thermal environments

  • Chen, Chun-Sheng;Liu, Fwu-Hsing;Chen, Wei-Ren
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.251-261
    • /
    • 2017
  • In this paper, thermal effect on the vibration and stability of initially stressed sandwich plates with functionally graded material (FGM) face sheets is analyzed. Material properties of FGM face sheet are graded continuously in the thickness direction. The variation of FGM properties assumes a simple power law distribution in terms of the volume fractions of the constituents. The governing equations of arbitrarily initially-stressed sandwich plates including the effects of transverse shear deformation and rotary inertia are derived. The initial stress is taken to be a combination of a uniaxial extensional stress and a pure bending stress in the examples. The eigenvalue problems are formed to study the vibration and buckling characteristics of simple supported initially stressed FGM/metal/FGM plates. The effects of volume fraction index, temperature rise, initial stress and layer thickness of metal on the natural frequencies and buckling loads are investigated. The results reveal that the volume fraction index, initial stresses and layer thickness of metal have significant influence on the vibration and stability of sandwich plates with FGM face sheets.