• Title/Summary/Keyword: Indentation Method

Search Result 292, Processing Time 0.03 seconds

Evolution the surface morphology and mechanical properties of Polyimide induced by Ion Beam Irradiation

  • Ahmed, Sk. Faruque;Nho, Gun-Ho;Moon, Myoung-Woon;Han, Jun-Hyun;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.98-98
    • /
    • 2010
  • Ion beam irradiation has been extensively used for surface modification of polymers, glassy metals and amorphous and crystalline materials at micron and submicron scales. The surface structures created by exposure to an ion beam range from dots, steps and one-dimensional straight wrinkles to highly complex hierarchical undulations and ripples. In general, the morphology of these nanoscale features can be selected by controlling the ion beam parameters (e.g. fluence and acceleration voltage), making ion beam irradiation a promising method for the surface engineering of materials. In the work, we presented that ion beam irradiation results in creation of a peculiar nanoscale dimple-like structure on the surface of polyimide - a common polymer in electronics, large scale structures, automobile industry, and biomedical applications. The role of broad Ar ion beam on the morphology of the structural features was investigated and insights into the mechanisms of formation of these nanoscale features were provided. Moreover, a systematic experimental study was performed to quantify the role of ion beam treatment time, and thus the morphology, on the coefficient of friction of polyimide surfaces covered by nanostructure using a tribo-experiment. Nano-indentation experiment were performed on the ion beam treated surfaces which shows that the hardness as well as the elastic modulus of the polyimide surface increased with increase of Ar ion beam treatment time. The increased of hardness of polyimide have been explained in terms of surface structure as well as morphology changes induced by Ar ion beam treatment.

  • PDF

A Study on the Diagnostic Significance of Hepatoscintigram with Colloidal Gold in Parenchymal Liver Disease (간실질(肝實質) 병변(病變)에 대(對)한 간주사(肝走査) (Hepatoscintigram with $^{198}Au$ colloid)의 진단적(診斷的) 가치에 대한 고찰)

  • Shin, Dong-Ho;Lee, Min-Ho;Kim, Mok-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.63-72
    • /
    • 1982
  • Hepatoscintigram has been a useful diagnostic method for the liver diseases since 1953, but reasonable diagnostic criteria for parenchymal liver diseases are not yet accurately established. For the purpose of searching for more advanced diagnostic criteria for various types of live disease by the liver scan, a retrospective study was made of 272 cases who underwent both hepatoscintigram with 198 Au colloid and liver biopsy in Hanynag University Hospital from Jan., 1978 to Dec., 1981. The results were as follows: 1. Fuzzy margin (irregular indentation of the liver margin) in the hepatoscintigram was noted in 226 cases (97.79%). 2. Of 35 cases with fuzzy margin only, 28 cases (80%) revealed mild parenchymal liver disease, such as acute hepatitis or chronic persistent hepatitis by the liver biopsy. 3. Mottling change (209 cases) was always accompanied by fuzzy margin except only one case, and 31 cases (86.1%) of fuzzy and mottling cases (36 cases) showed mild parenchymal liver disease. 4. Configuration change (193 cases) was usually accompanied with other changes and espicially 104 cases had configuration change with fuzzy and mottling changes. 73 cases (88.44%) of 86 cases with severe configuration change revealed advanced parenchymal liver disease on biopsy. If liver scan showed mild configuration change, we could not decide the type of liver disease only liver scan, and so further studies are needed. 5. Splenic uptake was noted in 34 cases (40.48%) of 84 cases with advanced parenchymal liver disease, and the degree of splenic uptake was for the most part morderate or severe; whereas splenic uptake was noted in 18 cases (16.51%) of the mild parenchymal liver disease (109 cases), and the degree of splenic uptake was largely mild.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

EFFECT OF $CEO_2$ ADDITION IN GLASS COMPOSITION ON THE STRENGTH OF ALUMINA-GLASS COMPOSITES (알루미나-유리 복합체용 글래스의 조성에서 $CeO_2$의 함량변화가 강도에 미치는 영향)

  • Lee, Hwa-Jin;Song, Kwang-Yeob;Kang, Jeong-Kil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.595-605
    • /
    • 2000
  • Dental ceramics have good aesthetics, biocompatibility, low thermal conductivity, abrasion resistance, and color stability. However poor resistance to fracture and shrinkage during firing process have been limiting factors in their use, particularly in multiunit ceramic restorations. A new method for making all-ceramic crowns that have high strength and low processing shrinkage has been developed and is referred to as the Vita In-Ceram method. This study was performed to investigate the effect of $CeO_2$ addition in borosilicate glasses on the strength of alumina-glass composites. Porous alumina compacts were prepared by slip casting and sintered at $1,100^{\circ}C$ for 2 hours. Dense composites were made by infiltration of molten glass into partially sintered alumina at $1,140^{\circ}C$ for 4 hours. Specimens were polished sequentially from #800 to #2000 diamond disk. and the final surface finishing on the tensile side was received an additional polishing sequence through $1{\mu}m$ diamond paste. Biaxial flexure test was conducted by using ball-on-three-ball method at a crosshead speed of 0.5mm/min. To examine the microstructural aspect of crack propagation in the alumina-glass composites, Vickers-produced indentation crack was made on the tensile surface at a load of 98.0 N and dwell time of 15 sec, and the radial crack patterns were examined by an optical microscope and a scanning electron microscope. The results obtained were summarized as follows; 1. The porosity rates of partially sintered alumina decreased with the rising of firing temperature. 2. The maximum biaxial flexure strength of 423.5MPa in alumina-glass composites was obtained with an addition of 3 mol% $CeO_2$ in glass composition and strength values showed the aspect of decrease with the increase of $CeO_2$ content. 3 The biaxial flexure strength values of alumina-glass composites were decreased with rising the firing temperature. 4. Observation of the fracture surfaces of alumina-glass composites indicated that the enhancement of strength in alumina-glass composites was due to the frictional or geometrical inter-locking of rough fracture surfaces and ligamentary bridging by intact islands of materials left behind the fracture front.

  • PDF

Errors of Surface Image Due to the Different Tip of Nano-Indenter (나노인덴터 압입팁의 특성에 따른 표면 이미지 오차 연구)

  • Kim, Soo-In;Lee, Chan-Mi;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.346-351
    • /
    • 2009
  • Due to the decrease of line width and increase of the integration level of the device, it is expected that 'Bottom-up' method will replace currently used 'Top-down' method. Researches about 'Bottom-up' device production such as Nanowires and Nanobelts are widely held on. To utilize these technologies in devices, properties of matter should be exactly measured. Nano-indenters are used to measure the properties of nano-scale structures. Additionally, Nano-indenters provide AFM(Atomic Force Microscopy) function to get the image of the surface and get physical properties for exact position of nano-structure using this image. However, nano-indenter tips have relatively much bigger size than ordinary AFM probes, there occurs considerable error in surface image by Nano-Indenter. Accordingly, this research used 50nm Berkovich tip and 1um $90^{\circ}$ Conical tip, which are commonly used in Nano-Indenter. To find out the surface characteristics for each kind of tip, we indented the surface of thin layer by each tip and compared surface image and indentation depth. Then, we got image of 100nm-size structure by surface scanning using Nano-Indenter and compared it with surface image gained by current AFM technology. We calculated the errors between two images and compared it with theoretical error.

Compressive Strength and Residual Stress Evaluation of Stub Columns Fabricated of High Strength Steel (고강도강재 단주의 압축강도 및 잔류응력 평가)

  • Lee, Cheol-Ho;Kim, Dae-Kyung;Han, Kyu-Hong;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.23-34
    • /
    • 2012
  • In this study, stub columns subjected to concentrical and eccentrical loads were tested to check the applicability of the current local stability criteria (KBC2009, AISC2005) to 800MPa high-strength steel (HSA800). The key test variables in the concentrically loaded tests included the plate-edge restraints and the width-to-thickness ratio normalized by the yield strength of steel. Specimens made of ordinary steel (SM490) were also tested for comparative purposes. Eccentrically loaded stub column tests were conducted for a range of the P-M combinations by controlling the loading eccentricity. All the concentrically loaded specimens with non-compact and slender sections developed sufficient strengths according to the current local stability criteria. All the eccentrically loaded specimens with non-compact H sections also exhibited a sufficient P-M interaction strength that was even higher than that of compact H- section counterparts. Residual stresses were also measured by using the non-destructive indentation method to demonstrate their dependency or independency on the steel material's yield strength. The measured results of this study also indicated that the magnitude of residual stresses bears no strong relation to the yield strength of the steel material.

Collision Strength Assessment for Double Hull Type Product Carrier Using Finite Element Analysis (이중 선체 화학 운반선의 충돌 강도 평가)

  • Paik, Jeom-Kee;Lee, Jae-Myung;Lee, Kyung-Ern;Won, Suk-Hee;Kim, Chelo-Hong;Ko, Jae-Yong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.481-489
    • /
    • 2004
  • Ship collisions and grounding continue to occur regardless of continuous efforts to prevent such accidents. With the increasing demand for safety at sea and for protection of the environment, it is of crucial importance to be able to reduce the probability of accidents, assess their consequences and ultimately minimize or prevent potential damages to the ships and the marine environment. Numerical simulations for actual collision problem are conducted with a special attention with respect to finite element size, fracture criteria and material properties, which require a careful consideration to improve the accuracy. A parametric analysis varying colliding speed, angle, design loading condition is conducted using nonlinear finite element analysis method for 46,00 dwt Product/chemical carrier. The relationship between the absorbed energy and indentation are derived quantitatively using the insights observed from this study, and a novel design concept for assessing the anti-collision performance are proposed.

AN EXPERIMENTAL STUDY OF THE EFFECTS OF ION BEAM HIKING ON CERAMO-METAL BONDING (이온선 혼합법이 도재와 금속의 결합에 미치는 영향에 관한 실험적 연구)

  • Hong, Joon-Pow;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.245-265
    • /
    • 1991
  • The purpose of this study was to observe the changes of the elemental transmission and bond strength between the metal and porcelain according to various kinds of ion beam mixing method. ion beam mixing of $meta1/SiO_2$ (silica), $meta1/Al_2O_3$(alumina) interfaces causes reactions when the $Ar^+$ was implanted into bilayer thin films using a 100KeV accelerator which was designed and constructed for this study. A vacuum evaporator used in the $10^{-5}-10^{-6}$ Torr vacuum states for the evaporation. For this study, three kinds of porcelain metal selected, -precious, semiprecious, and non-precious. Silica and alumina were deposited to the metal by the vacuum evaporator, separately. One group was treated by two kinds of dose of the ion beam mixing $(1\times10^{16}ions/cm^2,\;5\times10^{15}ions/cm^2)$, and the other group was not mixed, and analyzed the effects of ion beam mixing. The analyses of bond strength, elemental transmissions were performed by the electron spectroscopy of chemical analysis (ESCA), light and scanning electron microscope, scratch test, and micro Vickers hardness tests. The finding led to the following conclusions. 1. In the scanning electron and light microscopic views, ion beam mixed specimens showed the ion beam mixed indentation. 2. In the micro Vickers hardness and scratch tests, ion beam mixed specimens showed higher strength than that of non mixed specimens, however, nonprecious metal showed a little change in the bond strength between mixed and non mixed specimens. 3. In the scratch test, ion beam mixed specimens showed higher shear strength than that of non treated specimens at the precious and semiprecious groups. 4. In the ESCA analysis, Au-O and Au-Si compounds were formed and transmission of the Au peak was found ion beam mixed $SiO_2/Au$ specimen, simultaneously, in the higher and lower bonded areas, and ion beam mixed $SiO_2/Ni-Cr$ specimen, oxygen, that was transmitted from $SiO_2\;to\;SiO_2/Ni-Cr$ interface combined with 12% of Ni at the interface.

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Effect of Metal Interlayers on Nanocrystalline Diamond Coating over WC-Co Substrate (초경합금에 나노결정질 다이아몬드 코팅 시 금속 중간층의 효과)

  • Na, Bong-Kwon;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.2
    • /
    • pp.68-74
    • /
    • 2013
  • For the coating of diamond films on WC-Co tools, a buffer interlayer is needed because Co catalyzes diamond into graphite. W and Ti were chosen as candidate interlayer materials to prevent the diffusion of Co during diamond deposition. W or Ti interlayer of $1{\mu}m$ thickness was deposited on WC-Co substrate under Ar in a DC magnetron sputter. After seeding treatment of the interlayer-deposited specimens in an ultrasonic bath containing nanometer diamond powders, $2{\mu}m$ thick nanocrystalline diamond (NCD) films were deposited at $600^{\circ}C$ over the metal layers in a 2.45 GHz microwave plasma CVD system. The cross-sectional morphology of films was observed by FESEM. X-ray diffraction and visual Raman spectroscopy were used to confirm the NCD crystal structure. Micro hardness was measured by nano-indenter. The coefficient of friction (COF) was measured by tribology test using ball on disk method. After tribology test, wear tracks were examined by optical microscope and alpha step profiler. Rockwell C indentation test was performed to characterize the adhesion between films and substrate. Ti and W were found good interlayer materials to act as Co diffusion barriers and diamond nucleation layers. The COFs on NCD films with W or Ti interlayer were measured as less than 0.1 whereas that on bare WC-Co was 0.6~1.0. However, W interlayer exhibited better results than Ti in terms of the adhesion to WC-Co substrate and to NCD film. This result is believed to be due to smaller difference in the coefficients of thermal expansion of the related films in the case of W interlayer than Ti one. By varying the thickness of W interlayer as 1, 2, and $4{\mu}m$ with a fixed $2{\mu}m$ thick NCD film, no difference in COF and wear behavior but a significant change in adhesion was observed. It was shown that the thicker the interlayer, the stronger the adhesion. It is suggested that thicker W interlayer is more effective in relieving the residual stress of NCD film during cooling after deposition and results in stronger adhesion.