• Title/Summary/Keyword: Inclination Angle

Search Result 756, Processing Time 0.033 seconds

Correction of Transverse Discrepancy with Slowly Maxillary Expansion by Hyrax type expander in Adult Patient (성인에서 Hyrax 장치로 완속상악확장하여 폭경부조화를 개선한 증례)

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Park, Soo-Byung;Son, Woo-Sung
    • The Journal of the Korean dental association
    • /
    • v.55 no.6
    • /
    • pp.400-410
    • /
    • 2017
  • Approximately 30% of adult patients who want orthodontic treatment have transverse discrepancy with insufficient width of the maxilla. Particularly, in Class III patients requiring orthognathic surgery, the frequency of insufficient width of the maxillary arch related to respiratory problems is high. We report a case of non-surgical maxillary expansion using a Hyrax type expander with an orthognathic surgery, based on the reports that the ratio of non-fused midpalatal suture is not high in adults. A 30 years and 2 months old woman with a long face showed an Angle Class III with a vertical growth pattern. Class III molar and canine relation, anterior edge bite, and mandibular incisor compensatory lingual inclination were observed. The posterior buccal overjet seemed to be appropriate, but I diagnosed that there was a transverse discrepancy, for the following reasons. The inter-canine and inter-molar widths were sufficient but excessive lingual inclination of the mandibular molars was observed when assessing the bucco-lingual inclination based on the center of resistance of the maxillary and mandibular first molar. For this reason, it was expected that intercuspal interference would occur during orthodontic decompensation. Therefore, slow maxillary expansion using Hyrax type expander was performed and 2-jaw rotation surgery was performed to improve aesthetic and occlusion. Adults can also improve width discrepancy by non-surgical methods, which can avoid SARPE requiring additional surgery or segmental surgery lacking stability and predictability.

  • PDF

Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Rhi, Seok-Ho;Yoo, Seong-Yeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • This paper is to study the heat transfer performance of the copper-water heat pipe with screen wicks. Recently, the semiconductor capacity of an electronic unit becomes larger, but its size becomes much smaller. As a result, a high- performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling waters and the mesh number of screen wicks. The distilled water was used as a working fluid. Based on the experimental results, when the copper-water heat pipe of 6mm diameter is used at the top heat mode, the heat transfer performance of 100 mesh 2 layers heat pipe is better than that of 150 and 200 mesh. The thermal resistance of the two layers with the 100-mesh screen was 0.7-$0.8^{\circ}C$/W.

A Study on the Effective Free Surface of Fluid Cargo (유동화물의 유효자유표면에 관한 연구)

  • Hur, I.;Wang, J.S.
    • Journal of the Korean Institute of Navigation
    • /
    • v.11 no.2
    • /
    • pp.73-88
    • /
    • 1987
  • It is well known that the height of tank metacenter above the centroid of fluid in a tank is given by i/v where I is the inertia moment of free surface and v is the fluid volume. It is supposed in this formula that the inclination of ship is small and that the free surface of fluid do not touch the top and the bottom of tank. It the inclination of ship is large, the height of tank metacenter may be possibly greater than that given by i/v. The height of tank metacenter is smaller than i/v when the free surface of fluid touch the top or the bottom of tank. The reasonable method to calculate the height of tank metacenter is presented in this paper and prepared in FORTRAN program by FUNCTION EFFRES. The approximate formula was also developed and given by $g_m=(1+\frac{2}{1}tan^2\theta)[1-EXP\{-12(\frac{\alpha(1-\alpha)k}{tan\theta})^{1.25}\}]\frac{i}{v}$ where $g_m$ is the distance from the centroid of fluid to the tank metacenter, $\theta$ is inclined angle of ship, $\alpha$ is the ratio of filled volume to tank capacity and k is the ratio of the depth to the width of tank. The values calculated by the approximate formula given in this paper were compared with the exact values from the computer program and proved out to be sufficiently precise for practical use.

  • PDF

Constant speed, variable ascension rate, helical trajectories for airplanes

  • Labonte, Gilles
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.1
    • /
    • pp.73-105
    • /
    • 2018
  • A particular type of constant speed helical trajectory, with variable ascension rate, is proposed. Such trajectories are candidates of choice as motion primitives in automatic airplane trajectory planning; they can also be used by airplanes taking off or landing in limited space. The equations of motion for airplanes flying on such trajectories are exactly solvable. Their solution is presented, together with an analysis of the restrictions imposed on the geometrical parameters of the helical paths by the dynamical abilities of an airplane. The physical quantities taken into account are the airplane load factor, its lift coefficient, and the thrust its engines can produce. Formulas are provided for determining all the parameters of trajectories that would be flyable by a particular airplane, the final altitude reached, and the duration of the trajectory. It is shown how to construct speed interval tables, which would appreciably reduce the calculations to be done on board the airplane. Trajectories are characterized by their angle of inclination, their radius, and the rate of change of their inclination. Sample calculations are shown for the Cessna 182, a Silver Fox like unmanned aerial vehicle, and the F-16 Fighting Falcon.

Turbulent Natural Convection in a Square Enclosure Containing Internal Heat Generating Fluid (내부 발열유체를 가진 정사각 밀폐공간에서의 난류자연대류)

  • 이재헌;김석현;정종화;박만흥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.112-121
    • /
    • 1992
  • A numerical analysis was carried out to study two-dimensional turbulent natural convection in a square enclosure containing fluid of Prandtl number 6.05 within internal energy sources. The square enclosure was bounded by four rigid planes of constant equal temperature. Inclination angles of 0, 15, 30 and 45 deg. from the horizon for Rayleigh numbers from 1 * 10$^{6}$ to 1 * 10$^{9}$ were studied. Local and average Nusselts numbers are obtained on all four walls. If inclination angle exists, the average Nusselt number appears in increasing order at bottom, left, right and top wall.

Numerical study for the characteristics of diesel spray impinging on a wall (벽에 충돌하는 디젤분무의 특성에 대한 수치적 연구)

  • Yang, Hui-Cheon;Jeong, Dong-Hwa;Yu, Hong-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.5
    • /
    • pp.661-671
    • /
    • 1998
  • It is unavoidable that the fuel spray impinges on the wall of piston cavity in a compact high-pressure D.I. diesel engine. Therefore the characteristics of impinging spray are the very significant information on the consideration and the simulation of its combustion processes including the formation mechanism of exhaust emission and the design of the combustion chamber. In this paper, the numerical simulation was performed to study the characteristics of impinging spray. The spray-wall impingement model used is Watkins and Park's model. Calculation parameters are the inclination angles and the ambient pressures. As the inclination angle increases, the impinging spray develops mainly to the direction of the downstream and scarcely flows to that of the upstream. The shape on the wall of the impinging spray is the circle in the case of the normal impingement, while it is the ellipse in that of the oblique impingement. As the ambient pressure increases, the growth of impinging spray on the wall in the radial direction decreases owing to the increase in the resistance of the ambient.

THE SELECTION OF ALTITUDE AND INCLINATION FOR REMOTE SENSING SATELLITES (원격탐사 위성의 고도와 궤도기울기 결정)

  • 이정숙;이병선
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.244-255
    • /
    • 1995
  • The success of a satellites mission is largely depended upon the choice of an appropriate orbit. In the case of a remote sensing satellite which observes the Earth, there exits an optimum solar elevation angle depending on the mission. Therefore a sun-synchronous orbit is suitable for a remote sensing mission. The second-order theory for secular perturbation due to non-symmetric geopotential was described. To design a sun-synchronous orbit, a constraint condition on regression of node was derived. A algorithm to determine the altitude and the inclination was introduced using this constraint condition. As practical examples, the altitudes and the inclinations of four remote sensing satellites were calculated. The ground tracks obtained by the orbit propagator were used to verify the resulting sun-synchronous orbital elements.

  • PDF

Application and its reinforcing effect of soil nailed-drilled shafts (Soil Nail로 보강된 현장타설말뚝의 적용성 및 보강효과 분석)

  • Jeong, Sang-Seom;Kim, Byung-Chul;Lee, Dae-Soo;Kim, Dae-Hong;Kim, Dae-Hak
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.50-57
    • /
    • 2004
  • In this study reinforcing effect of soil nailed-drilled shafts subjected to axial and lateral loads were evaluated. Special attention was given to the reinforcing effects of soil nails placed from the drilled shafts to surrounding weathered- and soft-rocks based on model tests, numerical analyses and load tests. The model tests and numerical analyses are conducted to analyze the reinforcing effect of various conditions of number, inclination, position and length. The results of 1/40 scale model tests and numerical analyses show that as the number of reinforcing level increases, the incremental effect of reinforcement tends to increase, whereas the reinforcing effect on relative position is negligible. In addition there is a reinforcing effect as the inclination angle increaes up to 30 degrees. Based on the results of tensile load tests, soil nailed-drilled shafts has a considerably smaller settlement to reach the ultimate level when compared with the result of un-reinforced drilled shafts. For compression tests, there is a reinforcing effect of about 200% measured.

  • PDF

A STUDY OF THE TEMPOROMANDIBULAR JOINT ON THE PANTOMOGRAPH (파노라마사진에 의한 측두하악관절의 연구)

  • Kim Mee Kyung;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.167-176
    • /
    • 1988
  • This study was designed to evaluate the morphology of the temporomandibular joint components and dentofacial characteristics of patients with clicking and painful temporomadibular joint. The materials consisted of 80 conventional pantomographs in normal an symptomatic individuals aged 18-23 and divided into 2 groups by symptom of temporomandibular joint. The results were as follows; 1. In morphologic analysis of condylar head, type Ⅰ (anterior, posterior smooth curve) was most dominant in both group(58.75%, 55.0%) and asymmetrical condylar shape was predominant in symptomatic group (18 cases, 45%). 2. In symptomatic group, the condylar width were slightly lesser and the ratio of condylar height to height of condyle-ramus were larger than those of normal group. 3. Vertical overlap of central incisor of symptomatic group was slightly larger than that of normal group. There was significant differences between each group in mandibular midline deviation. 4. The symptomatic group tended to steep mandibular plane angle and the degree of condylar path and condylar axis of normal group were larger than those of symptomatic group. 5. The condylar width was inversely correlated with inclination of condylar path and inclination of condylar path was correlated with condylar axis in both groups.

  • PDF

Characteristics of Ball End Milling and Rotary Die-sinking Electrical Discharge Machining for the Cutting Inclination Location (가공경사면 위치에 따른 볼엔드밀가공과 회전식 형조방전가공 특성)

  • 왕덕현;김원일;박성은;박창수
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.5
    • /
    • pp.73-80
    • /
    • 2002
  • In this study, work materials of the ree form surface shape was machined by ball end mill cutter according to the change of cutting location and depth, and the acquired data of cutting force, tool deflection and shape accuracy were analyzed. Cutting force results were obtained with tool dynamometer and tool deflection values were measured by a couple of eddy-current sensors. Shape accuracy was obtained by roundness tester and surface profile measuring machine. As inclination angle was decreased, cutting force was increased. Cutting force showed large value at $105^{\circ}$ and $150^{\circ}$. Tool deflection was less at down milling than at up milling, decreased at 45$^{\circ}$ and 120$^{\circ}$, and shown large tool deflection at $150^{\circ}$. Roughness values were found to be bad in the inside of surface shape tool deflection. Surface accuracy was obtained better precision in down milling than in up milling.