• Title/Summary/Keyword: Inclination Angle

Search Result 756, Processing Time 0.027 seconds

Performance Improvement of the Horizontal Control System for a Tractor Implement Using Sensor Signal from the Front Axle

  • Ro, Young-Min;Moon, Jun-Hee;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2016
  • Purpose: Many tractors have adopted the horizontal control system designed to maintain the three-point mounted implements in horizontal position when they are tilted sideways. The control system rotates the implement in the opposite direction to the inclination of rear axle of the tractor. However, the current control system was found to have poor performance in accuracy and response. A new control system was therefore developed to improve the performance. Methods: The new control system was designed to get the response of the implement to be started earlier by using the tilt information from the front axle of the tractor. By this approach, the rotation of the implement can be adjusted as required to make it horizontal at the expected time, even though the response is slow. The optimal values of the control parameters for the new system were determined by computer simulation and validated by a performance test conducted with an obstacle of 120 mm height on a flat concrete surface. The performance of the control system was evaluated by the root mean square error (RMSE) of the rotation angle of the implement with respect to the actual inclination of the rear axle. Results: The new control system reduced the RMSE of the current control system by 44.6% indicating a high performance improvement. The inclination of the front axle was easily obtained from a sensor mounted on the front axle of the tractor and used as input to the new control system. Conclusions: The method of getting the response of the implement to be started earlier by utilizing the inclination information of the front axle can be applied to improve the performance of the current control system at least cost.

A Novel Least Square and Image Rotation based Method for Solving the Inclination Problem of License Plate in Its Camera Captured Image

  • Wu, ChangCheng;Zhang, Hao;Hua, JiaFeng;Hua, Sha;Zhang, YanYi;Lu, XiaoMing;Tang, YiChen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.12
    • /
    • pp.5990-6008
    • /
    • 2019
  • Recognizing license plate from its traffic camera captured images is one of the most important aspects in many traffic management systems. Despite many sophisticated license plate recognition related algorithms available online, license plate recognition is still a hot research issue because license plates in each country all round the world lack of uniform format and their camera captured images are often affected by multiple adverse factors, such as low resolution, poor illumination effects, installation problem etc. A novel method is proposed in this paper to solve the inclination problem of license plates in their camera captured images through four parts: Firstly, special edge pixels of license plate are chosen to represent main information of license plates. Secondly, least square methods are used to compute the inclined angle of license plates. Then, coordinate rotation methods are used to rotate the license plate. At last, bilinear interpolation methods are used to improve the performance of license plate rotation. Several experimental results demonstrated that our proposed method can solve the inclination problem about license plate in visual aspect and can improve the recognition rate when used as the image preprocessing method.

A Study on the Natural Convection from the Isothermal Square Beam Attached to an Adiabatic Plate (단열판에 부착된 등온 사각비임에서의 자연대류 열전달에 관한 연구)

  • Park, Jae-Lim;Kwon, Sun-Sok
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.61-68
    • /
    • 1991
  • Steady laminar natural convection heat transfer from the isothermal square beam attached to an adiabatic plate has been studied for various inclination angles of the adiabatic plate and Rayleigh number by using Mach-Zehnder interferometer in air. As the inclination angles change, the different temperature and fluid flow field were obtained by the ascending heated fluid and the adiabatic plate. In this study, the inclination angles were $0^{\circ}$(positive & negative), $45^{\circ}$(positive & negative), and $90^{\circ}$. The maximum total mean Nusselt number value was found at a positive inclination angle ${\theta}=45^{\circ}$.

  • PDF

Defects Length Measurement using an Estimation Algorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup;Kang, E-Sok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1452-1457
    • /
    • 2004
  • In this paper, a method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed to an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle to the image normal to the wall and thus, it enables the accurate measurement of the defect lengths only by using a single camera and a laser slit beam.

  • PDF

Defects Length Measurement Using an Estimation Agorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam (레이저 슬릿 빔의 경사각과 카메라 자세 추정 알고리듬을 이용한 벽면결함 길이측정)

  • Kim, Young-Hwang;Yoon, Ji-Sup;Kang, E-Sok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2002
  • A method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation, which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed as an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle as the image normal as the wall and thus, it enables the accurate measurement of the defect lengths by using a single camera and a laser slit beam.

A STUDY ON THE CHANGES OF PHARYNGEAL AIRWAY, HYOID BONE AND HEAD POSTURE BEFORE AND AFTER TONSILLECTOMY IN FUNCTIONAL CLASS III MALOCCLUSION PATIENTS (기능성 III급 부정교합자에서 편도 절제술 전 후의 pharyngeal airway, hyoid bone, head posture에 관한 연구)

  • Park, Won-seo;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.231-243
    • /
    • 1997
  • This study was carried out in order to find out the changes of the pharyngeal airway, hyoid bone and head posture before and after tonsillectomy in functional class III malocclusion patients. For this study, 21 Angle's class I patients and 21 Angle's class III patients, totally 42 subjects were chosen. The results were as follows; 1. In comparison to Class I group, tongue was more anteriorly and hyoid bone was more inferiorly positioned in functional Class III group 2. In comparison to pre-tonsillectomy, tongue was more posteriorly positioned and larger nasopharynx depth was shown in post-tonsillectomy. In post tonsillectomy, the hyoid bone was displaced posteriorly and superiorly and counterclockwise rotation was shown. 3. The level of significance for the correlation shown was 5 percent (p<0.05) indicating that: The change of nasopharyx depth was correlated to the inclination of lower incisors. Vertical change of tongue posture was correlated to the hyoid axis change. Vertical change of hyoid bone was correlated to the horizontal change of hyoid bone, craruocervical inclination. The change of craniocervical inclination was correlated to the inclination of lower incisors. 4. After the tonsillectomy, counterclockwise rotation of hyoid axis was associated with decease of hya-NL and large nasopharyngeal airway. High posture of the tongue was associated with decrease of hya-NL. Posterior posture of the tongue was associated with increase of h-hl,and decrease of hya-ba-n.

  • PDF

Numerical Studies on Combined VH Loading and Inclination Factor of Circular Footings on Sand (모래지반에서 원형기초의 수직-수평 조합하중 지지력과 경사계수에 대한 수치해석 연구)

  • Kim, Dong-Joon;Youn, Jun-Ung;Jee, Sung-Hyun;Choi, Jaehyung;Lee, Jin-Sun;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.3
    • /
    • pp.29-46
    • /
    • 2014
  • For circular rigid footings with a rough base on sand, combined vertical - horizontal loading capacity was studied by three-dimensional numerical modelling. A numerical model was implemented to simulate the swipe loading and the probe loading methods and an interpretation procedure was devised in order to eliminate the numerical error from the restricted mesh density. Using the Mohr-Coulomb plasticity model, the effect of friction angle was studied under the associated flow-rule condition. The swipe loading method, which is efficient in that the interaction diagram can be drawn with smaller number of analyses, was confirmed to give similar results with the probe loading method, which follows closely the load-paths applied to real structures. For circular footings with a rough base, the interaction diagram for combined vertical (V) - horizontal (H) loading and the inclination factor were barely affected by the friction angle. It was found that the inclination factors for strip and rectangular footings are applicable to circular footings. For high H/V ratios, the results by numerical modelling of this study were smaller than the results of previous studies. Discussions are made on the factors affecting the numerical results and the areas for further researches.

A study on the 3-D standard value of mandible for the diagnosis of facial asymmetry (안면비대칭 진단을 위한 하악골 3차원영상 계측기준치에 관한 연구)

  • Ahn, Jeong-Soon;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.91-105
    • /
    • 2005
  • For af accurate diagnosis and treatment planning of facial asymmetry, the use of 3-dimensional (3-D) image is indispensable. The purpose of this study was to get standard data for the 3-D analysis of facial asymmetry Computerized tomography (CT) was taken in the 60 normal occlusion individuals (30 male. 30 female) who did not have any apparent facial asymmetry. The acquired 2D CT DICOM data were input on a computer, and the reformatted 3-D images were created using a 3-D image software. Twenty three measurements were established in order to evaluate asymmetry; 15 ;omear measurements (6 for ramus length. 1 for condylar neck length, and 8 for mandibular body length) and 8 angular measurements (4 for gonial angle. 2 for frontal ramal inclination. and 2 for lateral ramal inclination) The right aid left difference of each measurement was calculated and analyzed. It is suggested that the right and left differences of the measurements obtained from the study could be used as references for the diagnosis of facial asymmetric patients.

The Analysis of Change Detection in Building Area Using CycleGAN-based Image Simulation (CycleGAN 기반 영상 모의를 적용한 건물지역 변화탐지 분석)

  • Jo, Su Min;Won, Taeyeon;Eo, Yang Dam;Lee, Seoungwoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.359-364
    • /
    • 2022
  • The change detection in remote sensing results in errors due to the camera's optical factors, seasonal factors, and land cover characteristics. The inclination of the building in the image was simulated according to the camera angle using the Cycle Generative Adversarial Network method, and the simulated image was used to contribute to the improvement of change detection accuracy. Based on CycleGAN, the inclination of the building was similarly simulated to the building in the other image based on the image of one of the two periods, and the error of the original image and the inclination of the building was compared and analyzed. The experimental data were taken at different times at different angles, and Kompsat-3A high-resolution satellite images including urban areas with dense buildings were used. As a result of the experiment, the number of incorrect detection pixels per building in the two images for the building area in the image was shown to be reduced by approximately 7 times from 12,632 in the original image and 1,730 in the CycleGAN-based simulation image. Therefore, it was confirmed that the proposed method can reduce detection errors due to the inclination of the building.

Effects of Transversus Abdominal Muscle Stabilization Exercise to Spinal Segment Motion on Trunk Flexion-Extension (복횡근 강화운동이 체간 신전-굴곡 시 척추 분절 운동에 미치는 영향)

  • Kim, Suhn-Yeop;Baek, In-Hyeub
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.63-76
    • /
    • 2003
  • This research was performed to compare spinal segment motion angle between low back pain (LBP) group and painless group during trunk flexion-extension and to investigate the effect of transversus abdominis strengthening exercise on spinal segment motion angle in LBP group. Nine subjects with LBP and ten subjects without LBP participated. Transversus abdominis strengthening exercise was performed in LBP group for three weeks, and spinal segment motion angles were compared before and after the exercise performance. Spinal segment motion angles were measured both in sitting and standing position. Results were as followed: 1) Subjects' average age was 24.79 years, height was 167.84 cm, and weight was 59.95 kg. 2) Spinal segment motion angle of T10/l1 was significantly higher in LBP group compared with painless group (p<.05) in sitting position during trunk flexion-extension. 3) In sitting position, whereas entire lumbar segment motion angles were lower in LBP group compared with painless group (p<.05), angle of L4/5 was higher in LBP group compared with painless group (p<.05). 4) There was no significant difference in thoracic segment motion angle in standing position. 5) After three weeks of transversus abdominis strengthening exercise, thoracic segment motion angle increased both in sitting and standing position (p<.05). 6) In painless group, there was no significant difference in entire spinal segment motion angles in sitting and standing position (p>.05). When spinal segment motion angles were compared between sitting and standing position, there were slight differences. In sitting position, there was no difference in spinal segment motion angle between LBP group and painless group while hip joint motion angle and sacral inclination angle of LBP group was lower than those of painless group (p<.05). In standing position, lumbar segment motion angle was significantly lower in LBP group than that of painless group. Transversus abdominis strengthening exercise influenced thoracic segment motion angle more significantly than lumbar segment motion angle.

  • PDF