• Title/Summary/Keyword: Incinerator

Search Result 372, Processing Time 0.022 seconds

Effect of Secondary Air on Flow and Combustion Characteristics in a Pyrolysis Melting Incinerator (열분해 용융소각로 연소실의 2차공기 주입 영향에 관한 전산해석 및 실험)

  • Jeon, Byoung-Il;Park, Sang-Uk;Shin, Dong-Hoon;Ryu, Tae-Woo;Jeon, Kum-Ha;Hwang, Jung-Ho;Lee, Jin-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.149-157
    • /
    • 2004
  • In the present paper we studied experimentally fundamental optimization of oxygen enriched pyrolysis melting incinerator, Characteristics of this system was confirmed dealing with the gas flow and combustion properties for the inside secondary air injection. The experiment setup has a disposal rate of 30kg/hr which was measured by the inside temperature and gas. Along with above experiments, the three-dimensional computation was employed to analyse the combustion fluid dynamics and gas residence time. Equations for turbulence and heat - transmission as well as chemical reactions were solved by using common codes. The experimental combustion chamber was composed of staged combustion types structure for reducing NOx. Finally, it was verified that the control of the secondary air and air ratio of thermo stack were important. In the computational analysis, it showed reasonable agreement with the experimental results regarding the temperature and discharged gas concentration.

  • PDF

Numerical Study for the Design of Biogas-fired Low Emission Cyclone Incinerator (바이오 가스 소각용 저공해 사이클론 소각기 개발을 위한 수치 해석적 연구)

  • 전영남;김시욱;백원석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.401-410
    • /
    • 2002
  • Concerns for energy conservation, environmental pollution, and the fact that organic wastes account for a major portion of our waste materials, have created the interest of biogas, which usually contains about 60 to 70 percent methane, 30 to 40 percent carbon dioxide, and other gases, including ammonia, hydrogen sulfide, mercaptans and other noxious gases. Cyclone combustors are used for homing a wide range of fuels such as low calorific value gas, waste water, sludge. coal, etc. The 3-dimensional swirling flow, combustion and emission in a tangential inlet cyclone incinerator under different inlet conditions are simulated using a standard k-s turbulence model and ESCRS (Extended Simple Chemically-Reacting System) model. The commercial code Phoenics Ver.3.4 was used for the present work. The main parameters considered in this work are inlet velocity and air to fuel ratio. The results showed that the change of operating conditions had an influence on the shape and size of recirculation zones, mixture fraction and axial velocity which are important factors for combustion efficiency and emission behavior. The application of this kind of computer program seams to be promising as a potential tool for the optimum design of a cyclone combustor with low emission.

Emission Characteristics of PCDD/Fs in MSW Incinerator(I) - The Effect of Air Pollution Control Device - (도시폐기물 소각공장에서의 다이옥신 배출특성(I) - 방지시설의 영향 -)

  • Kim, Jin-Beom;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1817-1824
    • /
    • 2000
  • This study is carried out to investigate the discharge characteristics of PCDD/Fs from municipal solid waste(MSW) incinerator, According to the results measured at several air pollution control devices(APCDs), the largest amount of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) are found at selective catalytic reduction (SCR) inlet. Therefore, it concludes that the electrostatic precipitator(EP) provides the appropriate condition for the formation of PCDD/Fs. The concentration of PCDD/Fs shows a large difference with the season. The concentration of PCDD/Fs in winter is higher than that of autumn, which suggests that the formation of PCDD/Fs is affected by the MSW components and the operation condition of municipal solid waste incinerator(MSWI).

  • PDF

VOLATILE ORGANIC COMPOUNDS MEASUREMENT IN THE BOUNDARY OF WASTE TREATMENT FACILITIES

  • Yim, Bong-Been;Kim, Sun-Tae
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.46-54
    • /
    • 2007
  • Concentrations of the principal volatile organic compounds, such as benzene, toluene, ethylbenzene, m,p,o-xylene, styrene, and chlorobenzene were measured at the solid waste treatment plants classified into four categories; municipal waste incinerator, municipal waste landfill site, industrial waste incinerator and industrial waste landfill site. The average concentration of VOCs in industrial waste treatment facilities was 33.43 ppb and was significantly higher than that measured at municipal waste treatment facilities (4.71 ppb). The average toluene concentrations measured at incinerators (13.05 ppb) were a little higher than those measured at landfill sites (11.54 ppb). The contribution of the waste treatment facilities to the concentration of benzene (0.35 ppb) and o-xylene (0.15 ppb) in the industrial area was relatively small. However, toluene measured in the industrial waste treatment facilities was the most abundant VOCs with the average concentration of 21.37 ppb. As a result of analyses of fingerprint, in cases of IISH and ILUS, a variety of compounds other than major VOCs were detected in high level. On the Pearson correlation analysis, the correlation was generally positive and some pairs of these VOCs were very strongly correlated (correlation coefficient > 0.75).

An Experimental Study on the Bed Combustion Phenomena in MSW(Municipal Solid Waste) Incinerator (폐기물 소각로 베드에서의 연소현상 관찰을 위한 실험적 연구)

  • Min, Jee Hyun;Shin, Donghoon;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.159-165
    • /
    • 1999
  • Experimental studies have been performed to observe the basic phenomena of waste bed combustion in MSW incinerator. A reduced scale apparatus was utilized to simulate the combustion behavior in real plant with 1-dimensional transient behavior at the experimental setup, which uses wet cubic wood with ash content as simulated waste. LHV (lower heating value) of solid fuel, fuel particle size and flow rate of combustion air were taken as important parameters of the bed combustion. For the quantitative analysis, FPR (flame propagation rate), TBT (total burn-out time) and PBT (particle burn-out time) was defined. LHV represent the capability of heat release of the fuel, so that a higher LHV results in faster reaction rate of the fuel bed, which is shown by higher FPR. Fuel particle size is related with surface area per unit mass as well as heat and mass transfer coefficient. As the particle size increases the FPR decreases owing to decreasing specific surface area. Air injection supplies oxygen to the reaction zone. However oversupply of combustion air increases convection cooling of the bed and possibly extinguishes the flame.

Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator (쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구)

  • Lee, Geum-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

A Study of the Sectionalizing for Pipe Deterioration Evaluation in Industrial Facilities (산업시설 배관 노후도 평가를 위한 배관 섹션화 방안 연구)

  • Min, Hyuk-Ki;Kim, Sang-Bum;Kim, Byung-Woo;Kim, Hyoung-Ki;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • In general, no particularly well-established standards have been in place so far, for the method of evaluating the deteriorated level of pipes and ducts of industrial facilities. For that reason, the evaluation depends upon various studies which are based on the analysis of the residual life, thickness thinning, closure rate, and scale thickness that measure a few specific positions of pipes. It also depends upon the expertise in business operation and the specific techniques conducted by the inspection companies and institutions. This research introduces the concept of measuring units per section and the selection method of measurement points per section. Furthermore, specific methodologies were developed to plan and analyze deterioration level of industrial pipes and ducts by engineers and managers using a section map. Consequently, applying the outcomes from this study to the plant equipment of the incineration facility resulted in saving 42% of the repairing and remodeling cost.

Numerical research for Gate Type Waste Incinerators In Environment energy facilities (환경에너지시설내 화격자식 소각로 수치해석 연구)

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

Numerical Study of Flow Characteristics in a Solid Particle Incinerator for Various Design Parameters of Injectors (고체 입자 소각로에서 분사기의 설계 인자에 따른 유동 특성에 관한 수치해석적 연구)

  • Son, Jin Woo;Kim, Su Ho;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1079-1089
    • /
    • 2013
  • The flow characteristics in a solid particle incinerator are investigated numerically for high burning rate of wastes. The studied incinerator employs both a swirl flow used in the furnace of powerplants and a design concept applied to a rocket combustor. As the first step, the non-reactive flow field is analyzed in the incinerator with primary and secondary injectors through which solid fuel and air are injected. The deflection angle of a primary injector, inclination angle of a secondary injector, and gap between the two types of injectors are selected as design parameters. The swirl number is adopted for evaluating the degree of swirl flow and estimated over wide ranges of three parameters. The swirl number increases with deflection angle, but it is affected little by inclination angle. Recirculation zones are formed near the injectors, and their size affects the swirl number. The swirl number decreases with the zonal size of recirculation. From the numerical results, the design points can be found with strong swirl flow.

Improvement of Working Surroundings in the Industrial Waste Incinerator (산업폐기물 소각플랜트의 작업환경개선)

  • Shon Byung-Hyun;Lee Gang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.431-439
    • /
    • 2006
  • A lot of particulate matter and an offensive odor are emitted during the operations of an industrial waste incinerator (IWI), especially pre_treatment and waste input processes. These pollutants affect the labor efficiency of an operator. Therefore, in this study. we have studied the improvement of working surroundings in the industrial waste incinerator by designing a new control system. A computational fluid dynamics has been used to find the diffusion flows of air pollutants (mainly particles and odor) to the working surroundings of the waste treatment complexes. The results obtained from the simulation analysis applied to the basic design on the points (and/or site) and types of pollution control devices. When pollutant control devices are constructed, the concentration of each pollutant at site 1 and 2 decreased about 83-97% for toluene, 48-72% for styrene, 75-87% for xylene, and 23-36% for ammonia, respectively. In addition, the PM-10 and TSP were decreased about 87% and 86% at site 3 (lower part of the waste input), 87% and 85% at site 4 (side part of the waste input), respectively. These indicated that the new control system had an excellent performance of particulate matter and odor removal and it could be applied to other waste treatment plant in place of an industrial waste incinerator.

  • PDF