Emission Characteristics of PCDD/Fs in MSW Incinerator(I) - The Effect of Air Pollution Control Device -
도시폐기물 소각공장에서의 다이옥신 배출특성(I) - 방지시설의 영향 -
- Kim, Jin-Beom (Division of Research & Development, G.P. Inc.) ;
- Lee, Woo-Keun (Division of Environmental & Biological Engineering, Kangwon National University)
- Received : 2000.02.28
- Accepted : 2000.08.07
- Published : 2000.10.30
Abstract
This study is carried out to investigate the discharge characteristics of PCDD/Fs from municipal solid waste(MSW) incinerator, According to the results measured at several air pollution control devices(APCDs), the largest amount of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) are found at selective catalytic reduction (SCR) inlet. Therefore, it concludes that the electrostatic precipitator(EP) provides the appropriate condition for the formation of PCDD/Fs. The concentration of PCDD/Fs shows a large difference with the season. The concentration of PCDD/Fs in winter is higher than that of autumn, which suggests that the formation of PCDD/Fs is affected by the MSW components and the operation condition of municipal solid waste incinerator(MSWI).
본 연구는 도시폐기물 소각장 배출가스 중의 다이옥신 배출특성을 알아보기 위해 수행되었다. 소각로 내의 각 방지장치에서 측정된 결과에 의하면, 촉매반응탑 입구에서 가장 많은 양의 다이옥신이 측정되었다. 따라서 전기집진기는 다이옥신이 생성되는데 적당한 조건을 제공하는 것으로 보인다. 다이옥신 농도는 계절에 따라 큰 차이를 보여 겨울에 측정된 다이옥신 농도가 가을 보다 높았는데, 도시폐기물의 조성, 소각로 운전조건 등이 다이옥신 생성에 영향을 주고 있음을 제시해 준다.