• Title/Summary/Keyword: Incident rate

Search Result 333, Processing Time 0.029 seconds

Analysis of the Factors influencing the performance of Cardiopulmonary Resuscitation (심폐소생술 수행에 영향을 미치는 요인 분석)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.55-78
    • /
    • 2005
  • The purpose of this study was to provide basic data for the improvement of the guidelines and training programs regarding the cardiopulmonary resuscitation performance of bystanders who can respond to the incidents in earlier times as the first responder of the cardiac arrest incident, by reviewing the performance of basic CPR and the influencing factors after providing 70 students of Department of Emergency Medical Technology with the CPR training. For the purpose of the study, the collected data were computerized and analyzed by SPSS-WIN program(ver. 10.1). The results for this study were as follows The duration of session between the groups in the BLS CPR were 3 minutes and 36 seconds, 2 minutes and 32 seconds respectively. The average compression number per minute were 24.3 times and 33,2 times respectively(p=.000), and the average compression rate per minute were 112 times and 122 times respectively(p=.000). The average ventilation number per minute were 3.54 times and 5.1 times respectively(p=.000). The errors in compression "Too shallow" were 20.73 times(34.6%) and 23,23 times(38,7%) out of 60 times in 4 cycles with the standard of 38 nun. In CPR performance results according to gender in the first episode, males showed better results in compression depth as 41.5 mm comparing to females average 38.2 mm(p=.015). When ventilation results were compared according to the use of FS, the average ventilation number per minute, total ventilation per minute and the average volume per episode were significantly higher when FS was not used(<.040), There was no significant difference in ventilation accuracy between two groups. According to the results, we need to improve and distribute portable barrier devices, and to be familiar with those devices. We need to enforce ventilations as well as to include compressions so that faster and more accurate CPR can be performed. Additionally, we need to exclude ventilation only cases, minimize the interference time of chest compression due to inaccurate ventilation, simplify or minimize the complicatedness of CPR performance and responding time related to breathing, provide first responders with various training programs such as initial assessment and ventilations only, or initial assessment and chest compression-only CPR and than provide advanced training with AHA BLS education including CPR for more than two people according to CPR skills and target characteristics.

  • PDF

Measurement of neutron spectra in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector (LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용한 MC50 사이클로트론의 중성자스펙트럼 측정)

  • Ha, Wi-Ho;Park, Seyoung;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jungho;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.143-148
    • /
    • 2013
  • Operational nuclear facilities such as nuclear power plants and particle accelerators show various neutron spectra according to the type of facilities and specific position. Necessities of neutron dose management and neutron monitoring for radiation protection of radiation workers in such a kind of facilities have continuously increased in recent years. Bonner sphere spectrometers are widely used for measurement of neutron spectra. Data on response function of neutron detector, default neutron spectra and count rates of Bonner sphere spectrometer are required to obtain unfolded neutron spectra in specific workplaces. In this study, we carried out measurement of neutron spectra produced in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector. Additionally, we estimated quantitative data on neutron flux, mean neutron energy and ambient dose equivalent rate according to the incident proton energies and positions in MC50 cyclotron.

A Study on the Optimum-Path for Traffic of Road Using GIS (GIS를 이용한 도로교통(道路交通)의 최적경로(最適經路) 선정(選定)에 관한 연구)

  • Oh, Myoung-Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.5 no.2 s.10
    • /
    • pp.131-144
    • /
    • 1997
  • Traffic jam densified day by day is phenomenon to occur lack of the road capacity in comparison with traffic density, but lack of the road cannot be concluded by main cause of traffic ism. Because the central function of a city would be concentrated upon the downtown and traffic demand would not be evenly distributed by the classification of an hour. Therefore, this study based on the fact that each driver will select the route generating traffic delay very low when path choice from origin to destination in travel plan estimating the quality of passage could be maintained the speed he want will approach to a characteristic grasp of a road, traffic, driver changing every moment by traffic-demand of road increased as a geometrical series with analysis a classification of a street, a intersection along the path on traffic density and highway capacity analysis the path using GIS techniques about complex street network, also will get the path of actual optimum for traffic delay trend creating under various condition the classification per a hour, a day of week and an incident through network such as analysis for traffic generation zone adjacent about street, intersection, afterward will expect the result increasing efficiency of the road-use through a good distribution of traffic by optimum-path choice, accordingly will prepare the scientific, objective, appropriate basis to decide the reasonable time of a road-widen and expansion through section analysis along a rate of traffic volume vs. road capacity.

  • PDF

Recovery of lingual nerve injury: retrospective observational study (설신경 손상 환자의 회복에 대한 후향적 연구)

  • Hong, Dong-Hwan;Lim, Ho-Kyung;Kim, Soung-Min;Kim, Myung-Jin;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.355-364
    • /
    • 2011
  • Introduction: This study evaluated nerve recovery through retrospective study of patients with lingual nerve damage. Patients and Methods: The patients who visited Seoul National University Dental Hospital for an injury to the lingual nerve from April 1988 to August 2009 were enrolled in this study (n=41). The relevance of various factors including the causes of damage, age, etc. was analyzed by the subjective improvement based upon questionnaires and the clinical records. The evaluation variants were a subjective assessment and neurosensory examination composed of the direction, contact threshold, two-point discrimination, pin prick, thermal discrimination and current perception threshold. Results: The causes of lingual nerve damage were an extraction of the lower third molar (75.6%), local anesthesia (9.7%), incision and drainage (4.88%), trauma (2.44%). The evaluation of subjective prognosis exhibited no difference in sensory improvement depending on the cause, age and gender. Based upon the subjective evaluation, 44.7% of patients showed sensory improvement. The first hospital visit from injury was shorter in the group showing subjective improvement (3.41 months) than those showing no improvement (5.24 months) (P=0.301). Thirty six out of 41 patients were treated with only conservative therapy and 5 patients were treated by surgical intervention. Neurosensory examinations revealed improvement, although not statistically significant, and the degree was higher in the subjectively improved group. The contact threshold discrimination showed the highest correlation with subjective improvement (P=0.069). Most of the sensory recovery was gained within 12 months and the degree of improvement at the tip of the tongue was higher than that of the dorsum (P<0.001). Conclusion: The damaged lingual nerve improved at a rate of 44.7% and mostly within 12 months after the incident. There was no difference between the subjective prognosis and neurosensory examination depending on the cause of damage, age and gender, whereas the contact threshold discrimination was the best variant that reflected the subjective prognosis statistically.

Discussion on Optimal Shape for Wave Power Converter Using Oscillating Water Column (진동수주형 파력발전구조물의 최적형상에 대한 검토)

  • Lee, Kwang-Ho;Park, Jung-Hyun;Baek, Dong-Jin;Cho, Sung;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.5
    • /
    • pp.345-357
    • /
    • 2011
  • Recently, as part of diversifying energy sources and earth environmental issues, technology development of new renewable energy using wave energy is actively promoted and commercialized around Europe and Japan etc. In particular, OWC(Oscillating Water Column) wave power generation system using air flow induced by vertical movement of the water surface by waves in an air-chamber within caisson is known as the most efficient wave energy absorption device and therefore, is one of the wave power generation apparatus the closest to commercialization. This study examines air flow velocity, which operates turbine(Wells turbine) directly in oscillating water column type wave power generation structure from two-and three-dimensional numerical experiments and discusses optimal shape of oscillating water column type wave power generation structure by estimating the maximum flow rate of air according to change in shape. The three-dimensional numerical wave flume was applied in interpretation for this study which is the model for the immiscible two-phase flow based on the Navier-Stokes Equation. From this, it turned out that size of optimal shape appears differently according to the incident wave period and air flow is maximized at the period where minimum reflection ratio occurs.

Minimum Burning Pressure of Emulsion Explosives (에멀젼폭약의 최소연소압력에 관한 연구)

  • 이승찬;고재순;이영호
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.79-84
    • /
    • 2004
  • It is well accepted that modem emulsion explosives are intrinsically much less sensitive than traditional products such as dynamites or black powder. However, they have still been involved in a significant number of accidental explosions. In October 1975, Canadian Research, Limited's, Energetic Research Laboratory in Quebec exploded. Although explanations for the incident varied, one logical explanation was that the pump used in transporting the emulsion dead headed, thereby turning mechanical work in to frictional heating under a zero flow rate. There is a minimum pressure required for combustion(MBP) to propagate in emulsion explosives. A stable deflagration may lead to a deflagration-to-detonation transition(DDT) in emulsion explosives. Tests were also performed on sensitized sampled consisting of 6 to 21% waters as well as 1 to 11% aluminium powder. It was founded the emulsion explosives consisting of 6% waters had the lowest minimum homing pressure(MBP) of 3 bar, and the 21% waters were unable to achieve sustained homing at pressures as high as 100 bar. The aluminium contained explosives tested here displayed a MBP higher than that of without emulsion. It appears that this test may offer a firm ground for the classification of emulsion explosives in view of the regulating the hazards associated with the various process used for their manufacturing and transport.

Evaluation of Residual Radioactivity and Dose Rate of a Target Assembly in an IBA Cyclotron (IBA 사이클로트론 표적집합체에서의 잔류 방사화 분석 및 선량률 평가)

  • Hwang, Seon Yong;Kim, Youngju;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.643-649
    • /
    • 2016
  • When a cyclotron produces $^{18}F^-$, accelerated protons interact with metal parts of the cyclotron machine and induces radioactivity. Especially, the target window and chamber of the target assembly are the main parts where long-lived radionuclides are generated as they are incident by direct beams. It is of great importance to identify radionuclides induced in the target assembly for the safe operation and maintenance of a cyclotron facility. In this study, we analyzed major radionuclides generated in the target assembly by an operation of the Cyclotron 18/9 machine and measured dose rates after the operation to establish the radiation safety guideline for operators and maintenance personnel of the machine. Gamma spectroscopy with HPGe was performed on samples from the target chamber and Havar foil target window to identify the radionuclides generated during the operation for production of $^{18}F^-$- isotope and their specific activity. Also, the dose rates from the target were measured as a function of time after an operation. These data will help improve radiological safety of operating the cyclotron facilities.

An Experimental Study of Wave Overtopping Characteristics on the Structure for Wave Overtopping Power Generating System (월파형 파력발전구조물의 월파 특성에 관한 실험적 연구)

  • Shin, Seung-Ho;Hong, Key-Yong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.8 s.114
    • /
    • pp.649-655
    • /
    • 2006
  • Waves progressing into the coastal area can be amplified, swashed and overtopped by a wave overtopping control structure, and it converts the kinetic energy of the waves to the potential energy with a hydraulic head above the mean sea level by conserving the overflow in a reservoir. Then the potential energy in the form of hydraulic head can be converted to electric power utilizing extremely low-head hydraulic turbine. This study aims to find the most optimal shape of wave overtopping structure which maximizes overtopping volume rate of sea water. Laboratory experiments for the performance evaluation of wave overtopping control structures were carried out in three dimensional wave tank, and the three dimensional structure models with planar wave concentration shapes(B/b) were manufactured into five classes, which were optimized by cross sectional parameters of the structure, ie, length of ramp(l), gradient of inclined ramp($cot{\phi}$) and freeboard height of the wave overtopping structure($h_e$) proposed by Shin and Hong(2005). The wave overtopping discharges were investigated with 20 incident wave conditions and wave directions of $0^{\circ},\;15^{\circ},\;30^{\circ}$.

Color Filter Based on a Sub-Wavelength Patterned Poly-Silicon Grating Fabricated using Laser Interference Lithography (광파장 이하의 주기를 갖는 다결정 실리콘 격자 기반의 컬러필터)

  • Yoon, Yeo-Taek;Lee, Hong-Shik;Lee, Sang-Shin;Kim, Sang-Hoon;Park, Joo-Do;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.20-24
    • /
    • 2008
  • A color filter was proposed and demonstrated by incorporating a subwavelength patterned 1-dimensional grating in poly silicon. It was produced by employing the laser interference lithography method, providing much wider effective area compared to the conventional e-beam lithography. A $SiO_2$ layer was introduced on top of the silicon grating layer as a mask for the etching of the silicon, facilitating the etching of the silicon layer. It was theoretically found that the selectivity of the filter was also improved thanks to the oxide layer. The parameters for the designed device include the grating pitch of 450 nm, the grating height of 100 nm and the oxide-layer height of 200 nm. As for the fabricated filter, the spectral pass band corresponded to the blue color centered at 470 nm and the peak transmission was about 40%. Within the effective area of $3{\times}3mm^2$, the variation in the relative transmission efficiency and in the center wavelength was less than 10% and 2 nm respectively. Finally, the influence of the angle of the incident beam upon the transfer characteristics of the device was investigated in terms of the rate of the relative transmission efficiency, which was found to be equivalent to 1.5%/degree.

Optimization of Optical Structure of Lightguide Panel for Uniformity Improvement of Edge-lit Backlight (엣지형 LED 백라이트의 균일도 향상을 위한 도광판의 광구조 최적화)

  • Lee, Jung-Ho;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.61-68
    • /
    • 2010
  • Optical simulation methods were applied to the edge-lit LED backlight for LCD TV applications in order to optimize the optical structure of the light guide plate(LGP), and thus to improve the uniformity properties by removing the bright spots caused by LED's. The edge-lit LED backlight consisted of three white LED's with a lamp cover, a light guide plate, and a reflection film. When there was no pattern on the entrance side surface of the LGP, the illuminance uniformity was sensitively dependent on the distance d between the LED and the entrance surface. The illuminance uniformity increased with d but its increasing rate slowed down when d was beyond ~ 1.5 mm. When micro-patterns such as a lenticular lens array (LLA) or a serration pattern were formed on the entrance surface, the illuminance uniformity was improved substantially even for the case of very small d. At the same simulation condition, the lightguide with serration pattern showed a better uniformity than that with LLA pattern. Additional improvement could be achieved by changing the refractive index of the micro-patterns. These results suggest that using micro-patterns is a very effective way to reduce the bright spots due to their refracting function for the concentrated incident rays onto the LGP.