• Title/Summary/Keyword: Incident Detection

Search Result 235, Processing Time 0.034 seconds

원자로 내부 검사용 수중로봇의 위치검출 시스템 구현 (Development of a Position Detection System for Reactor Underwater Robot)

  • 서용칠;김명환;이흥호;김승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.568-570
    • /
    • 2004
  • This paper presents a study of a position finding system using PSD Sensor and Pan/Tilt. The position of PSD(Position Sensitive Detector) sensor is calculated by the degree of pan-tilt and the difference in height between pan-tilt and PSD. For that, the DSP which control pan-tilt is used for precise operation. The PIC microcontroller process PSD sensor data that indicate light incident position. A user using computer can acquire the conditions of pan-tilt and PSD and issue an order.

  • PDF

Signal Generation Due to Alpha Particle in Hydrogenated Amorphous Silicon Radiation Detectors

  • Kim, Ho-Kyung;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.397-404
    • /
    • 1996
  • The hydrogenated amorphous silicon (a-Si : H) holds good promise for radiation detection from its inherent merits over crystalline counterpart. For the application to alpha spectroscopy, the induced charge collection in a-Si : H pin detector diodes ons simulated based on a relevant non-uniform charge generation model. The simulation was peformed for the initial energy and the range of incident alpha particles, detector thickness and the operational parameters such as the applied reverse bias voltage and shaping time. From the simulation, the total charge collection was strongly affected by hole collection as expected. To get a reasonable signal generation, therefore, the hole collection should be seriously considered for detector operational parameters such as shaping time and reverse voltage etc. For the spectroscopy of alpha particle from common alpha sources, the amorphous silicon should have about 70${\mu}{\textrm}{m}$ thickness.

  • PDF

자연모사를 통한 미세 고분자 포토닉 구조의 구면배열에 관한 연구 (Spherical arrangement of biomimetic polymer photonic structures)

  • 정기훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.403-404
    • /
    • 2007
  • Compound eyes in nature present intriguing topics in physiological optics due to their unique optical scheme for imaging. For example, a bee's eye has thousands of integrated photonic units called ommatidia spherically arranged along a curvilinear surface so that each unit points in a different direction. The omni-directionally arranged ommatidium collects incident light with a narrow range of angular acceptance and independently contributes to the capability of wide field-of-view (FOV) detection. Artificial implementation of compound eyes has attracted a great deal of research interest because the wide FOV exhibits a huge potential for medical, industrial, and military applications. So far, imaging with a FOV over $90^{\circ}$ has been achieved only with fisheye lenses which rely on bulky and expensive multiple lenses and require stringent alignment. In this talk, we will discuss about the spherical 3D arrangement of the photonic structures of biologically inspired artificial compound eyes in a small form-factor to have and the functional and anatomical similiarity with natural compound eyes.

  • PDF

적외선차단필터의 표면 검사를 위한 암시야 레이저산란에 대한 실험적 분석 (An Experimental Analysis on Dark-field Laser Scattering for the Surface Inspection of Infrared Cut-off Filters)

  • 김경범;한재철
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.76-83
    • /
    • 2007
  • The dark-field laser scattering system has been developed to inspect surface defects in infrared cut-off filters and then laser scattering characteristics against the defects are investigated. The qualitative analysis for the reliable and accurate detection performance is described through the correlation between incident angles of a laser and viewing ones of a camera. In this paper, reliable and important information with laser scattering is given for the surface defect inspection of IR filters. Its performance has been verified through various experiments.

Hydrogen concentration and critical epitaxial thicknesses in low-temperature Si(001) layers grown by UHV ion-beam sputter deposition.

  • Lee, Nae-Eung
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제3권2호
    • /
    • pp.139-144
    • /
    • 1999
  • Hydrogen concentration depth profiles in homoepitaxial Si(001) films grown from hyper-thermal Si beams generated by ultrahigh vacuum (UHV) ion-beam sputtering have been measured by nuclear reaction analyses as a function of film growth temperature and deposition rate. Bulk H concentrations CH in the crystalline Si layers were found tio be below detection limits, 1${\times}$1019cm-3, with no indication of significant H surface segregation at the crystalline/amorphous interface region. This is quite different than the case for growth by molecular-beam epitaxy (MBE) where strong surface segregation was observed for similar deposition conditions with average CH values of 1${\times}$1020cm-3 in the amorphous overlayer. The markedly decreased H concentrations in the present experiments are due primarily to hydrogen desorption by incident hyperthermal Si atoms. Reduced H surface coverages during growth combined with collisionally-induced filling of interisland trenches and enhanced interlayer mass transport provide an increase in critical epitaxial thicknesses by up to an order of magnitude over previous MBE results.

  • PDF

PSD센서를 이용한 모션캡쳐 시스템의 센서보정에 관한 연구 (A Study on the Sensor Calibration for Low Cost Motion Capture Sensor using PSD Sensor)

  • 김유건;최훈일;유영기;오춘석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.603-605
    • /
    • 2005
  • In this paper, we deal with a calibration method for low cost motion capture sensor using PSD (Position Sensitive Detection). The PSD sensor is employed to measure the direction of incident light from moving markers attached to motion body. To calibrate the PSD optical module, a conventional camera calibration algorithm introduced by Tsai. The 3-dimensional positions of the markers are measured by using stereo camera geometry. From the experimental results, the low cost motion capture sensor can be used in a real time system.

  • PDF

Performance Analysis of Suboptimal Receiver Combining Adaptive Array Antenna and Orthogonal Decision-Feedback Detector for DS/CDMA System

  • Cho, Young-pil;Yoo, Sung-Kyun;Lee, Hyung-ki;Kwak, Kyung-sup
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1354-1357
    • /
    • 2002
  • In this paper, we propose a suboptimal receiver combining adaptive array antenna and orthogonal decision-feedback detector in DS/CDMA system. Adaptive array antenna can cancel out undesired signal using beamforming scheme. However, if there are interfering signals from undesired users with the same incident angle as that of a desired user, an adaptive array antenna cannot suppress them. The proposed receiver can cancel out remaining interference from users having nearly the same beam pattern. And we employ Orthogonal Decision-Feedback Detector (ODFD) as multiuser detection. The ODFD performs as good as the decorrelating decision -feedback detector (DDD) with much less complexity. Simulation results show that the proposed system provides a significantly enhanced performance.

  • PDF

FUV Images and Physical Properties of the OES region

  • 조영수;민경욱;선광일
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.69.2-69.2
    • /
    • 2010
  • The far-ultraviolet (FUV) H2 and C IV emission images and spectra of Orion Eridanus Superbubble (OES) is hereby presented. The OES seems to consists of multiple phase through the detection of highly-ionized gas and pervasive neutral hydrogen. The former is traced by hot gas while the latter is traced by cold medium. A spectral image made with H2 fluorescent emission shows that the spatial distribution of hydrogen molecule is well correlated with the dust map. The model spectra was taken from a photodissociation region (PDR) radiation code which find a best suitable parameter such as hydrogen density, gas temperature and incident uv intensity of the radiation field. C IV emission is caused by intermediate temperature ISM about 10^4.5 K~10^6 K. Therefore we could get more clear evidence to reveal the structure of OES. Feature of spectra for the each sub region is also presented and discussed. The data were obtained with the Far-Ultraviolet Imaging Spectrograph (FIMS) and the whole data handling were followed by previous FIMS analysis.

  • PDF

초음파를 이용한 마멸표면 평가 (Ultrasonic Evaluation of Worn Surface)

  • 안효석;김두인
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제30회 추계학술대회
    • /
    • pp.233-239
    • /
    • 1999
  • The feasibility of an ultrasonic technique using a pulse-echo method of normal-incident compressional waves was evaluated for its sensitivity to the worn surface and near surface damage due to wear. Worn surfaces were generated at various oscillation frequency under a given load and amplitude and these surface were in situ monitored using a ultrasonic wave detection system. Analysis of the ultrasonic waves received from the worn surface revealed a close relationship between the surface and near-surface damage and the maximum echo-amplitude of the compressional waves. The ultrasonic technique was successful in assessing the level of severity of the worn surface in real time during the wear process. It is also shown that the wear depth can be easily measured by the calculation of change of the specimen thickness based on the wave speed measured for the specimen medium.

  • PDF

Total Photoyields from CVD Diamond Surfaces and Their Electron Affinity

  • T.Ito;H.Yagi;N.Eimori;A.Hatta;A.Hiraki
    • The Korean Journal of Ceramics
    • /
    • 제3권1호
    • /
    • pp.21-23
    • /
    • 1997
  • Dependences of total photoyields on incident photon energies were measured using synchrotron radiation light for different chemical-vapor-deposited diamond with differently treated surface. Results show that a considerable amount of gap states are presented for as-grown specimens with H-terminated, that negative electron affinity (NEA) is realized for H-plasma-treated specimens, and that sufficient O-treatment to NEA specimens results in positive electron affinity. The observed electron affinity can be explained in terms of differences in strength of the surface dipole layer formed by difference in the electron negativity among C, H and O atoms.

  • PDF