• Title/Summary/Keyword: Incidence angle

Search Result 585, Processing Time 0.026 seconds

A Study on The Surface Roughness Of Metal Workpieces Machined by Ion Sputtering (이온 스파터 가공에 의하 금속표면의 표면거칠기에 관한 연구)

  • 한응교;노병옥;박재민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.747-754
    • /
    • 1990
  • Since Ion sputter machining can perform removing processing in atom or molecule units in vacuum state, it has the merit that high precision processing is possible. In this study, therefore, the effect of incidence ion beam is certified to processing amount and surface roughness when longtimed processing is applied. As a result, processing amount is made almost constant with time and the best processing condition is achieved when the incidencial angle of ion is 55.deg.. In addition, processing time for the good surface roughness is different respectively to the quality of material and longtimed processing has some defect for achieving good surface roughness.

Geometric Assessment and Correction of SPOT5 Imagery

  • Kwoh, Leong Keong;Xiong,, Zhen;Shi, Fusheng
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.286-288
    • /
    • 2003
  • In this paper, we present our implementation of the direct camera model (image to ground) for SPOT5 and use it to assess the geometric accuracy of SPOT5 imagery. Our assessment confirms the location accuracy of SPOT5 imagery (without use of GCPs) is less than 50m. We further introduce a few attitude parameters to refine the camera model with GCPs. The model is applied to two SPOT5 supermode images, one near vertical, incidence angle of 3 degrees, and one far oblique, incidence angle of 27 degrees. The results show that accuracy (rms of check points) of about one pixel (2.5m) can be achieved with about 4 GCPs by using only 3 parameters to correct the yaw, pitch and roll of the satellite.

  • PDF

Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • New & Renewable Energy
    • /
    • v.2 no.1 s.5
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements (천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF

Propulsion Installation Design on Wing-Mounted-Nacelle Type (주익장착방식의 추진기관 장착설계)

  • 진광석;최광윤;공창덕
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.88-94
    • /
    • 1998
  • Installation design methods and results of an aircraft engine on the wing-mounted-nacelle type aircraft has been presented in this paper. The design process starts from design requirements and constraints and covers some major aspects of the engine installation design such as wing-nacelle interference drag, roll clearance, ground clearance, nose gear collapse margin, rotor burst and fuel tank capacity. The method was applied to 100-seat class airplane(K100). Results of the design suggest optimum nacelle location and nacelle installation angle(toe-in, incidence, droop angle) which satisfies in stalled engine performance and size/location of wing dry day.

  • PDF

Fabry-Perot Filter Constructed with Anisotropic Space Layer and Isotropic Mirrors

  • Qi, Hongji;Hou, Yongqiang;Yi, Kui;Shao, Jianda
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.33-37
    • /
    • 2013
  • In this study a new design concept of the Fabry-Perot filter, constructed with an anisotropic space layer and a couple of isotropic mirrors, was proposed based on the Maxwell equations and the characteristic matrix method. The single- and double-cavity Fabry-Perot filters were designed, and their optical properties were investigated with a developed software package. In addition, the dependence of the transmittance and phase shift for two orthogonal polarization states on the column angle of the anisotropic space layer and the incidence angle were discussed. We demonstrated that the polarization state of electromagnetic waves and phase shifts can be modulated by exploiting an anisotropic space layer in a polarization F-P filter. Birefringence of the anisotropic space layer provided a sophisticated phase modulation with varied incidence angles over a broad range, resulting in a wide-angle phase shift. This new concept would be useful for designing optical components with isotropic and anisotropic materials.

Measurement of absorption coefficient using beamforming method (빔형성방법을 이용한 흡음계수 측정법)

  • Ju, Hyung-Jun;Kang, Yeon-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.370.1-370
    • /
    • 2002
  • A method using beamforming has been developed to measure absorption coefncient of oblique incidence. MUSIC(Multiple Signal Classification) method detects the angle of incidence and reflection. And beamforming method separates the incident and reflected wave. And spatial smoothing technique is used to reduce the coherence between the incident and reflected wave. The test material were modeled as a locally reacting surface. Numerical and experiment results are performed to verify the performance of proposed method.

  • PDF

The Study of Aliasing and Incidence Angle Dependence of Doppler Image on Humeral Artery (상완동맥 Doppler 영상의 입사각 의존성과 Aliasing에 관한 연구)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.379-387
    • /
    • 2008
  • Among methods to eliminate aliasing effects, the method of increasing velocity scale gradually eliminated the phenomenon in which the direction of the blood flow appeared in reverse. It was done by increasing the velocity scale while maintaining other parameters in the same state. The method of setting the Doppler angle to $0^{\circ}$ did not show significant changes in the wave pattern of the spectrum according to the angle. In actual ultrasonography tests, more accurate tests are expected to be carried out by applying variations to the velocity scale under the considerations of speed, accuracy, and convenience of the examination. The results showed that blood flow velocity increases exponentially according to the Doppler Angle. When the angle goes over $70^{\circ}$, the velocity value increases to an unmeasurable state. This indicates that in blood flow velocity measurements, the blood flow velocity is very dependent on the Doppler Angle. It also shows that the error increases when the incidence angle to the direction of blood flow exceeds $60^{\circ}$, and when the angle exceeds $70^{\circ}$, the error becomes even greater. In addition, he experiment results showed that an angle below $60^{\circ}$ is appropriate and for blood flow velocity measurements in extremity vessels, the most appropriate Doppler Angle is from $45^{\circ}$ to $60^{\circ}$.

  • PDF

Relationship between Leg Length Discrepancy and Radiological Parameters of Lumbosacrum and Pelvis in Patients with Chronic Low Back Pain (만성 요통 환자의 하지 길이 부전과 요천추부 및 골반의 방사선학적 지표와의 관계)

  • Cho, Yu-Jeong;Chung, Seok-Hee;Song, Mi-Yeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.171-183
    • /
    • 2010
  • Objectives : The biomechanical relationship of leg length discrepancy(LLD), Lumbar lordosis, pelvic variance and degenerative scoliosis is one of the most important parameters when treat musculoskeletal disorders, however the reports are still controversial. The purpose of this study was to compare the relationships between the parameters and bothersomeness in subject with chronic ow back pain. Methods : Sixty female and eight male adults with non specific low back pain over 3 months were recruited. LLD was measured by tape measure method. Lumbar lordosis, lumbosacral angle and related pelvic parameters were measured using simple radiologic films of lumbosacral view. Results : Lumbar lordosis was significantly correlated to the lumbosacral angle, pelvic incidence and difference of the both iliac widths. Pelvic incidence had significant correlation with difference of the both iliac widths. And difference of both iliac widths was related with LLD by radiologic film. There was also significant correlation between the LLD by radiologic film and tape measurement. Visual analogue scale(chronic low back pain) of normal lordosis group was greater than hyperlordosis group. Conclusions : There were close biomechanical relationships between lumbar, pelvis, and lower extremity. But in order to determine the effect of structure on the chronic low back pain, global balance of musculoskeletal structure seems to be worth further researching.