오존산화/응집 혼성공정에 의한 UF 분리막의 막오염 저감에 관한 연구 (A study on mitigation of membrane fouling by ozonation/coagulation in ultrafiltration)

  • 김건엽;김민규;이창하;김형수;김지훈;이경일
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.161-168
    • /
    • 2017
  • Microfiltration (MF) and Ultrafiltration (UF) membrane processes capable of producing highly purified water have been extensively applied as a pretreatment process in the wastewater reuse field with the improvement of membrane properties and resistance, development of operating protocols, and improvement of technologies of backwashing and physicochemical cleaning, and improvement of scale and antifoulants. However, despite of the development of membrane production and process technologies, fouling still remains unresolved. This study confirmed that foulants such as polysaccharides, proteins and humic substances existed in final treated effluent (secondary effluent) by fluorescence excitation emission matrix (FEEM) and fourier transform infrared spectroscopy (FTIR) analysis. In addition, when constructing ozone oxidation and coagulation processes as a hybrid process, the removal efficiency was 5.8%, 6.9%, 5.9%, and 28.2% higher than that of the single process using coagulation in turbidity, color, dissolved organic carbon (DOC), and UV254, respectively. The reversible and irreversible resistances in applying the hybrid process consisting of ozone oxidation and coagulation processes were lower than those in applying ozone oxidation and coagulation processes separately in UF membrane process. Therefore, it is considered possible to apply ozonation/coagulation as a pretreatment process for stable wastewater reuse by and then contributing to the reduction of fouling when calculating the optimal conditions for ozone oxidation and coagulation and then to applying them to membrane processes.

공업용수 생산 정수장의 침전지 조류 부착방지를 위한 황산동 투입 (Using $CuSO_4$ for Preventing Algae Attachment on the Sedimentation Basin of Industrial Water Treatment Plant)

  • 손희종;정종문;김상구;장성호
    • 대한환경공학회지
    • /
    • 제34권11호
    • /
    • pp.780-785
    • /
    • 2012
  • 침전지 구조물에서의 조류 부착현상은 4월말에서부터 10월초까지 나타났고, 침전지 청소 7일 후부터 부착조류가 관찰되었으며, 운전기간이 경과할수록 부착조류의 양은 점진적으로 증가하였다. 부착 조류 종들은 남조류인 Oscillatoria sp.와 Phormidium sp., 규조류 인 Synedra sp., 녹조류인 Mougeotia sp.와 Oedogonium sp.가 관찰되었으며, 부유성 규조류인 Stephanodiscus sp.도 부착조류의 군집에서 자주 관찰되었다. 침전지 월류 조류 종들은 규조류인 Cymbella sp., Navicula sp., Synedra sp.와 Stephanodiscus sp.가 관찰되었고, 녹조류의 경우는 Mougeotia sp.와 Cosmarium sp., 남조류는 Anabaena sp.가 관찰되었다. 황산동의 투입효과를 살펴보기 위해 침전지 트러프의 단위 면적당($cm^2$) 부착조류의 농도를 조사한 결과, 황산동을 투입한 침전지의 경우는 침전지 청소 후 14일과 28일 경과 후에 단위 면적당 부착조류의 농도가 각각 $4{\mu}g/L/cm^2$$19{\mu}g/L/cm^2$로 나타나 조류 부착현상이 매우 더디게 진행된 반면, 황산동을 투입하지 않은 침전지의 경우는 침전지 청소 후 14일과 28일 경과 후의 부착조류 농도가 각각 $59{\mu}g/L/cm^2$$147{\mu}g/L/cm^2$로 나타나 시간의 경과에 따라 다양한 부착조류가 부착하여 성장하였다. 공업용수 처리수의 수질에 미치는 영향을 조사하기 위하여 공업용수도용 배수지의 침전물을 분석한 결과, 적갈색의 미세한 침전물들에서 규조류의 파편들이 검출되었으며, 녹조류와 남조류의 경우는 분해되어 침전물의 유기물 성분으로 존재하면서 산화철과 결합하여 침전물을 형성하였다.

Influence of commercial detergents on UF membrane ageing: Case of drinking water

  • Moulin, P.;Regula, C.;Carretier, E.;Wyart, Y.;Sergent, M.;Gesan-Guiziou, G.;Ferry, D.;Vincent, A.;Boudot, D.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.27-51
    • /
    • 2013
  • During cleaning steps, ultrafiltration membranes are mechanically and chemically stressed. This may result in membrane degradations and failures. In this paper, polysulfone membranes were used to evaluate membrane deteriorations by commercial detergents in static conditions. Ageing of the membrane was simulated by immersing samples in solutions containing commercial detergents with various concentrations, temperatures and times defined by experimental designs. Indeed, an innovative approach in the chemical membranes ageing researches, based on methodological tools, was used in order to achieve significant ageing experiments without using an accelerated ageing protocol. The macroscopic changes were monitored by permeability measurements and mechanical strength tests coupled with a microscopic characterization by ATR-FTIR and HRSEM. The present work details results obtained for three commercial detergents: an alkaline, an acidic and an enzymatic detergent. It was found that the detergents used in the industrial advised conditions (concentration, temperature and time of contact) were not detrimental for membrane properties (permeability and elongation at break) and so for the quality of the produced water. Over the industrial cumulated time of contact, different ageing effects can be observed and compared with the ones induced by NaOCl.

연꽃식물 조직의 표피 특성과 연잎효과 (Epidermal Features of the Nelumbo nucifera Tissues and Lotus Effect)

  • 김인선
    • Applied Microscopy
    • /
    • 제42권2호
    • /
    • pp.95-103
    • /
    • 2012
  • 연잎효과는 연꽃의 잎에서 규명된 현상으로 표피세포에서 기원하는 미세구조에 의해 물방울이 잎 표면이나 내부조직에 침투하지 않고 경사면으로 흘러내리며 표면 위 먼지나 이물질을 함께 떨어지게 한다. 잎 표면을 항상 깨끗한 상태로 유지하는 자기정화 능력인 연잎효과에 대해서는 여러 영역에서 연구되고 다방면으로 응용되고 있으나 구조적인 측면에서 연잎을 생장단계별 또는 표피조직 부위별로 비교 조사한 연구는 거의 없는 실정이다. 이에 본 연구에서는 연잎과 줄기를 대상으로 생장단계별, 부위별 표피조직의 미세 표면구조를 연구하여 연잎효과 표면 특성을 조사하였다. 본 연구에서 조사된 연잎효과는 미세돌기와 왁스결정체가 발달한 잎의 상피조직에서만 나타나고, 왁스결정체만 발달한 하피 및 줄기의 표피조직에서는 확인되지 않았다. 이는 미세돌기의 발달이 연잎효과를 나타내는데 가장 중요한 요인이고, 왁스결정체가 돌기표면 위에 축적되면 연잎효과는 더 증가하는 것으로 밝혀졌다.

셀룰로오스 나노 섬유와 AKD를 활용한 방오 코팅제에 의한 콘크리트 표면의 소수 특성 분석 (An Analysis of Hydrophobic Characteristics of Concrete Surfaces by Antifouling Coating Agent using Cellulose Nonofiber and Alkyl Ketene Dimer)

  • 장낙섭;노치훈;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제11권2호
    • /
    • pp.120-129
    • /
    • 2023
  • 해양구조물은 염분에 의한 손상뿐만 아니라 해양미생물과 부유물질의 착상 등에 의해 추가적인 손상이 발생하게 되며, 이를 억제하기 위하여 선박등의 경우에는 주기적인 도장을 통하여 필요성능을 유지하고 있다. 그러나 콘크리트 또는 강재지지구조는 주기적인 도장이 어렵고 해양환경의 오염위험이 존재하는 것이 사실이다. 본 연구에서는 친수성 셀룰로오스 나노섬유와 AKD를 사용하여 소수성능을 갖는 친환경 재료를 사용하여 방오코팅제를 개발하였다. 균질한 배합을 위해 나노섬유의 함량을 1 %로 고정하고, AKD, 증류수와 폐유리를 디지털 교반기와 호모게나이져로 교반 제작하였다. 제작된 코팅제의 접촉각은 130°이상으로 나타났으며, 15°기울기의 물방울 흐름시험에서도 충분한 성능을 갖추고 있어 자가세척기능을 갖춘 것으로 판단된다. 또한 온도에 따른 점성 특성 분석을 통해 상온에서 시공이 가능한 것을 확인하였으며, 미세구조 분석을 통해 콘크리트표면에 코팅제가 균질하게 도포되는 것을 확인하였다.

침지식 중공사 정밀여과 분리막에서 무기혼합입자 여과에 대한 단계별 공기세정의 영향 (Effect of Step-aeration on Inorganic Particle Mixtures Filtration in a Submerged Hollow Fiber Microfiltration Membrane)

  • 최영근;김현철;노수홍
    • 멤브레인
    • /
    • 제25권3호
    • /
    • pp.256-267
    • /
    • 2015
  • 침지식분리막 오염을 최소화하기 위한 두 가지 공기세정방식을 비교하였다. 연속적인 공기세정과 단계별 공기량을 증가시키는 방식을 연구하였다. 15분의 여과 중에 세정공기의 증가는 5분마다 단계별로 공기량을 증가시켜주었다. 모의 여과 원수에 분말활성탄을 10 g/L 이하 그리고 카올린은 20 g/L 이하로 준비하였으며, 플러스는 80 LMH로 하였다. 단계별 공기세정방식은 연속적인 공기세정 방식보다 분리막 오염억제에 효과적이었다. 추가적으로 주입된 응집제는 분리막 오염저감을 보다 향상시켰다. 연속적인 공기세정의 오염현상은 공경막힘과 분리막 표면에 지속적인 입자의 축적에 기인하였다.

유류오염의 미생물학적 제어 (Bioremedation of petrolium pollution)

  • 이상준;차미선;이근희
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 제3회 부산.경남지부 심포지엄
    • /
    • pp.14-28
    • /
    • 2001
  • As basic study for purpose bioremedation in oil-contaminated environment, Primarily, we isolated biosurfactant producer- strains utilized of oil-agar plate, and measured surface tension and emulsifying activity. We investigated in oil-contaminated soil and sea water. In this laboratory, Pseudomonas sp. EL-012S strain isolated from oil-contaminated soil was able to product novel biosurfactant under the optimal culture condition. Its condition was n-hexadecane 2.0%, NH$_4$NO$_3$0.4%, Na$_2$HPO$_4$0.6%, KH$_2$PO$_4$0.4%, MgSO$_4$.7$H_2O$ 0.02%, CaCl$_2$.2$H_2O$ 0.001%, FeSO.7$H_2O$ 0.001%, initial pH 7.0 and aeration at 3$0^{\circ}C$, respectively. This biosurfactant was produced in both late-exponential and early-stationary phase. The biosurfactant from Pseudomonas sp. EL-012S was composed of carbohydrate, lipid and protein. The purified-biosurfactant was examined two (biosurfactant type I, II) with the silica gel G60 column chromatography and the purified biosurfactant confirmed thin layer chromatography, high performed liquid chromatography and gas chromatography. The biosurfactant type I involved in carbohydrate-lipid-protein characteristics lowered surface tension of water to 27dyne/cm and interfacial tension 4.5dyne/cm aginst to n-hexadecane and the biosurfactant type B involved in carbohydrate lipid characteristics lowered surface tension of water to 30dyne/cm and interfacial tension 8dyne/cm against to n-hexadecane. Specially type I had the properties such as strong emulsifying activity, emulsion stability, pH-stability, thermo-stability, high cleaning activity and forming ability.

  • PDF

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.

머신러닝을 활용한 세라믹 정밀여과 파일럿 플랜트의 파울링 조기 경보 방법 (An early fouling alarm method for a ceramic microfiltration pilot plant using machine learning)

  • 탁도현;김동건;전종민;김수한
    • 상하수도학회지
    • /
    • 제37권5호
    • /
    • pp.271-279
    • /
    • 2023
  • Fouling is an inevitable problem in membrane water treatment plant. It can be measured by trans-membrane pressure (TMP) in the constant flux operation, and chemical cleaning is carried out when TMP reaches a critical value. An early fouilng alarm is defined as warning the critical TMP value appearance in advance. The alarming method was developed using one of machine learning algorithms, decision tree, and applied to a ceramic microfiltration (MF) pilot plant. First, the decision tree model that classifies the normal/abnormal state of the filtration cycle of the ceramic MF pilot plant was developed and it was then used to make the early fouling alarm method. The accuracy of the classification model was up to 96.2% and the time for the early warning was when abnormal cycles occurred three times in a row. The early fouling alram can expect reaching a limit TMP in advance (e.g., 15-174 hours). By adopting TMP increasing rate and backwash efficiency as machine learning variables, the model accuracy and the reliability of the early fouling alarm method were increased, respectively.

정수처리를 위한 정밀여과막 모형플랜트의 장기운전 특성 (Long Term Operation of Microfiltration Membrane Pilot Plant for Drinking Water Treatment)

  • 김충환;이병구;임재림;김성수;이경혁;채선하
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.493-501
    • /
    • 2007
  • The membrane pilot plant has being operated in the Hyeondo pumping station to find the optimal operation technique of Gong-Ju membrane water treatment plant (WTP) which is constructing in $250m^3/d$ scale. The pilot plant was consisted of two trains which can treat $30,000m^3/d$ per train. First train was operated for one year under the condition of flux $1m^3/m^2{\cdot}d$ while the effects of flux variation and addition of powdered activated carbon(PAC) were evaluated in second train. The turbidity of membrane product water of first train which is operated on Flux $1m^3/m^2{\cdot}d$ was always below 0.05 NTU regardless of raw water turbidity. And also, the trance-membrane pressure(TMP) was maintained at $0.3{\sim}0.5kgf/cm^2$ for about 9 months and increased rapidly to $1.8kgf/cm^2$ which is maximum operating TMP. However, TMP was rapidly increased to $1.8kgf/cm^2$ within 2 months as flux was increased from 1 to $2m^3/m^2{\cdot}d$, especially, within 10 days under high turbidity(30~50NTU). This reault means that if Gongju membrane WTP is operated in flux $1m^3/m^2{\cdot}d$, chemical cleaning period can be maintained over 6 months. Only 10% of dissolved organic carbon (DOC) was removed in membrane process while the removal efficiencies of manganese and iron were 60% and 77% respectively. However, because only solid manganese and iron were removed in membrane process, an additional process for treating soluble manganese is required if souble manganese is high in raw water. 70% of 70ng/L 2-MIB which is causing taste & odor was removed in powdered activated carbon (PAC) tank with 50mg/L PAC which is design concentration of Gongju WTP. In addition, TMP was reduced with addition of 50mg/L PAC regardless of flux. Because TMP was not influenced even if 100mg/L PAC was added, the high taste and odor problem can be controled by additional injection of PAC.