반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화 (The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process)

  • 이상호;이승호;김규채;권태영;박진구;배소익;이건호;김인정
    • 반도체디스플레이기술학회지
    • /
    • 제4권4호
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

역삼투막의 전처리를 위한 정밀여과막의 평가 (Evaluation of Microfiltration Membrane as Prefilter for Reverse Osmosis membrane)

  • 홍성호;오석환;전재홍
    • 청정기술
    • /
    • 제7권3호
    • /
    • pp.179-185
    • /
    • 2001
  • 각종 전처리 필터로 사용되는 정밀여과막은 국내의 경우 대부분 수입에 의존하고 있다. 몇몇 회사에서 개발을 시도하고 있지만, 막에 대한 특성 파악이나 공극제어등과 같은 문제를 해결하는데 많은 어려움이 있다. 따라서 본 연구에서는 A 사에서 개발한 정밀여과막을 이용하여 한강원수와 시수에 대하여 RO 유입전 전처리 필터로서의 적합성을 판단하고자 본 연구를 수행하였다. 한강원수는 총 2회에 걸쳐서 실험을 실시하였다. 적정 공급수 압력은 0.2~0.4 기압이며 여과수의 탁도는 0.4 NTU를 나타냈다. 플럭스는 $6,000{\sim}9,000L/m^2/hr$ 였다. 시수의 경우 회수율을 90%로 운전시 안정된 플럭스와 탁도를 나타내었다. 화학세정 후 TMP의 증가율은 감소를 하였으며, 탁도는 0.4 NTU에서 0.1 NTU로 개선되었다.

  • PDF

수질배출부과금제도 개선 방안 연구 (The Effect of Industrial Waste Water Effluent Charge Reform)

  • 민동기
    • 자원ㆍ환경경제연구
    • /
    • 제18권4호
    • /
    • pp.767-785
    • /
    • 2009
  • 본 연구에서는 수질배출부과금제도의 부과체계를 분석하고 개선 방안을 연구하였다. 수질배출부과금제도는 환경오염 원인자에게 처리비용을 부담시켜 환경자원을 효율적으로 사용하도록 하는 경제적 유인 목적을 가지고 있으나 현행 수질배출부과금제도는 행정 규제적 성격이 강하다. 즉, 배출허용기준을 설정하여 이를 위반한 배출업소에 대하여 사업장 규모, 지역, 위반 횟수, 오염물질별 초과율을 고려한 누증적 부과계수를 적용하여 실제 환경오염 비용을 훨씬 초과하는 형벌적 성격의 부과금을 부과하고 있다. 그러나 과도한 부과금 부과로 배출부과금 징수율은 환경관련 부과금 중 가장 낮은 수준이다. 따라서 본 연구에서는 규제적 성격의 부과체계를 개편하여 경제적 유인제도로 수질배출부과금제도를 개편하는 부과체계 개편안을 연구하였으며 이에 따른 부과액 및 징수액 변화 효과를 추정하였다. 추정 결과를 보면 현행 부과금 부과액은 오염물질 처리단가의 약 4배 이상을 부과하고 있어 환경자원의 비효율적 배분을 초래하고 있음을 보여준다. 아울러 과도한 부과금 부과체계를 개선하는 경우에는 징수율도 제고되어 수질배출부과금제도의 기능을 회복할 수 있음을 보여준다.

  • PDF

저융점 폴리에스테르 복합사의 저온 염색성 (Dyeability of Low-melting Hybrid Polyester at Low Temperature)

  • 황지현;김창남;마진숙;오해선;윤남식
    • 한국염색가공학회지
    • /
    • 제24권2호
    • /
    • pp.113-120
    • /
    • 2012
  • Jacquard floor covering could be prepared from low-melting/regular sheath-core hybrid polyester, where the fiber is dyed in yarn state. With regard that the expected high shrinkage of the hybrid polyester in water makes problems in yarn dyeing, low-temperature dyeing properties of the hybrid polyester were studied. The rate of shrinkage of low-melting hybrid polyester exceeds 9% in hot water above $90^{\circ}C$, at such condition, cheese yarn dyeing is very difficult. Although disperse dyes exhaust in a relatively high speed on low-melting hybrid polyester, diffusion of these dyes to the core regular polyester was extremely slow under $90^{\circ}C$. Foron Blue E-BL 150, an anthraquinone E-type disperse dye, showed appreciable diffusion after 48hrs dyeing at $90^{\circ}C$. The fastness to rubbing and drycleaning were improved by one grade after reduction cleaning.

DEVELOPMENT OF A STEAM GENERATOR LANCING SYSTEM

  • Jeong Woo-Tae;Kim Seok-Tae;Hong Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.391-398
    • /
    • 2006
  • It is recommended to clean steam generators of nuclear power plants during plant outages. Under normal operations, sludge is created and constantly accumulates in the steam generators. The constituents of this sludge are different depending on each power plant characteristics. The sludge of the Kori Unit 1 steam generator, far example, was found to be composed of 93% ferrous oxide, 3% carbon and 1% of silica oxide and nickel oxide each. The research to develop a lancing system that would remove sludge deposits from the tubesheet of a steam generator was started in 1998 by the Korea Electric Power Research Institute (KEPRI) of the Korea Electric Power Corporation (KEPCO). The first commercial domestic lancing system in Korea, the $KALANS^(R)-I$ Lancing System, was completed in 2000 for Kori Unit 1 for cleaning the tubesheet of its Westinghouse Delta-60 steam generator. Thereafter, the success of the development and site implementation of the $KALANS^(R)-I$ lancing system for YGN Units 1&2 and Ulchin Units 3&4 was also realized in 2004 for sludge removal at those sites. The upper bundle cleaning system for Westinghouse model F steam generators is now under development.

Removal of iron scale from feed-water in thermal power plant by magnetic separation - Introduction to chemical cleaning line -

  • Yamamoto, Junya;Mori, Tatsuya;Hiramatsu, Mami;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Namba, Seitoku;Sekine, Tomokazu;Mishima, Fumihito;Nishijim, Sigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권2호
    • /
    • pp.6-10
    • /
    • 2018
  • Removal of iron oxide scale from feed-water in thermal power plant can improve power generation efficiency. We have proposed a novel scale removal system utilizing High Gradient Magnetic Separation (HGMS). This system can be applied to high temperature and pressure area. We have conducted the lab-scale model experiments using ${\varphi}50mm$ filters and it demonstrated high removal efficiency in HGMS, but scale-up of the system is required toward practical use. In this study, we conducted a large scale mock-up HGMS experiment. We used the superconducting solenoidal magnet with ${\varphi}400mm$ bore and demonstrated that our HGMS system can achieve sufficient scale removal capacity that is required to introduce into both off-line and on-line system.

Effect of coagulation conditions on ultrafiltration for wastewater effluent

  • Maeng, Sung Kyu;Timmes, Thomas C.;Kim, Hyun-Chul
    • Membrane and Water Treatment
    • /
    • 제8권2호
    • /
    • pp.185-199
    • /
    • 2017
  • Low-pressure membrane filtration is increasingly used for tertiary treatment of wastewater effluent organic matter (EfOM), mainly comprising organic base/neutral compounds. In-line coagulation with underdosing, charge neutralization, and sweep floc conditions prior to ultrafiltration (UF) was studied to determine removals of the EfOM components and consequent reduction of fouling using polyethersulfone membranes. Coagulation and UF substantially reduced fouling for all coagulation conditions while removing from 7 to 38% of EfOM organic acids. From 7 to 16% of EfOM organic base/neutrals were removed at neutral pH but there was no significant removal for slightly acid coagulation conditions even though fouling was substantially reduced. Sweep floc produced the lowest resistance to filtration but may be inappropriate for in-line use due to the large added volume of solids. Charge-neutralization resulted in poor recovery of the initial flux with hydraulic cleaning. Under-dosing paralleled sweep floc in reducing hydraulic resistance to filtration (for sub-critical flux) and the initial flux was also easily recovered with hydraulic cleaning. Hydrophobic and hydrophilic base/neutrals were identified on the fouled membranes but as previously reported the extent of fouling was not correlated with accumulation of organic base/neutrals.

RTOS를 이용한 실시간 복합비례방식 자동 염소투입기 시스템 설계 (Design of Real Time Complex Proportion Method Automatic Chlorine Input System using RTOS)

  • 김시환;인치호
    • 전기전자학회논문지
    • /
    • 제6권2호
    • /
    • pp.146-151
    • /
    • 2002
  • 본 논문은 RTOS를 이용하여 정수장의 염소투입을 실시간으로 제어할 수 있는 시스템을 제안하였다. 기존 정수장의 염소투입방식은 유량방법을 이용하여 제어하였으며 계절이나 시간 또는 물의 사용량과 같은 외부환경에 대한 적절한 제어가 불가능 하였다. 따라서 본 논문에서는 유량방법과 잔류염소방식의 2가지 방법으로 시스템을 설계하고, RTOS의 각 태스크는 외부 환경 변화를 실시간으로 체크하여 염소농도 조절에 이용되는 연산의 보정값을 조절할 수 있도록 프로그램 하였다. 제안한 시스템을 2곳의 정수장에 설치하고 설정을 1.2ppm으로 하여 실험한 결과 1.21ppm의 평균값을 유지하였으며 최대, 최소의 편차 또한 0.3ppm으로 기존 정수장보다 우수한 성능을 나타내었다.

  • PDF

분산염료/산성염료에 의한 PTT(polytrimethylene terephthalate)/견 교직물의 염색에 관한 연구 (A Study on the Dyeing of PTT(polytrimethylene terephthalate)/Silk Mixture Fabrics with Disperse Dyes/Acid Dyes)

  • 성우경
    • 한국의류산업학회지
    • /
    • 제12권1호
    • /
    • pp.94-102
    • /
    • 2010
  • The dyeing of poly(trimethylene terephthalate)(PTT)/silk mixture fabrics can be accomplished by a two bath dyeing method with separate application of the disperse dyes on the PTT, reduction cleaning of the stained silk and then dyeing the silk with the acid dyes, or by one bath dyeing method with mixed dye ranges, possibly followed by a cleaning treatment. The two bath dyeing method has the advantage of better results with respect to dry cleaning fastness properties thanks to the possibility of an intermediate reduction clear. On the other hand, as compared with the two bath dyeing method, one bath dyeing method with a mixed dye range permits rapid and more reproducible dyeing, without the risk of great difference with respect to the shade of the strike on both substrates as well as savings of time, energy and water usage. This study was carried out to investigate dyeing characteristics of PTT/silk mixture fabrics with disperse dyes/acid dyes by one bath dyeing method in comparison with two bath dyeing method in the interests for rationalization of the dyeing process.

섬유상 여과필터의 고온 내구성 향상을 위한 테프론 코팅 연구 (Teflon coating of fabric filters for enhancement of high temperature durability)

  • 김은주;박영구
    • 한국응용과학기술학회지
    • /
    • 제28권2호
    • /
    • pp.232-239
    • /
    • 2011
  • Fabric fibrous filter has been used in various industrial applications owing to the low cost and wide generality. However, the basic properties of fabric materials often limit the practical utilization including hot gas cleaning. This study attempts to find new coatings of porous fibrous filter media in order to overcome its insufficient thermal resistance and durability. Teflon was one of the plausible chemicals to supplement the vulnerability against frequent external thermal impacts. A foaming agent composed of Teflon and some organic additives was tentatively coated on the glass fiber mat. The present test Teflon foam coated filter was fount to be useful for hot gas cleaning, up to $250^{\circ}C$-$300^{\circ}C$. Close examination using XPS(X-ray Photoelectron Spectroscopy) and Contact angle proved the binding interactions between carbon and fluorine, which implies coating stability. The PTFE/Glass foam coated filter consisted of more than 95% (C-F)n bond, and showed super-hydrophobic with good-oleophobic characteristics. The contact angle of liquid droplets on the filter surface enabled to find the filter wet-ability against liquid water or oil.