• 제목/요약/키워드: In-water cleaning

검색결과 652건 처리시간 0.024초

Controllable Etching of 2-Dimentional Hexagonal Boron Nitride by Using Oxygen Capacitively Coupled Plasma

  • Qu, Deshun;Yoo, Won Jong
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.170-170
    • /
    • 2013
  • We present a novel etching technique for 2-dimentional (2-D) hexagonal boron nitride (h-BN) by using capacitively coupled plasma (CCP) of oxygen combined with a post-treatment by de-ionized (DI) water. Oxygen CCP etching process for h-BN has been systematically studied. It is found that a passivation layer was generated to obstruct further etching while it can be easily and radically removed by DI water. An essential cleaning effect also has been observed in the etching process, organic residues are successfully removed and the surface roughness has much decreased. Considering h-BN is the most important 2-D dielectric material and its potential application for graphene to silicon-based electronic devices, such an etching method can be widely used to control the 2-D h-BN thickness and improve the surface quality.

  • PDF

탈이온수의 압력과 정제된 $N_2$가스가 ILD-CMP 공정에 미치는 영향 (Influence of DI Water Pressure and Purified $N_2$Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process)

  • 김상용;이우선;서용진;김창일;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.812-816
    • /
    • 2000
  • It is very important to understand the correlation of between inter dielectric(ILD) CMP process and various facility factors supplied to equipment to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD-CMP process was studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyze various facilities supplied at supply system. With facility shortage of D.I water(DIW) pressure, we introduced an adding purified $N_2$(P$N_2$)gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and P$N_2$gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and P$N_2$gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

Enhanced Self-Cleaning Performance of Ag-F-Codoped TiO2/SiO2 Thin Films

  • Kim, Byeong-Min;Kim, Jung-Sik
    • 한국재료학회지
    • /
    • 제28권11호
    • /
    • pp.620-626
    • /
    • 2018
  • Highly self-cleaning thin films of $TiO_2-SiO_2$ co-doped with Ag and F are prepared by the sol-gel method. The asprepared thin films consist of bottom $SiO_2$ and top $TiO_2$ layers which are modified by doping with F, Ag and F-Ag elements. XRD analysis confirms that the prepared thin film is a crystalline anatase phase. UV-vis spectra show that the light absorption of $Ag-F-TiO_2/SiO_2$ thin films is tuned in the visible region. The self-cleaning properties of the prepared films are evaluated by a water contact angle measurement under UV light irradiation. The photocatalytic performances of the thin films are studied using methylene blue dye under both UV and visible light irradiation. The $Ag-F-TiO_2/SiO_2$ thin films exhibit higher photocatalytic activity under both UV and visible light compared with other samples of pure $TiO_2$, Ag-doped $TiO_2$, and F-doped $TiO_2$ films.

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • ;;김영민;오승진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

분뇨수거량 평가방법 연구 : 서울시를 중심으로 (Prediction of Sludge's Volume Collected from Septic Tank Cleaning in Seoul)

  • 유기영;조인성
    • 유기물자원화
    • /
    • 제15권4호
    • /
    • pp.138-146
    • /
    • 2007
  • 서울시에는 아직도 생활하수와 빗물이 함께 흘러가는 합류식 하수관거지역이 많다. 이들 지역의 모든 건물들은 화장실 세정수로부터 고체상 물질을 분리해서 저장하는 정화조가 설치되어 있다. 정화조는 연 1회 이상 청소를 해야 하며 이 과정에서 분뇨가 수거된다. 수거분뇨는 처리시설이 필요로 하며, 과부족이 없는 처리시설을 확보하기 위해서는 장래에 발생할 분뇨수거량을 예측해야 한다. 본 연구에서는 그 분뇨수거량의 예측방법을 검토하였다. 여러 가지 예측인자 중 건물연면적이 가장 신뢰할 수 있었고, 수거분뇨는 처리 시설이 필요로 하며, 과부족이 없는 처리시설을 확보하기 위해서는 장래에 발생할 분뇨수거량을 예측해야 한다. 본 연구에서는 그 분뇨수거량의 예측방법을 검토하였다. 여러 가지 예측인자 중 건물연면적이 가장 신뢰할 수 있었고, 분뇨수거량이 꾸준하게 증가해서 2020년 서울시에서는 1일 13,149kL이 발생할 것으로 평가되었다. BOD의 변화도 예측이 가능하였다.

  • PDF

초음파 핵연료 세정장비의 시스템 구성과 제거된 크러드의 정량적 무게 측정법 (System Configuration of Ultrasonic Nuclear Fuel Cleaner and Quantitative Weight Measurement of Removed CRUD)

  • 신중철;이학윤;성운학;주영종;김용찬;한욱진
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2024
  • Crud is a corrosion deposit that forms in equipments and piping of nuclear reactor's primary systems. When crud circulates through the reactor's primary system coolant and adheres to the surface of the nuclear fuel cladding tube, it can lead to the Axial Offset Anomaly (AOA) phenomenon. This occurrence is known to potentially reduce the output of a nuclear power plant or to necessitate an early shutdown. Consequently, worldwide nuclear power plants have employed ultrasonic cleaning methods since 2000 to mitigate crud deposition, ensuring stable operation and economic efficiency. This paper details the system configuration of ultrasonic nuclear fuel cleaning equipment, outlining the function of each component. The objective is to contribute to the local domestic production of ultrasonic nuclear fuel cleaning equipment. Additionally, the paper introduces a method for accurately measuring the weight of removed crud, a crucial factor in assessing cleaning effectiveness and providing input data for the BOA code used in core safety evaluations. Accurate measurement of highly radioactive filters containing crud is essential, and weighing them underwater is a common practice. However, the buoyancy effect during underwater weighing may lead to an overestimation of the collected crud's weight. To address this issue, the paper proposes a formula correcting for buoyancy errors, enhancing measurement accuracy. This improved weight measurement method, accounting for buoyancy effects in water, is expected to facilitate the quantitative assessment of filter weights generated during chemical decontamination and system operations in nuclear power plants.

Study of the used deuterium absorption material disposal

  • Kim, Dong-Gyung;Kim, Myung-Chul;Lee, Bum-Sig;Lee, Sang-Gu
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.64-72
    • /
    • 2004
  • The dryer (ten per unit) are operating to remove tritium in PHWR(Pressurized Heavy Water Reactor). There are coming out heavy water adsorbent from operating the dryer (95 drums for ten year per unit) The amount of radioactivity of heavy water adsorbent almost exceed ninety times more than disposal limit-in-itself showed by The Ministry of Science and Technology. It has to be disposed whole radioactive waste products, however there are problems of increase at the expense of their permanent disposal. In this research, We have studied how to remove kinds of nuclear materials and amount of tritium with in heavy water adsorbent. As the result we could develop disposal equipment and apply it. D20 adsorbent have to contain below Gamma nuclide O.3Bq/g and tritium 100Bq/g "The Regulation for disposal of the radioactivity wastes" showed by The Ministry of Science and Technology. There fore. So as to remove amount of tritium and kinds of nuclear materials (DTO) we needed a equipment. Also we have studied how to remove effectively radioactivity with in Adsorbent. As cleaning heavy water adsorbent and drying on each condition (temperature for drying and hours for cleaning). Because there is something to return heavy water adsorbent by removing impurities within adsorbent when it is dried o high temperature. After operating, we have been applying this research to the way to dispose heavy water adsorbent. Through this we could reduce solid waste products and the expense of permanent disposal of radioactive waste products and also we could contribute nuclear power plant run safely. According to the result we could keep the best condition of radiation safety super vision and we could help people believe in safety with Radioactivity wastes control for harmony with Environment.

  • PDF

소형장치에 의한 잉어의 성장실험 (REARING EXPERIMENT OF COMMON CARP IN SMALL AQUARIUM)

  • 김인배;조재윤
    • 한국수산과학회지
    • /
    • 제10권4호
    • /
    • pp.275-279
    • /
    • 1977
  • 전성장실험기간을 통하여 잉어의 먹이 섭취와 성장 및 사료효율은 스트레이너의 지소회수, 오탁된 사육수의 교환정도, 먹이의 분할공급의 회수, 적량내의 먹이 공급 및 용존산소량에 직접적이고 직각적인 반응을 나타내었다. 그러나 지소나, 물 교환을 위한 취급에는 별로 영향을 받지 않는 것으로 보였다. 특히 해로운 점은 식욕이 왕성하지 못할 때 먹이를 주는 일과 일시에 과량의 먹이는 주는 것이었다. 특히 직각적으로 삼킬 수 있는 량을 주면 물에 녹아나는 것이 거의 없고, 먹이를 준 후에도 물이 투명하지만, 그 이상의 먹이를 주면 식욕이 왕성할 때는 입속에 여분의 먹이를 머금고 삼킬 노력을 함으로써 녹아서 물에 흩어져 나오는 량이 많고, 먹이를 준 후 물이 혼탁해 진다. 그리하여, 여과조를 포함한 사육수질을 악화시키고, 성장이 불량해지고, 또 사료의 효율을 심하게 저하시킨다.

  • PDF

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

드라이클리닝 시스템에서의 세척성과 재오염성 -계면활성제의 종류와 혼합이 미치는 영향- (Detergency and soil Redeposition in a Drycleaning System -The Effect of Surfactant Type and Their Mixture-)

  • 김주연;박정희
    • 한국의류학회지
    • /
    • 제23권7호
    • /
    • pp.1030-1039
    • /
    • 1999
  • The effect of surfactant mixture 9on detergency and soil redeposition in a dry-cleaning system was investigated employing Aerosol OT as an anionic surfactant and Span 80 as a nonionic surfactant. The effect of charge system on soil deposition was also investigated in order to determine the optimum condition at which soil redeposition is minimum,. Soil deposition instead of soil redeposition on cotton, polyester and wool fabrics was measured employing petroleum solvent and perchloroethylene as organic solvents. The results were as follows. 1. Surface tension or interfacial tension was not changed by the addition of any surfactant or surfactant mixtures. In petroleum solvent however interfacial tension between solrent and water decreased when surfactants were added and increased when surfactants were mixed,. 2. The maximum amount of water solubilization increased as the mole fraction of Aerosol OT increased and more water was solubilized in petroleum solvent than in perchloroethylene. 3. The detergency of cotton was greater and the soil deposition rate was lower in Span 80 solution than in Aerosol OT solution. The soil deposition on cotton fabric decreased when water was solubilized in Aersol OT solution 4. The detergency and soil deposition rate of polyester fabric did not change by the surfactant type of the addition of surfactant mixture and soil deposition rate increased bywater solubilization. 5. Soil deposition on wool fabric was very high when Arosol OT was employed in perchloroethylene and the soil deposition did not change greatly by water solubilization.

  • PDF