• Title/Summary/Keyword: In-water cleaning

Search Result 652, Processing Time 0.024 seconds

Removal of chromium from tannery wastewater by electrosorption on carbon prepared from peach stones: effect of applied potential

  • Ziati, Mounir;Khemmari, Fariza;Kecir, Mohamed;Hazourli, Sabir
    • Carbon letters
    • /
    • v.21
    • /
    • pp.81-85
    • /
    • 2017
  • The objective of this study is the removal of chromium from tannery wastewater by electrosorption on carbon prepared from lignocellulosic natural residue "peach stones' thermally treated. The followed steps for obtaining coal in chronological order were: cleaning, drying, crushing and finally its carbonization at $900^{\circ}C$. The characterization of the carbon material resulted in properties comparable to those of many coals industrially manufactured. The study of the dynamic adsorption of chromium on the obtained material resulted in a low removal rate (33.7%) without applied potential. The application of negative potentials of -0.7 V and -1.4 increases the adsorption of chromium up to 90% and 96% respectively. Whereas a positive potential of +1.4V allows desorption of the contaminant of 138%.

Disinfection Effects of Electrolyzed Water on Strawberry and Quality Changes during Storage (전기분해수 처리에 의한 딸기의 살균 효과 및 저장 중 품질변화)

  • Jeong Jin-Woong;Kim Jong-Hoon;Kwon Ki-Hyun;Park Kee-Jai
    • Food Science and Preservation
    • /
    • v.13 no.3
    • /
    • pp.316-321
    • /
    • 2006
  • Disinfection of electrolyzed water (EW) on strawberry by immersion washing and quality changes during storage at $5^{\circ}\C$ was compared with one immersed in chlorine water and not treated. Total count of strawberry washed with EW by immersion in 10 volumes of EW for 20 min was decreased to about 2 log cycle compared to the untreated And rate of microbial growth during storage was lower than ethers. Decaying ratio in strawberry treated with electrolyzed low-alkalinewater (EW-2) showed lower as of 10% level after 5 days of storage compared) to the untreated and the treated with chlorine water (CW). Hardness in the treatment of EW was not changed significantly until 3 days of storage, after then rather increased. Change in surface color of strawberries was observed; L value in the CW treated and the untreated increased whereas it decreased in the treatment of EW. And color difference(${\Delta}E$) during storage was observed the lowest in the untreated until 3 days of storage. The initial value of residual chlorine in the treatment of EW was at the level of $0.04{\sim}0.06ppm$, and $1{\sim}3$ days later showed almost the equal value to level of $0.02{\sim}0.03ppm$ in all treatments. Sensory characteristic during storage was preferable on strawberry washed with EW (EW-1 and EW-2) to the other treatments.

Natural Dyeing of Fabrics with Guava (Psidium guajava L.) Leaf Extract II - Dyeability and Functional Property of Cotton Fabrics - (구아바 잎 추출액을 이용한 직물의 천연염색(II) - 면직물의 염색성과 기능성 -)

  • Han, Mi-Ran;Lee, Jeong-Sook
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.320-330
    • /
    • 2012
  • The natural dyeing of cotton fabrics with guava leaf extract was investigated. The temperature and time of dyeing are $40^{\circ}C$ and $90^{\circ}C$ for eighty minutes, respectively. In addition, the dyebath has been set at pH 5. Sn pre-mordanted fabrics showed the highest K/S value. Regardless of dyeing temperature, K/S values were high when Al, Cu, Fe-mordanted fabrics were dyed in post-mordanting and Sn-mordanted fabrics were dyed in pre-mordanting. The K/S value of dyeing fabrics could be increased with repetitive dyeing and mordanting. Compared to untreated dyed fabrics, the K/ S values of fabrics which had been treated with soybean milk, chitosan and gall nut tannin were increased. The changed surface colors of fabrics that were treated with soybean milk, chitosan and gall nut tannin were Y, YR and achromatic colors. Fabrics dyed with alkaline water extract showed reddish color. Sn-mordanted fabrics dyed with acidic water extract showed vivid yellowish color, and Cu-mordanted fabrics dyed with ethanol extract showed yellowish green color. In case of Sn-mordanted fabrics, the washing fastness was level 4. The dry cleaning fastness also showed very excellent result with level 4-5. The rubbing fastness was better in dry rubbing than in wet rubbing of the fabrics. For the light fastness, all dyed fabrics showed low fastness. For antibacterial activity, the powder of guava leaf extract and the dyed fabrics with guava leaf extract showed 99.9% of high antibacterial activity. All dyed fabrics showed higher deodorization and UV protection rate than control fabric.

Hydrophillic and Hydrophobic Properties of Sol-Gel Processed Sillica Coating Layers

  • Kim, Eun-Kyeong;Lee, Chul-Sung;Hwang, Tae-Jin;Kim, Sang-Sub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.505-505
    • /
    • 2011
  • The control of wettability of thin films is of great importance and its success surely brings us huge applications such as self-cleaning, antifogging and bio-passive treatments. Usually, the control is accomplished by modifying either surface energy or surface topography of films. In general, hydrophobic surface can be produced by coating low surface energy materials such as fluoropolymer or by increasing surface roughness. In contrast, to enhance the hydrophillicity of solid surfaces, high surface energy and smoothness are required. Silica (SiO2) is environmentally safe, harmless to human body and excellently inert to most chemicals. Also its chemical composition is made up of the most abundant elements on the earth's crest, which means that SiO2 is inherently economical in synthesis. Moreover, modification in chemistry of SiO2 into various inorganic-organic hybrid materials and synthesis of films are easily undertaken with the sol-gel process. The contact angle of water on a flat silica surface on which the Young's equation operates shows ~50o. This is a slightly hydrophilic surface. Many attempts have been made to enhance hydrophilicity of silica surfaces. In recent years, superhydrophilic and antireflective coatings of silica were fabricated from silica nanoparticles and polyelectrolytes via a layer-by-layer assembly and postcalcination treatment. This coating layer has a high transmittance value of 97.1% and a short water spread time to flat of <0.5 s, indicating that both antireflective and superhydrophilic functions were realized on the silica surfaces. In this study, we assessed hydrophillicity and hydrophobicity of silica coating layers that were synthesized using the sol-gel process. Systematic changes of processing parameters greatly influence their surface properties.

  • PDF

A Study on the Risk Assessment and Improvement Methods Based on Hydrogen Explosion Accidents of a Power Plant and Water Electrolysis System (발전소 및 수전해 시스템의 수소 폭발 사고 사례 기반 위험성 평가 및 개선 방안 연구)

  • MIN JAE JEON;DAE JIN JANG;MIN CHUL LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.66-74
    • /
    • 2024
  • This study addresses the escalating issue of worldwide hydrogen gas accidents, which has seen a significant increase in occurrences. To comprehensively evaluate the risks associated with hydrogen, a two approach was employed in this study. Firstly, a qualitative risk assessment was conducted using the bow-tie method. Secondly, a quantitative consequence analysis was carried out utilizing the areal locations of hazardous atmospheres (ALOHA) model. The study applied this method to two incidents, the hydrogen explosion accident occurred at the Muskingum River power plant in Ohio, USA, 2007 and the hydrogen storage tank explosion accident occurred at the K Technopark water electrolysis system in Korea, 2019. The results of the risk assessments revealed critical issues such as deterioration of gas pipe, human errors in incident response and the omission of important gas cleaning facility. By analyzing the cause of accidents and assessing risks quantitatively, the effective accident response plans are proposed and the effectiveness is evaluated by comparing the effective distance obtained by ALOHA simulation. Notably, the implementation of these measures led to a significant 54.5% reduction in the risk degree of potential explosions compared to the existing risk levels.

Comparison of Bonding Strength by Cleaning Method of Pediatric Zirconia Crown Contaminated with Saliva or Blood (타액 및 혈액오염 시 유치 지르코니아 기성관 내면의 세척 방법에 따른 결합강도의 비교)

  • Kim, Jaeyong;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.185-194
    • /
    • 2018
  • The objective of this study was to compare the shear bonding strength of zirconia after cleaning the crown contaminated by saliva or blood and determine the effect of thermocycling. 180 specimens were embedded in acrylic resin. 20 Specimens in the positive control group were bonded with resin cement without contamination. 20 Specimens in the negative control group were washed with water for 20 seconds and then dried for 10 seconds. 120 Specimens contaminated by saliva or blood were cleaned by using three cleaning methods: 37% phosphoric acid gel, commercial cleanse, and 2.5% NaOCl. All samples were bonded with resin cement and divided into two subgroups: One was not aged, and the other was tested with 30,000 thermocycling. In both groups contamination by saliva and blood, no statistically significant difference was not found in control, groups cleansed by commercial cleanser and 2.5% NaOCl. When the groups cleansed with water and 37% phosphate gel were compared with the control, significantly low shear bond strength was shown. Thermocycling group showed statistically significantly low shear bond stress compared to the groups without thermocycling. When zirconia was contaminated by saliva or blood, its original shear bond strength could be obtained if it was cleaned with commercial cleanser or 2.5% NaOCl.

Characteristics of Permeation and Fouling of UF/MF Hollow Fiber Membranes for Drinking Water Treatment (정수처리 적용을 위한 UF/MF 중공사막의 투과성능과 오염현상)

  • 이주형;김정학;이용택
    • Membrane Journal
    • /
    • v.10 no.2
    • /
    • pp.75-82
    • /
    • 2000
  • This study, which was tarried out to investigate the characteristics of permeation rates and fouling phenomena in drinking-water treating processes with MF membrane, showed that pressure drop was dependent on the length of membrane module and operating pressure; the pressure drop increased with the length of membrane module and operating pressure, operation at a relatively low pressure(0.5kg/$cm^2$) is better than that at a relatively (2.0kg/$cm^2$), since high operating pressure accelerates the clogging. In case of out-in permeation type, almost same flux was obtained after a certain operating time regardless of membrane length and operating pressure. In order to understand, the microbial fouling, chemical cleaning was carried out to the forced contaminated hollow-fiber membrane with chemicals($H_2O_2$, NaOCl, and NaOH). Chemical cleanings with $H_2O_2$and NaOCl, which are oxidizing agents, are better for sterilizing and desorbing the microbes than those with NaOH.

  • PDF

Effects of Post-Harvest Bulk Management System Using Rice Processing Complex on Labor Saving and Quality of Barley (보리 산물처리에 의한 품질변화와 생력효과)

  • 이춘우;윤의병;구본철;백성범;손영구;서세정;남중현;김완석
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47 no.6
    • /
    • pp.475-478
    • /
    • 2002
  • Post-harvest treatment for barley production requires many steps including drying, cleaning, and packing, and these steps be needed many labor input. Rice processing complex (RPC) is useful for post harvest management system in rice production. However, it is rare to be used for barley production. This study was conducted to explore the variations of quality and labor saving between conventional method and bulk-management system in post-harvest using RPC. The sorting rate was not different between manual method and bulk management. The hardness of non-polished grain was ranged 10,175-10,329 g/$3.14mm^2$, and that for non-polished grain was higher than that for polished grain, but there was not different between drying method. There was not be showed the hunter's value such as L, a and b according to drying method. Cooking characters such as water absorption ratio, swelling ratio, and water soluble extracts by circulated or continued dryer was higher than manual drying using solar heat. Labor input per ha for each cultivation process in bulk-management of barley using rice processing complex was 21 hours, compared to 46 hr/ha in the conventional method, labor input was greatly saved by up to 54.3% in the post-harvest bulk management system.

Detailed Design for 25bar-class Biogas Compression Supplying System (25BAR급 바이오가스 고압 압축공급시스템 상세설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yun, Eun-Young;Lee, Jung-Bin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173.1-173.1
    • /
    • 2011
  • The high fuel flexibility of gas turbine power system has boosted their use in a wide variety of applications. Recently, the demand for biogas generated from the digestion of organic wastes and sewage waste water as a fuel for gas turbines has increased. We investigated the performance of high pressure biogas compression system and operating conditions for supplying biogas. The total flow per minute of biogas from food waste water digestion tank is $54Nm^3$. The main type of biogas compression system is the reciprocating system and screw type system. The target of biogas mechanical data is the as belows; inlet pressure 0.045bar, supplying biogas temperature is $30{\sim}60^{\circ}C$, and final pressure is above the 25 bar. Also, inlet conditions of biogas consist of CH4 48.5%~83%, $H_2S$ Max. 500ppm, $NH_3$ Max. 1,500ppm and Siloxane 2.7~4.6ppm. The boosting Blower system raises a pressure from 0.045bar to 1bar before main compressor. The main system lay out of reciprocating consisits of compressor driver, filter, cooling system, blowdown vessel, control system and ESD(Emergency Shut Down) system. And an enclosure package needs to be installed for reducing noise up to 75dB. The system driver is the electronic motor of explosion proof type. Forthe compressor system reliable operation, the cleaning system something like particulate filter needs to be set up in the inlet of compressor and Coalescing Filter in the outlet of compressor. Particulate Filter has to be removed above $10{\mu}m$ size of the particles in biogas. The coalescing filter(Micofine Borosilicate Glass Fibers Filter treated phenol acid) also removes moisture and oil of above $0.3{\mu}m$ to be involved in high pressure biogas up to 90%~98%.

  • PDF

An investigation into the performance of a high-speed synthetic fiber filter employing different types of coagulants (응집제에 따른 합성섬유 여재를 충진한 고속필터의 여과특성에 관한 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.125-139
    • /
    • 2017
  • In this paper, the performance of a synthetic fiber filter aimed at high-speed operation and dosed with different coagulants or filter aids was investigated. Without a coagulant, the filter efficiency was about 62% which was greatly enhanced when three types of coagulants namely PAC, Alum, and $FeCl_3$ were used. Among the coagulants tested, PAC was the most effective, giving 91% filter efficiency, followed by Alum with 90%, and $FeCl_3$ with 78%. PAC worked effectively at a very small range of dose, but Alum was relatively effective in a wide range of concentration. Compared with PAC and Alum, $FeCl_3$ provided more or less contant efficiency regardless of its dose but gave the poorest filter efficiency. Moreover, as the inflow turbidity increased, headloss increased and the efficiency decreased at any dose and type of coagulant. The headloss recorded in this particular synthetic fiber filter is not significant as compared to that observed in typical granular filters. The recovery of solids estimated after filter cleaning was about 80% for both PAC and Alum, but poorer at 72% in the case of $FeCl_3$ due to the heavy and large floc characteristics. The recurrence of filter efficiency verified through repetitive filter runs was found to be satisfactory.