항균처리를 한 공조기기의 항균성능 평가방법과 평가결과

  • Miura, Kunio;Takatsuka, Takesi;Yanagi, U;Yamazaki, Shoji
    • Air Cleaning Technology
    • /
    • v.22 no.2
    • /
    • pp.40-49
    • /
    • 2009
  • Aluminum thin plate coated with epoxy resin containing about 20wt% brass powder, was applied to fins of heat exchanger. We carried out a series of detailed examinations to evaluate the anti-bacterial performance of the plate and heat exchanger (fan coil unit). In the presence of water or moisture, copper ions which have an anti-bacterial ability eluted from brass powder and showed sufficient effects on many kinds of bacteria. We also evaluated the anti-bacterial performance quantitatively by use of the index API (Anti-bacterial Performance Index) which has already been proposed by authors.

  • PDF

CFD Analysis of a Counter-rotating Tubular Type Micro-Turbine with Diffuser (디퓨져를 이용한 튜블러형 상반전 수차의 CFD 성능해석)

  • Lee, Nakjoong;Park, Jihoon;Hwang, Young-Ho;Kim, Youtaek;Lee, Youngho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.205.2-205.2
    • /
    • 2011
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this study, in order to acquire design data of counter-rotating tubular type micro-turbine, output power, head, and efficiency characteristics due to the diffuser.

  • PDF

Comparative study on the efficiency of pesticide residue removal in foods (Perilla Leaves, Strawberries, Apples)

  • Seung-Woon Myung
    • Analytical Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • In agricultural households cultivating vegetables and fruits, the use of various pesticides to protect crops from diseases and pests or to control weeds is widely practiced enhancing quality and productivity. However, pesticides can pose a threat to consumer health by remaining on the food surface or migrating into the food interior. Households commonly peel off skins, wash with water, or use chemical methods to remove foreign substances including residual pesticides on the food surface. In this study, we measured the washing rate by comparing the pesticide concentrations before and after washing in the leafy vegetable perilla leaves and the fruits strawberries and apples, which were intentionally exposed to pesticides. We compared washing rates using tap water, a baking soda solution, and a commercially available food-specific cleaning solution. The target pesticides for analysis were azoxystrobin, bifenthrin, boscalid, difenoconazole, flubendiamide, and indoxacarb, and the residual pesticide analysis was performed using GC-MS/MS or LC-MS/MS. The removal rates of pesticides were highest with the food-specific cleaner, followed by baking soda and tap water in order.

Assessment of microbial quality in household water tanks in Dubai, United Arab Emirates

  • Khan, Munawwar Ali;AlMadani, Asma Mohammad Abdulrahman Ahmad
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.55-60
    • /
    • 2017
  • Provision of safe, accessible, and good water quality in the community is an important step towards reducing various waterborne illnesses. However, improving the quality of water should include spreading awareness to the public regarding the importance of cleaning their household water tanks. The aim of this study was to investigate the microbial quality of water of household water tanks in Dubai. The water samples from household water tanks were collected from forty houses, and a questionnaire was given to the residents to determine the history of the water tanks. The membrane filtration technique was used to quantify heterotrophic and total coliform bacteria on plate count agar and the violet red bile agar respectively. The overall results of this study have shown that 18 out of total 40 household water tanks contained different types of bacteria concentration level beyond local and widely accepted international standards. The overall results of this study indicated that there is a lack of awareness among residents regarding the importance of maintaining proper sanitation and hygiene of the household water tanks.

A Study on the Self-cleaning Surface Finishing Using PFOA Free Fluoric Polymer and Silica Nano-sol (PFOA Free 불소 고분자 및 실리카 나노졸을 이용한 self cleaning 표면 가공에 관한 연구)

  • Park, Sung-Min;Kwon, Il-Jun;Kim, Ran;Yeum, Jeong-Hyun;Yoon, Nam-Sik;Lee, Kyeung-Nam
    • Textile Coloration and Finishing
    • /
    • v.21 no.6
    • /
    • pp.1-11
    • /
    • 2009
  • Super-hydrophobic surface, with a water contact angle greater than $150^{\circ}$, has a self cleaning effect termed 'lotus effect'. We introduced super-hydrophobicity onto aramid/rayon mixture fabric with dual-scale structure by assembling silica nano-sol. Mixture fabric was treated with silica nano-sol, fluoric polymer using various parameters such as particle size, concentration. Silica nano-sol size were measured using particle size analyzer. Morphological changes by particle size were observed using field emission scanning electron microscopy(FE-SEM), contact angle measurement equipment. The contact angle of water was about $134.0^{\circ}$, $137.0^{\circ}$, $143.0^{\circ}$, $139.5^{\circ}$ and $139.0^{\circ}$ for mixture fabric coated with 100.2nm, 313.7nm, 558.2nm, 628.5nm and 965.4nm silica nano-sol, compared with about $120.0^{\circ}$ for mixture fabric coated with fluoric polymer. When we mixed particle sizes of 100.2nm and 558.2nm by 7:3 volume ratio, the contact angle of water was about $146.2^{\circ}$. And we mixed particle sizes of 313.7nm and 558.2nm by 7:3 volume ratio, the contact angle of water was about $141.8^{\circ}$. Also we mixed particle sizes of 558.2nm and 965.4nm by 7:3 volume ratio, the best super-hydrophobicity was obtained. In this paper, we fabricated the water-repellent surfaces with various surface structures by using four types of silica nano-sol, and we found that the dual-scale structure was very important for the super-hydrophobicity.

A Demonstrative Operation of A Membrane Filtration System in Siheung Water Treatment Plant (시흥정수장 막여과시설 시범운영)

  • 김한승;김충환;김학철;윤재경;안효원
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.07a
    • /
    • pp.57-68
    • /
    • 2004
  • A demonstrative operation of a membrane system with its caparity of 3,600m$^3$/d was carried out using reservoir water as raw water for the application of membrane filtration system to drinking water treatment. The operation was undertaken at a constant flux of 0.9 m$^3$/m$^2$/d for three months. Backwashing with NaClO of 3 ppm was allowed for 30 seconds every 20 minutes of filtration. Physical cleaning was introduced after 69 times of filtration/backwashing cycle with air-scrubbing and backwashing for 1 minute, and flushing for 2 minutes. In this study, water treatment performance was investigated compared with the existing rapid sand filtration process. The membrane system was operated with no significant problems during the test period. Higher water quality was obtained in the membrane filtration than in the rapid sand filtration in terms of particulate matters such as turbidity and microbes. Although the finished water of the membrane filtration contained slightly higher concentration in dissolved matters than that of the conventional one, it met the drinking water standard. The demonstrative operation showed that membrane filtration has a reliability in drinking water treatment. Researches should be needed on cost analysis through long-term operation and optimization of operation condition for further application.

  • PDF

A Study on the Cleaning Device of Bidet Washer (비데 세정기의 세척장치에 관한 연구)

  • Lim, Yeon-Jeong;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • This study is about the bidet which is used to clean the anal and local parts after the user seated on the left side of the toilet in the toilet. The cleaner of the bidet which is contaminated from various bacteria and dirt is washed clean with clean water to keep it clean The present invention relates to a cleaning device for a bidet cleaner that hygienically maintains a bidet used by a plurality of users. As a result of developing and studying a bidet nozzle that can be implemented with a bidet nozzle and a washing nozzle for automatically washing the jetting head of the bidet and the jetting head, the optimum jetting time of the nozzle after the hydraulic jetting is 1 second To 10 seconds, it was confirmed that the nozzle cleanliness of an average of 5 seconds was maintained at 100%. Subsequent studies will require further study of the durability of the product and the cleaning safety at a pressure of $5kg/mm^2$. Toilet bidet is a product that is closely related to the safety and life of the people, but the development of various technologies is still insufficient. Therefore, it is meaningful that this study contributed to the quality of life of the people by continuously researching and developing the bidet.

Development of Environmental-friendly Cleaning Agents Utilizing Organic Acids for Removal of Scale on the Wall of Cleaning Beds and Distribution Reservoirs in the Waterworks (유기산을 이용한 상수도 정수장 및 배수지 벽면 스케일 세척용 친환경 세정제 개발)

  • Lee, Jae-Ryoung;Yoon, Hee-Keun;Bae, Jae-Heum;Shin, Hyun-Duk
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.272-279
    • /
    • 2012
  • In this study, an environmental-friendly cleaning agent utilizing organic acids and various additives has been developed and applied to the field for removal of scale deposited on the cleaning beds or distribution reservoirs of the waterworks. As an analytical result of scale on the cleaning beds, we found that it consists of mainly metallic oxides such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, and MnO. Malic acid, malonic acid, and citric acid showed relatively better solvency on $Al_2O_3$, $Fe_2O_3$, and MnO except $SiO_2$ among various organic acids. Mixed organic acid solutions of malic acid, malonic acid, and citric acid were prepared with certain weight ratios and their solvencies on mixed metal oxides of $Al_2O_3$, $Fe_2O_3$, and MnO were investigated. The experimental results showed that an 10% mixed organic acid solution prepared with weight ratio of malic acid : malonic acid : citric acid = 6 : 2 : 2 were found to have best scale solvency power of about 29%. The formulated cleaning agents with a small amount of nonionic surfactant showed much better solvency on mixed oxides than mixed organic solution alone. Especially, the formulated cleaning agent with 0.2 wt% LA-7 surfactant appeared to have best scale removal efficiency of about 35%. However, the formulated cleaning agent with disinfectants such as NaClO, $H_2O_2$ and $Ca(ClO)_2$ showed poor solvency on mixed oxides. It is inferred that surfactants are able to improve scale removal efficiency due to their capability of emulsification, and disinfectants cause to degrade scale solvency in water because of their oxidation. Based on these basic experimental results, formulated cleaning agents have been prepared with mixed organic acid solution, nonionic surfactants, and disinfectants and successfully applied to removal of scales on the cleaning beds and distribution reservoir at city D waterworks.

On a Cleaning of COVID-19 Prevention Masks with Electrolytic Decomposition Water (전기분해수로 코로나방역용 마스크의 세정에 관한연구)

  • Tian, Zhixing;Bae, Myung-Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.591-596
    • /
    • 2022
  • Various COVID-19 quarantine guidelines and measures are being taken by country at the WHO, but the number of confirmed cases has not decreased significantly. In order to prevent the inflow and outflow of COVID-19 through individual droplets, it is mandatory to wear a mask anytime, anywhere. However, as virus bacteria entering the mask amplify, it pollutes the mask and causes a disgusting smell. In this paper, a new method of preventing the spread of COVID-19 was proposed by sterilizing the mask with a dental gait spray introduced into the mask that has been used for a long time. Dental gargle water is usually produced by electrolysis of tap water, and the unstable ion water (HOCl) dissolved in water penetrates the cell barrier of various viruses and fails to act in its nucleus, causing water to self-purify. As a result of the experiment, when the mask used for a long time was washed with gargle water spray, the washed mask was dried after 10 minutes, and the smell of virus droplets or saliva almost disappeared. In particular, as a result of MOS testing the fit of the subjects who participated in the mask cleaning, it was excellent at 4.4 on average. Therefore, the mask was disposable, but if the spray was washed in the proposed method more than twice a day, the mask could be used in a comfortable state for more than a week.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.