• Title/Summary/Keyword: In-vehicle control circuit

Search Result 99, Processing Time 0.024 seconds

Remote Measurement of ECU Sensor Signal based on the Embedded Linux and Web (임베디드 리눅스와 웹 기반의 ECU 센서신호 원격계측)

  • 이현호;최광훈;권대규;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1042-1045
    • /
    • 2003
  • In this paper, we present a new method for the monitoring of Electric Control Unit's(ECU) self-diagnostic and the sensor signals of vehicle through Web. In order to measure the ECU's self-diagnostic and sensor signals, the interfaced circuit is designed to communicate ECU and terminal according to the ISO, SAE regulation of communication protocol standard. Microprocessor 80C196KC is used for communicating ECU's self-diagnostic signals and the results are sent to the Embedded Linux System(ELS) through RF module. ELS is developed by SA1110, RF module, Embedded Linux. All commands related in ECU communication are executed through Web. The CGI program composed in web server is executed by user and will return sensor signals from ECU Software on Embedded Linux system is developed to monitor the ECU's sensor signals using the arm compiler tool chain in which RS232 port is programmed by half duplex method. The possibility for remote measurement of ECU sensor signal through Web is verified through the developed systems and algorithms.

  • PDF

Wireless Power Charging System Capable of Soft-Switching Operation Even in Wide Air Gaps (넓은 공극범위에서 소프트스위칭 동작하는 무선전력 충전시스템)

  • Yu-Jin, Moon;Jeong-Won, Woo;Eun-Soo, Kim;In-Gab, Hwang;Jong-Seob, Won;Sung-Soo, Kang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.515-525
    • /
    • 2022
  • The wireless power transfer (WPT) charging system for AGV depends highly on the coupling conditions due to air gap variation. To attain stable output power with high transfer efficiency under various coupling conditions, a single-stage, DC-DC converter that operates with robustness to changes in air gaps is proposed for the WPT system. The proposed converter is capable of soft switching under the set input voltage (Vin: 380 VDC), load conditions (0-1 kW), and air gap changes (30-70 mm). In addition, a wide output voltage range (Vo: 39-54 VDC) can be controlled by varying the link voltage due to the phase control at a fixed switching frequency. Experimental results are verified using a prototype of a 1 kW wireless power charging system.

Estimating Fatigue Life of APD Electronic Equipment for Activation of a Spaceborne X-band 2-axis Antenna (2축 짐벌식 X-band 안테나 구동용 전장품 APD 제어보드의 피로수명 평가)

  • Jeon, Young-Hyeon;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • While a satellite is carried into orbit by a launch vehicle, it is exposed to the severe launch environment with random vibrations and shock. Accordingly, these vibration sources affect electronic equipment, particularly the printed circuit board (PCB) in the satellite. When the launch load impacts the PCB, it causes negative behavior. This causes perpendicular bending around the boundary of fixation points that finally leads to the failure of solder joints, lead wires, and PCB cracks. To overcome these issues, the electronic equipment design must meet reliability requirements. In this paper, Steinberg's method is used to derive allowable and maximum deflection to verify design from a life perspective concerning the control board of the Antenna Pointing Driver (APD) mounted on KOMPSAT-3.

Development of 6kW ZVS Boost Converter by 4-Parallel Operation (4-병렬 제어 기법을 적용한 6kW 영전압 스위칭 승압형 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • This paper presents development of 6kw ZVS(Zero Voltage Switching) boost converter by 4-parallel operation. To realize a high capacity converter with 6 kw, 4-parallel operation of 1.5kW unit module is proposed in this paper. To meet high ratio input to output voltage, isolated type booster converter is designed. To achieve ZVS operation of 4-switches of full bridge and protect a voltage overshoot caused by switch turn-off, simple active-clamp circuit is applied to the primary side. For parallel operation of 4-modules, master-slave control method is proposed to achieve input current sharing of 4-unit converter modules accurately. For performance tests, simulation is carried out. Also, load and experimental tests of the developed booster converter, 230Vdc/6kW, are carried out under various conditions. For field tests, the developed converter is applied for boosting a battery power to high DC_link voltage for a VSI inverter which starts a micro-turbine(MT) installed in vehicle and it's performance is verified through high speed motoring a MT up to tens of thousands of rpm.

Development of Propulsion Subsystem for KOMPSAST (다목적 실용위성의 추진시스템 개발)

  • 최진철;윤효철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.3
    • /
    • pp.80-89
    • /
    • 1998
  • Propulsion subsystem transfers KOMPSAT into mission orbit and controls its attitude. Design factor consists of structure safety, electrical circuit design, consumable power estimation of thermal hardwares, damping device design of fuel transient pressure, and system configuration design by considering plume effect from thruster firing. System level analysis should be performed for verification of system design under launch vehicle and orbital environment. Electrical functional test of thermal control hardware, proof pressure test, cleanliness verification test, and internal/external leakage test of fuel feeding system should be carried out for performance estimation of propulsion system. Design and assembly process of propulsion subsystem was depicted and reliability of system was verified by test analysis in this paper.

  • PDF

Effect of Internal Circuit Faults of Non-reference Type APS Malfunction on Commercial and Tactical Vehicles (참조센서가 없는 상용/전술차량용 APS내부 회로 불량이 오작동에 미치는 영향)

  • Jo, Yong Jin;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.163-170
    • /
    • 2016
  • In the condition of electronic controlled acceleration system, APS Sensor is the only and the most important parts to reflect the will of driver. Especially, the non-reference type APS is the critical part of this system. It can't provide the cross-reference values and it will make the vehicle goes into the 'NMC(Non-moveable condition)' or 'Limp-home mode' on the malfunction situation easier. If the situation is happened, it's very dangerous condition for the drivers, soldiers and war material systems of battlefield. The electronic control is not a necessary system for the tactical vehicles. The tactical vehicles must be prepared the manual control system independently from the electronic control system to escape, save and rescue the soldier's life and war materials. Therefore it was studied the water-penetrated broken APS output. If the output value was changed without driver's will, even the cross-reference type APS, it will effect the uncontrollable engine RPM changing or the performance down on limp-home mode. It means the manual control system of tactical vehicle is needed for any kinds of APS.

A Study on the Serial-Parallel Resonant DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 직.병렬 공진 DC/DC 컨버터에 관한 연구)

  • Hwang, Gye-Ho;Lee, Bong-Sub;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.31-40
    • /
    • 2008
  • Recently, Contactless Power Supply(CPS) system has been broadly studied as a power supply system for Flat Panel Display(FPD) material transfer equipments. In mass production line, CPS systems on material transfer equipment are applied only in the straight sections with single operating vehicle. The formal CPS system was not adequate for curved section nor multiple operating vehicles. Therefore, this paper presents CPS system that consists of straight and curved section with multiple operation vehicles. The circuit topology of CPS system consists of full bridge configured serial-parallel resonant DC/DC converter. The control method for CPS system consists of duty control method on the primary power supply system to maintain constant resonant current. And the secondary power supply systems of multiple vehicles are self controled to maintain constant output voltage. Practically, the test result of dual vehicles on straight and curved section of material transfer equipments were satisfactory, and proved it's applicability on commercial use.

Development of a battery management system(BMS) simulator for electric vehicle(EV) cars (EV용 배터리 관리시스템(BMS) 시뮬레이터 개발)

  • Park, Chan-Hee;Kim, Sang-Jung;Hwang, Ho-Suk;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2484-2490
    • /
    • 2012
  • This study reports on the development and performance verification of cell simulation boards of simulator and the embedded program for board control of the battery management system (BMS) of electric vehicle (EV) cars, which manages the next-generation automotive lithium-ion battery pack. Here, we have improved the speed of the simulator by using operational (OP) amplifier and transistors that were connected in series. In addition, using a digital analog converter (DAC) in each channel, we have improved the performance by channel-to-channel isolation (isolation) as compared to the traditional methods. Furthermore, by constructing a current-limiting protection circuit, one can be protected from disturbance and, by utilizing a precision shunt resistor for the current sensor, we have increased the precision of the current control. In order to verify the performance of the developed simulator, we have performed the experiment 10 times, with values ranging from 0.5 V to 5 V, and a voltage drop step of 0.5 V. Significance analysis of experimental data, and repeatability tests were performed, showing an average standard deviation of 0.001~0.004 V, indicating high repeatability and high statistical significance of the current method and system.

Thermo-Fluid Simulation for Flow Channel Design of 7kW High-Voltage Heater for Electric Vehicles (전기차용 7kW급 고전압 히터 유로 형상 설계를 위한 열유동 시뮬레이션)

  • Son, Kwon Joong
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.191-196
    • /
    • 2022
  • Unlike an international combustion engine car, a battery-powered electric vehicle requires an additional heat source for its heating system. A high-voltage coolant heater has the advantages of high efficiency and a wide operating temperature range. In its development, the geometry design of the coolant flow path is essential. This paper presents the thermal flow simulations of a 7kW high-voltage heater with symmetric serpentine flow channels arranged parallelly. The heater performance was evaluated from the simulation results in terms of the pressure and temperature differences and the flow uniformity. The proposed design showed a greater flow resistance and similar heat exchanging capability than the existing parallel serpentine design. It has the advantage of a relatively wide low-temperature surface area, where the control circuit board susceptible to high temperatures can be located.