• Title/Summary/Keyword: In-stent restenosis

Search Result 63, Processing Time 0.03 seconds

Numerical Evaluation and Shape Design of Coronary Artery Stent (관상동맥혈관용 스텐트의 수치해석 및 형상 설계)

  • Kim, Dae-Young;Lee, Seung-Yeol;Kim, Heon-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • Restenosis symptom, which is well known as a problem of stents, is due to the recoil and expansion pressure depending on shapes of stent. In order to reduce the effect of recoil problem, study on pattern and shape for the stent is required and the expansion pressure and recoil should be evaluated. This paper aims at evaluating mechanical characteristics of stent used in surgery for vessel stenosis. The expansion process of coronary artery stent in vessel for two models including the Cypher$^{(R)}$ from Johnson & Johnson$^{TM}$ and a suggested model were simulated using the Finite Element Analysis. Comparison of the directional recoil simulation results was made. The issues in the deformed shape of vessel and recoil of Cypher$^{(R)}$ were partially resolved in the suggested model. Therefore, the shape design suggested in this paper was able to reduce the restenosis symptom.

Delayed Carotid Wallstent Shortening Resulting in Restenosis Following Successful Carotid Artery Angioplasty and Stenting

  • Yoon, Seok-Mann;Jo, Kwang-Wook;Baik, Min-Woo;Kim, Young-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.495-497
    • /
    • 2009
  • Carotid angioplasty and stenting (CAS) for carotid stenosis has been increasingly used as an alternative treatment in patients not eligible for surgery. Even though CAS can be performed relatively simply in many cases, various complications can occur. We report four cases of CAS using the Carotid Wallstent, which were complicated by delayed shortening of the stent, resulting in restenosis after successful CAS.

The assessment of the performance of drug-eluting stent using computational fluid dynamics

  • Seo, Tae-Won;Barakat, Abdul I.
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.4
    • /
    • pp.281-288
    • /
    • 2009
  • Numerical investigations have been conducted on the assessment of the performance of drug-eluting stent. Computational fluid dynamics is applied to investigate the flow disturbances and drug distributions released from the stent in the immediate vicinity of the given idealized stent in the protrusion into the flow domain. Our simulations have revealed the drug concentration in the flow field due to the presence of a drug-eluting stent within an arterial segment. Wall shear stress increases with Reynolds number for a given stent diameter, while it increases with stent diameter for a given Reynolds number. The drug concentration is dependent on both Reynolds number and stent geometry. In pulsatile flow, the minimum drug concentration in the zone of inter-wire spacing occurs at the maximum acceleration of the inlet flow while the maximum drug concentration gains at the maximum deceleration of the inlet flow. These results provide an understanding of the flow physics in the vicinity of drug-eluting stents and suggest strategies for optimal performance of drug-eluting stent to minimize flow disturbance.

Effect of Triple Compared to Dual Antiplatelet Therapy After Drug-Eluting Stent Implantation in Percutaneous Coronary Intervention (관상동맥 약물 용출 스텐트 삽입 후 항혈소판제제 3제요법과 2제요법의 임상적 효과 비교)

  • Ye, Kyong-Nam;Kim, Jeong-Tae;Lee, Suk-Hyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.113-122
    • /
    • 2012
  • ACC/AHA/SCAI Guideline recommends for administration dual antiplatelet therapy after drug-eluting stent (DES) to prevent restenosis and stent thrombosis in patients with percutaneous coronary intervention (PCI). Recently triple antiplatelet therapy including cilostazol is known to reduce restenosis and stent thrombosis significantly after DES implantation. However, there is lack of data providing the efficacy of triple antiplatelet therapy. The purpose of this study is to evaluate the clinical effects of the triple therapy after DES implantation compared with the dual therapy. This retrospective study collected data from medical charts of 251 patients who received DES implantation between Jul 2006 and Jun 2008. They received either dual antiplatelet therapy (N = 154 clopidogrel and aspirin; Dual group) or triple antiplatelet therapy (N = 97 cliostazol, clopidogrel and aspirin; Triple group). Major adverse cardiac event rates (MACE, included total death, myocardial infarction, target lesion revascularization) at 12 months, 24 months, stent thrombosis, rates of bleeding complications and adverse drug reactions were compared between these two groups. Compared with the dual group, the triple group had a similar incidence of the MACE rates at 24months (12.3% vs. 12.4%, p = 0.99). There is no difference in overall stent thrombosis between two groups (Dual group 2.6% vs. Triple group 4.1%, p = 0.5). Subgroup analysis showed that diabetic patients got more benefit in reducing MACE rates but, there is no statistical difference. Bleeding complications and adverse drug effects were not different significantly. As compared with dual antiplatelet therapy, triple antiplatelet therapy did not reduce the 12-months, 24-months MACE rates and stent thrombosis. Bleeding complications and adverse drug effects were not different.

A Study of Drug Content and Cell Cytotoxicity of Paclitaxel-eluting Stents Coated with Various Biopolymer (다양한 생체고분자로 코팅된 Paclitaxel Eluting Stent의 약물함량과 세포독성 연구)

  • Kim, Dong-Gon;Shin, Il-Gyun;Kim, Gi-Han;Kim, Seong-Hyeon;Lee, Ju-Ho;Ki, Byoyng-Yun;Nah, Jae-Woon;Suh, Tae-Suk;Kim, Sang-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2009
  • In this study, the paclitaxel eluting stent (PES) was prepared by coating a biliary stent with paclitaxel using various biopolymer such as poly (vinyl acetate) (PVAc), poly (lactic-co-glycolic acid) (PLGA), Silicone rubber for restenosis prevention in gastrointestinal disease by a dip-coating method. Drug contents of PES were increased as surface area of stent, concentration and molecular weight of coating polymer increase. In $^1H-NMR$ specta, we know that drug did not change by confirming specific peaks of paclitaxel in PES. As shown in SEM image, PES prepared using various biopolymer is coated clearly and regularly except Silicone rubber coating polymer. In in vitro cell cytotoxicity test, bare stent showed low cytotoxic effect against CT-26 colon carcinoma cell line on 3 day. However, PES coated with PLGA 502H showed the highest cytotoxicity because PLGA 502H is biodegradable polymer and has less molecular weight than other coating polymer. These results suggest that PES coated various biopolymer can be prevented restenosis in gastrointestinal disease.

  • PDF

A Novel Deposition Method of PLGA Nanoparticles on Coronary Stents

  • Joo, Jae-Ryang;Nam, Hye-Yeong;Nam, So-Hee;Baek, In-Su;Pakr, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1085-1087
    • /
    • 2009
  • Bare metal stents which were used to treat coronary artery disease have several biochemical problems. Polymerbased drug-eluting stents (DES) have opened up a new paradigm in the treatment of in-stent restenosis. Many studies and research programmes have proved that DES can prevent restenosis. In our study, paclitaxel-loaded poly (lactic-co-glycolic acid) (PLGA) nanoparticles have been deposited along the three dimensional scaffold of coronary stents by a method using self-assembling properties of colloidal particles. We found that the nanoparticles were deposited uniformly and closely packed. The amount of paclitaxel was easily controlled by the drug content of the nanoparticles and the deposition count.

Stent Design Using Computational Fluid Dynamics (전산유체역학을 이용한 스텐트 설계)

  • Kim, Tae-Dong;Barakat, Abdul;Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1042-1048
    • /
    • 2005
  • Numerical investigation has been made on the stent design to minimize the neointimal hyperplasia. Computational fluid dynamics is applied to investigate the flow distributions in the immediate vicinity of the given idealized stent implanted in the blood vessel. Parametric study on the variations of the number of stouts, stent diameters, stent spacings and Reynolds numbers has been conducted using axi-symmetric Navier-Stokes equations. An initial difficulty in the study is to determine the optimal stent design to understand the flow physics of the flow disturbance induced by stent. The size of recirculation zone around stent is depend on the stent diameter, number of stent wire and Reynolds number but is insensitive to the stent wire spacing. It is also found that when the flow is in acceleration, the flow sees a more favorable pressure gradient, and the separation zones are smaller than the steady flow case. When the flow is in deceleration and the flow sees a more adverse pressure gradient so that the separation zones are larger.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Spontaneous resolution of new coronary artery aneurysm following guideline-directed medical therapy after drug-eluting stent implantation

  • Jae-Geun Lee;Ki Yung Boo
    • Journal of Medicine and Life Science
    • /
    • v.20 no.3
    • /
    • pp.131-134
    • /
    • 2023
  • Here, we present a case of a 56-year-old man with acute myocardial infarction. The patient underwent percutaneous coronary intervention (PCI) at the left main bifurcation and mid-left anterior descending artery using drugeluting stents. Four months after the PCI, the patient was readmitted for cardiac arrest. Coronary angiography (CAG) revealed stent thrombosis in the left main-to-proximal left anterior descending artery and in-stent restenosis in the left main-to-proximal left circumflex artery. We performed balloon angioplasty at the left main to mid-left anterior descending artery and left main to proximal left circumflex artery stents; subsequently, blood flow was fully restored. However, contrast agent extravasation was observed outside the mid-portion of the left main artery to the proximal left anterior descending artery stent, indicating the presence of a coronary artery aneurysm (CAA) outside the stent. After guideline-directed medical therapy with dual antiplatelet agents and high-intensity statins, follow-up CAG revealed near-resolution of the CAA, absence of stenotic lesions, and good blood flow.