• Title/Summary/Keyword: In-process Detection

Search Result 3,508, Processing Time 0.036 seconds

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

CYTOTOXIC EFFECTS OF SOLUBLE EXTRACTS FROM RERIODONTAL DRESSINGS ON HUMAN GINGIVAL FIBROBLASTS (치은 섬유아세포에 대한 치주포대 추출물의 세포동성에 관한 연구)

  • Yang, Seung-Han;Lee, Man-Sup;Park, Joo-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.3
    • /
    • pp.661-670
    • /
    • 1994
  • It is well known that the application of dressings after periodontal surgery have benefits to provide the comforts to patient and to promote the healing process with action of bleeding control and temporary stabilization for the operated mobile teeth. But until recently the relationship between periodontal dressings and cells which are composed of periodontium has not been clear. The purpose of this study was to evaluate the cytotoxic effect of soluble extracts from the four different kinds of periodontal dressings, two of them were eugenol type (K.H.pack, Wondrpak) and the others were non-eugenol type (Coe-pak, Periocare), on the human gingival fibroblasts in vitro. Human gingival fibroblasts were primarily cultured from gingiva around third molar during the extraction for preventive purposes. Extracts solution were prepared with culture medium by means of imersing the consistent size of periodontal dressing made from plastic mold. Cell were inoculated into the 24 well plate with $3\;{\times}\;10^4\;cells/well$ of medium at $37\;^{\circ}C$, 100% of humidity, 5% of $CO_2$, incubator for 24 hours. After discard of the supernatant of medium, those cells were cultured with original, 1/2, 1/5, 1/10 diluted soluble extract for 24, 48 and 72 hours, and counted the number of cells using the hemocytometer at each designed time and concentration. Also, the cytotoxic effect of soluble extract was measured by Wataha's MTT assay method. In briefly, cells were inoculated and cultured into 96 well culture plate with $2\;{\times}\;10^4\;cells/well$ for 24 hours. Soluble extracts were applied to cultured cells and incubated for 48 hours at same condition. $50\;{\mu}l$ of MTT solution and DMSO were added into each well for the detection of absorbance with ELISA reader. The measured data were calculated by value of colorimetric assay for survival rate. The results were as follows ; In the case of eugenol type of dressing, original, 1/2 and 1/5 diluted extracts of K.H.pack showed very low survival rate. And original extract of Wondrpak showed strong cytotoxic effect and 1/2 diluted extract showed moderate cytotoxic effect. In the case of Non-eugenol type of dressings, only original extract of Coe-pak revealed strong cytotoxic effect and Periocare had little cytotoxic effect. It is concluded that eugenol type of dressings showed more cytotoxic effect than non-eugenol types. This study suggest that use of non-eugenol dressings after periodontal surgery is recommended.

  • PDF

A Signal Processing Technique for Predictive Fault Detection based on Vibration Data (진동 데이터 기반 설비고장예지를 위한 신호처리기법)

  • Song, Ye Won;Lee, Hong Seong;Park, Hoonseok;Kim, Young Jin;Jung, Jae-Yoon
    • The Journal of Society for e-Business Studies
    • /
    • v.23 no.2
    • /
    • pp.111-121
    • /
    • 2018
  • Many problems in rotating machinery such as aircraft engines, wind turbines and motors are caused by bearing defects. The abnormalities of the bearing can be detected by analyzing signal data such as vibration or noise, proper pre-processing through a few signal processing techniques is required to analyze their frequencies. In this paper, we introduce the condition monitoring method for diagnosing the failure of the rotating machines by analyzing the vibration signal of the bearing. From the collected signal data, the normal states are trained, and then normal or abnormal state data are classified based on the trained normal state. For preprocessing, a Hamming window is applied to eliminate leakage generated in this process, and the cepstrum analysis is performed to obtain the original signal of the signal data, called the formant. From the vibration data of the IMS bearing dataset, we have extracted 6 statistic indicators using the cepstral coefficients and showed that the application of the Mahalanobis distance classifier can monitor the bearing status and detect the failure in advance.

A Study of a Fast Booting Technique for a New memory+DRAM Hybrid Memory System (뉴메모리+DRAM 하이브리드 메모리 시스템에서의 고속부팅 기법 연구)

  • Song, Hyeon Ho;Moon, Young Je;Park, Jae Hyeong;Noh, Sam H.
    • Journal of KIISE
    • /
    • v.42 no.4
    • /
    • pp.434-441
    • /
    • 2015
  • Next generation memory technologies, which we denote as 'new memory', have both non-volatile and byte addressable properties. These characteristics are expected to bring changes to the conventional computer system structure. In this paper, we propose a fast boot technique for hybrid main memory architectures that have both new memory and DRAM. The key technique used for fast booting is write-tracking. Write-tracking is used to detect and manage modified data detection and involves setting the kernel region to read-only. This setting is used to trigger intentional faults upon modification requests. As the fault handler can detect the faulting address, write-tracking makes use of the address to manage the modified data. In particular, in our case, we make use of the MMU (Memory Management Unit) translation table. When a write occurs to the boot completed state, write-tracking preserves the original state of the modified address of the kernel region to a particular location, and execution continues. Upon booting, the fast booting process restores the preserved data to the original kernel region allowing rapid system boot-up. We develop the fast booting technique in an actual embedded board equipped with new memory. The boot time is reduced to less than half a second compared to around 15 seconds that is required for the original system.

Determination of Tributyl Phosphate Degradation Products by Ion Chromatography (이온크로마토그래피에 의한 Tributyl Phosphate(TBP) 분해산물의 정량)

  • Han, Sun Ho;Lee, Hyo Jin;Yang, Han Beom;Park, Yang Soon;Joe, Kih Soo
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.329-334
    • /
    • 2002
  • Tributyl phosphate(TBP) is used in solvent extraction process for radioactive waste. This compound may be degraded to dibutyl phosphate($DBP^-$), monobutyl phosphate($MBP^{2-}$) and ${PO_4}^{3-}$ by radioactive material. Amount of $DBP^-$ and $MBP^{2-}$ in TBP must be monitored because they production of these compounds means degradation of which leads to a decrease in the extraction yield. Retention behavior for $DBP^-$, $MBP^{2-}$, $F^-$, $Cl^-$, ${NO_2}^-$, ${NO_3}^-$, ${SO_4}^{2-}$ and ${PO_4}^{3-}$ are studied with AS4A-SC(Dionex) analytical column and $Na_2CO_3$/NaOH eluent by Ion chromatography. Optimum condition for these anions is 2 mM $Na_2CO_3$/1 mM NaOH eluent. All anions by this condition is well separated within 15min. Dynamic range is $10{\mu}g/mL$ - $100{\mu}g/mL$ for DBP and $5{\mu}g/mL$ - $50{\mu}g/mL$ for $MBP^{2-}$, respectively. The Detection limit for AS4A-SC are $1{\mu}g/mL$ for $DBP^-$ and $0.5{\mu}g/mL$ for $MBP^{2-}$ in this system with a $25{\mu}L$ sample loop.

Residues of sulfadimethoxine in blood and liver of cultured olive flounder Paralichthys olivaceus by oral administration (Sulfadimethoxine의 경구 투여에 따른 넙치, Paralichthys olivaceus 혈액 및 간에서의 잔류량 변화)

  • Jun, Sung-Hee;Kim, Jin-Woo;Seo, Jung-Soo;Jee, Bo-Young;Park, Myoung-Ae
    • Journal of fish pathology
    • /
    • v.25 no.2
    • /
    • pp.95-101
    • /
    • 2012
  • The residue levels of sulfadimethoxine (SDM) was studied after oral administration to cultured olive flounder, Paralichthys olivaceus at $20{\pm}1.0^{\circ}C$. The concentrations of SDM in the plasma and liver were determined by HPLC-UV detector after a single dosage of 400 mg/kg body weight. The average recoveries of SDM in spiked samples between 2~50 ppm were 92.24~93.62% for plasma and 88.34~91.90% for liver. Limit of detection for SDM was 0.05 ppm by using this method. Samples were taken at 1 h, 6 h, 12 h, 24 h, 48 h, 72 h, 168 h, 240 h, 336 h and 480 h post-dose. The peak plasma and liver concentrations of SDM, which attained at 1 h post-dose, was $402.64{\pm}59.66{\mu}g/ml$ and $238.18{\pm}54{\mu}g/g$, respectively. Thereafter, it's elimination from both tissues was considerably faster following process of time. Their concentrations of SDM were not measurable at 480 h post-dose. Based on this results, dosage and withdrawal times for SDM could be used when it is prescribed with SDM in olive flounder.

A Study on the DID based Smart Remocon and FIDO Transaction Certification for Home-shopping (DID 기반의 스마트 리모콘과 홈쇼핑 FIDO 거래인증 연구)

  • Yeo, Hyupgoo;Kang, Mingoo;Sonh, Seungil
    • Smart Media Journal
    • /
    • v.9 no.1
    • /
    • pp.60-66
    • /
    • 2020
  • In this paper, the FIDO (Fast IDentity Online) transaction certification platform was proposed for applying the DID (Decentralized ID) of blockchain with home shopping channels to the IPTV service providers based on the Remocon (Remote Control). In this case, the DID based smart remocon applies biometric identification techniques for personal identification. These individual DID smart remote controls apply distributed ID blockchain, enabling home shopping viewers to conduct reliable ratings surveys through the detection of channel changed information. In addition, this smart remocon utilizes the product purchased information history on home shopping channels, allowing IPTV's home shopping viewers to compare the same broadcasted production information on all channels by blockchain technique and their production characteristics. IPTV service providers can process home shopping order/authorization informations in one-stop service via a number of home shopping broadcasting companies, and DID smart remote controls for home shopping viewers with the checking results of their real-time online access to confirm the FIDO2.0 transaction certification homepage. Thus, the FIDO transaction authentication platforms of IPTV service provider(Telecommunication company) can be expected to improve the benefits of home shopping customers, and to reduce the broadcasting companies' burden of payment, too.

Evaluation on Extraction Conditions and HPLC Analysis Method for Bioactive Compounds of Astragali Radix (황기의 추출조건 및 유효성분의 HPLC 분석법 평가)

  • Kim, Geum Soog;Lee, Dae Young;Lee, Seung Eun;Noh, Hyung Jun;Choi, Je Hun;Park, Chun Geun;Choi, Soo Im;Hong, Seung Jae;Kim, Seung Yu
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.6
    • /
    • pp.486-492
    • /
    • 2013
  • This study has been conducted to establish the optimal extraction process and HPLC analysis method for the determination of marker compounds as a part of the materials standardization for the development of health functional food materials from Astragali radix. Five extraction conditions including the shaking extraction at room temperature and the reflux extraction at $85^{\circ}C$ with 30%, 50% and 95% ethanol were evaluated. Reflux extraction with 50% ethanol showed the highest extraction yield as $27.27{\pm}2.27%$, while the extraction under reflux with 95% ethanol showed significantly the lowest yield of $10.55{\pm}0.24%$. The quantitative determination methods of calycosin-7-O-${\beta}$-D-glucoside and calycosin as marker compounds of Astragali radix extracts were optimized by HPLC analysis using a Thermo Hypersil column ($4.6{\times}250mm$, $5{\mu}m$) with the gradient elution of water and acetonitrile as the mobile phase at the flow rate of $0.8mLmin^{-1}$ and a detection wavelength of 230nm. The HPLC/UV method was applied successfully to the quantification of two marker compounds in Astragali radix extracts after validation of the method with the linearity, accuracy and precision. The contents of calycosin-7-O-${\beta}$-D-glucoside and calycosin in 50% ethanol extracts by reflux extraction were significantly higher as $1,700.3{\pm}30.4$ and $443.6{\pm}8.4{\mu}g-1$, respectively, comparing with those in other extracts. The results indicate that the reflux extraction with 50% ethanol at $85^{\circ}C$ is optimal for the extraction of Astragali radix, and the established HPLC method are very useful for the evaluation of marker compounds in Astragali radix extracts to develop the health functional material from Astragali radix.

Positive Random Forest based Robust Object Tracking (Positive Random Forest 기반의 강건한 객체 추적)

  • Cho, Yunsub;Jeong, Soowoong;Lee, Sangkeun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.107-116
    • /
    • 2015
  • In compliance with digital device growth, the proliferation of high-tech computers, the availability of high quality and inexpensive video cameras, the demands for automated video analysis is increasing, especially in field of intelligent monitor system, video compression and robot vision. That is why object tracking of computer vision comes into the spotlight. Tracking is the process of locating a moving object over time using a camera. The consideration of object's scale, rotation and shape deformation is the most important thing in robust object tracking. In this paper, we propose a robust object tracking scheme using Random Forest. Specifically, an object detection scheme based on region covariance and ZNCC(zeros mean normalized cross correlation) is adopted for estimating accurate object location. Next, the detected region will be divided into five regions for random forest-based learning. The five regions are verified by random forest. The verified regions are put into the model pool. Finally, the input model is updated for the object location correction when the region does not contain the object. The experiments shows that the proposed method produces better accurate performance with respect to object location than the existing methods.

Competitive Extraction of Chlorinated Solvents by Headspace SPME GC/FID (Headspace SPME GC/FID를 이용한 Chlorinated Solvents의 경쟁적 추출효과에 관한 연구)

  • An, Sangwoo;Kim, Youngju;Chun, Sukyoung;Lee, Sijin;Park, Jaewoo;Chang, Soonwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.5
    • /
    • pp.61-67
    • /
    • 2010
  • In this study, Solid-phase microextraction (SPME) with GC/FID was studied as a possible alternative to liquid-liquid extraction for the analysis of chlorinated solvents (PCE and TCE) and these by-products (cis-DCE, VC, and Ethylene). Experimental parameters affecting the SPME process (such as kind of fibers, adsorption time, desorption time, volume ratio of sample to headspace, salt addition, and magnetic stirring) were optimized. Experimental parameters such as CAR/PDMS, adsorption time of 20 min, desorption time of 5 min at $250^{\circ}C$, headspace volume of 50mL, sodium chloride (NaCl) concentration of 25% combined with magnetic stirring were selected in optimal experimental conditions for analysis of chlorinated solvents and these by-products. The general affinity of analytes to CAR/PDMS fiber was high in the order PCE>TCE>cis-DCE>VC>Ethylene. The linearity of $R^2$ for chlorinated solvents and these by-products was from 0.912 to 0.999 when analyte concentrations range from $10{\mu}g/L$ to $500{\mu}g/L$, respectively. The relative standard deviation (% RSD) were from 2.1% to 3.6% for concentration of $500{\mu}g/L$ (n=5), respectively. Finally, the limited of detection (LOD) observed in our study for chlorinated solvents and these by-products were from $0.5{\mu}g/L$ to $10{\mu}g/L$, respectively.