Quantifying Aberrations on Object Plane Using Zernike Polynomials

  • Yohan Kim;Theo Nam Sohn;Cheong Soo Seo;Jin Young Sohn
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.151-155
    • /
    • 2024
  • Optical systems often suffer from optical aberrations caused by imperfect hardware, which places significant constraints on their utility and performance. To reduce these undesirable effects, a comprehensive understanding of the aberrations inherent to optical systems is needed. This article presents an effective method for aberration detection using Zernike polynomials. The process involves scanning the object plane to identify the optimal focus and subsequently fitting the acquired focus data to Zernike polynomials. This fitting procedure facilitates the analysis of various aberrations in the optical system.

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

A Study on the Analysis of the Error in Photometric Stereo Method Caused by the General-purpose Lighting Environment (測光立體視法에서 범용조명원에 기인한 오차 해석에 관한 연구)

  • Kim, Tae-Eun;Chang, Tae-Gyu;Choi, Jong-Soo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.11
    • /
    • pp.53-62
    • /
    • 1994
  • This paper presents a new approach of analyzing errors resulting from nonideal general-purpose lighting environment when the Photometric Stereo Method (PSM) is applied to estimate the surface-orientation of a three-dimensional object. The approach introduces the explicit modeling of the lighting environment including a circular-disk type irradiance object plane and the direct simulation of the error distribution with the model. The light source is modeled as a point source that has a certain amount of beam angle, and the luminance distribution on the irradiance plane is modeled as a Gaussian function with different deviation values. A simulation algorithm is devised to estimate the light source orientation computing the average luminance intensities obtained from the irradiance object planes positioned in three different orientations. The effect of the nonideal lighting model is directly reflected in such simulation, because of the analogy between the PSM and the proposed algorithm. With an instrumental tool designed to provide arbitrary orientations of the object plane at the origin of the coordinate system, experiment can be performed in a systematic way for the error analysis and compensation. Simulations are performed to find out the error distribution by widely varying the light model and the orientation set of the object plane. The simulation results are compared with those of the experiment performed in the same way as the simulation. It is confirmed from the experiment that a fair amount of errors is due to the erroneous effect of the general-purpose lighting environment.

  • PDF

Improvement of Depth Video Coding by Plane Modeling (평면 모델링을 통한 깊이 영상 부호화의 개선)

  • Lee, Dong-Seok;Kwon, Soon-Kak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.5
    • /
    • pp.11-17
    • /
    • 2016
  • In this paper, we propose a method of correcting depth image by the plane modeling and then improving the coding performance. We model a plane by using the least squares method to the horizontal and vertical directions including the target pixel, and then determine that the predicted plane is suitable from the estimate error. After that, we correct the target pixel by the plane mode. The proposed method can correct not only the depth image composed the plane but also the complex depth image. From the simulation result that measures the entropy power, which can estimate the coding performance, we can see that the coding performance by the proposed method is improved up to 80.2%.

REQUIREMENTS AND FEASIBILITY STUDY OF FPC-G FINE GUIDING IN SPACE INFRARED TELESCOPE, SPICA (대형 적외선 우주망원경 SPICA/FPC-G의 정밀 별추적 요구사항과 타당성 연구)

  • Jeong, Woong-Seob;Lee, Dae-Hee;Pyo, Jeonghyun;Moon, Bongkon;Park, Sung-Joon;Ree, Chang Hee;Park, Youngsik;Han, Wonyong;Nam, Ukwon;Matsumoto, Toshio
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.5
    • /
    • pp.391-397
    • /
    • 2012
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. It will achieve the high resolution as well as the unprecedented sensitivity from mid to far-infrared range. The FPC (Focal Plane Camera) proposed by KASI as an international collaboration is a near-infrared instrument. The FPC-S and FPC-G are responsible for the scientific observation in the near-infrared and the fine guiding, respectively. The FPC-G will significantly reduce pointing error down to below 0.075 arcsec through the observation of guiding stars in the focal plane. We analyzed the pointing requirement from the focal plane instruments as well as the error factors affecting the pointing stability. We also obtained the expected performance in operation modes. We concluded that the FPC-G can achieve the pointing stability below 0.075 arcsec which is the requirement from the focal plane instruments.

Error Analysis of Trilateration Network by Confidence Ellipse (신뢰타원에 의한 삼변망의 오차해석)

  • 백은기;구재동
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 1995
  • Error analysis is important in horizontal positioning. In case of error analysis, standard error ellipse is generally used to establish the precision regions, but it will be replaced by 95% confidence ellipse. It is more effective than standard error ellipse in resection for measured procedures and establishment for criterias of relative error. Therefore, In this paper deals with analysis of application to 95% confidence ellipse in horizontal positioning. This study deals with error analysis of plane trilateration network which are various types of control point. also, this paper have studied for theory of error analysis in order to using least square adjustment. Thus, This paper's conclusion are as follows; 95% confidence ellipse could be used to establish of specification in korea, also, it is possible for us to predesign for optimum surveying network by 95% confidence ellipse.

  • PDF

Organization of Circular Motion Accuracy Measuring System of NC Lathe using Linear Scales (리니어 스케일을 이용한 NC 선반의 원 운동정도 측정 시스템의 구성)

  • Kim Young Seuk;Kim Jae Yeol;Kim Jong Kwan;Han Ji Hee;Jung Jung Pyo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.1-6
    • /
    • 2004
  • Measurements of circular motion accuracy of NC lathe have achieved with ball bar systems proposed by Bryan, but the ball bar systems have ifluenced on the measuring data by way of the accuracy of the balls and the contacts of balls and bar seats. Therefore in this study, error data during of circular motion of ATC(Automatic Tool Changer) of NC lathe will be acquired by reading zx plane coordinates using two optical linear scales. Two optical linear scales of measuring unit are fixed on z-x plane of NC lathe, and the moving part is fixed to ATC and then is made to receive data of coordinates of the ATC at constant time intervals using tick pulses comming out from computer. And then, error data files of radial direction of circular motion are calculated with the data read, and the aspect of circular motion are modeled to plots, and are analysed by means of statistical treatments of circularity, means, standard deviations etc.

Comparison of Cone Model Parameters for Halo Coronal Mass Ejections

  • Na, Hyeon-Ock;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.96.1-96.1
    • /
    • 2011
  • Halo coronal mass ejections (HCMEs) are major cause of the geomagnetic storms. To minimize the projection effect by coronagraph observations, we consider two CME cone models: an ice-cream cone model and an asymmetric cone model. These models allow us to determine three dimensional parameters of HCMEs such as radial speed, angular width, and the angle between sky plane and cone axis. In this study, we compare these parameters obtained from both models using 50 well-observed HCMEs from 2001 to 2002. Then we obtain the root mean square error (RMS error) between measured projection speeds and estimated ones for the models. As a result, we find that the radial speeds obtained from the models are well correlated with each other (R=0.89), and the correlation coefficient of angular width is 0.68. The correlation coefficient of the angle between sky plane and cone axis is 0.42, which is much smaller than what is expected. The reason may be due to the fact that the source locations of the asymmetric cone model are assumed to be near the center. The average RMS error of the asymmetric cone model (86.2km/s) is slightly smaller than that of the ice-cream cone model (88.6km/s).

  • PDF

A Study on Three-dimensional Coordinates Analysis Using Mirror Images (거울영상을 이용한 3차원 좌표해석에 관한 연구)

  • 유복모;이현직;정영동;오창수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.4 no.1
    • /
    • pp.25-36
    • /
    • 1986
  • Minimum three pairs of model are necessary to determine absolute coordinates of three-dimensional objects. This paper researches the method of analyzing three-dimensional coordinates of all sides of objects by photographing a pair of stereo model through the medium of mirror. An objective lies in improving the accuracy and the efficiency of mirror images method by introducing an error correction function for distortion of the mirror. Projected-onto-mirror points are transformed on the object plane through mirror plane equation. As the result, X-coordinates error is the largest and Y, Z-coordinates error represents about 1mm. Also, accuracy can be improved by introducing correction function for left and right mirror and correcting the distortion of mirror.

  • PDF

The design of XYZ 3-axis stage for AFM system (AFM 시스템을 위한 XYZ 3축 스테이지의 설계)

  • 김동민;김기현;심종엽;권대갑;엄천일
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.36-36
    • /
    • 2002
  • To Establish of standard technique of length measurent in 2D plane, we develope AFM system. The XY scanner scans the sample only in XY plane, while the Z scanner scans the specimen only in Z-direction. Cantilever tip is controlled to has constant height relative to speciman surface by feedback of PSPD signal. To acquire high accuracy, Z-axis measuring sensor will be added.(COXI or others). In this paper we design XYZ stage suitable for this AEM system. For XY stage, single module parallel-kinnematic flexure stage is used which has high orthogonality and minimum out-of-plane motion. To obtain best performance optimal design is performed. For XY stage, to be robust about parasitic motion optimal design of maximizing Z and tilt stiffness is performed under the constraint of motion range and stage size. And for Z stage, optimal design of maximizing 1st resonant frequency is performed. Because if resonant frequency is get higher, scan speed is improved. So it makes reduce the error by sensor drift. Resultly XYZ stage each have 1st natural frequency of 115㎐, 201㎐, 2.66㎑ and range 109㎛, 110㎛, 12㎛.