• 제목/요약/키워드: In-plane alignment

검색결과 174건 처리시간 0.023초

슬관절 전치환술 초기의 대퇴사두근 운동 방법에 따른 슬관절과 족관절의 관상면 정렬 비교: 하지 등척성 동시수축과 대퇴사두근 단독 등척성 수축 (A Comparison of Knee and Ankle Coronal Plane Alignment According to Quadriceps Exercise Method in Early Phase of Total Knee Arthroplasty: Lower Extremity Isometric Co-Contraction and Quadriceps Isolated Isometric Contraction)

  • 김형수;정영희
    • 한국전문물리치료학회지
    • /
    • 제23권1호
    • /
    • pp.20-30
    • /
    • 2016
  • Background: Total knee arthroplasty (TKA) recovers the alignment of the knee joint, but fails to automatically restore the alignment and function of the hip and ankle joints. It may affect the alignment and stability of the knee joint, therefore therapeutic intervention in hip and ankle joint is necessary for the rehabilitation process after TKA. Objects: The aim of this study was to comparison of the effects of the two exercise methods on the coronal plane alignment after TKA. This study conducted an experiment by dividing subjects into a lower extremity isometric co-contraction group (LEIC) and a quadriceps isolated isometric contraction (QIIC) group. Methods: A total of 37 subjects were randomly assigned to the LEIC ($n_1$=19) or the QIIC ($n_2$=18). Exercise was applied to five times per week for three weeks, starting on the eighth day after surgery. Range of motion exercises were performed as a common intervention and then each group performed quadriceps isometric contraction exercises with 10 sets of 5 repetitions. Radiological imaging was performed prior to surgery, one month and six months after surgery. In addition, the hip-knee-ankle angle (HKA) and tibiotalar angle (TTA) were measured. Results: The HKA was close to neutral in the LEIC rather than the QIIC (p<.05). The LEIC showed varus and the QIIC exhibited valgus TTA (p<.05). In a comparison of HKA and TTA over time, there was no significant change in either group (p>.05). According to the comparison of the TTA before surgery, the LEIC showed significant changes in the varus direction (p<.05), while there was no significant change in the QIIC (p>.05). Conclusion: The LEIC method triggered changes in the TTA and brought the HKA close to the neutral. Thus, LEIC is more effective than QIIC in creating stability in the coronal plane alignment of the knee and ankle joints after TKA.

3차원적 동작 분석기를 이용한 건강한 여자 노인의 하지 정렬 상태와 슬관절 내전 모멘트의 상관 관계에 관한 연구 (3-Dimensional Gait analysis and the relationship between lower limb alignment and knee adduction moment in elderly healthy women)

  • 조유미;이완희
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.90-101
    • /
    • 2003
  • Gait analysis can provide a better understanding of how the alignment of the lower limb and foot can contribute to force observed at the knee. Anatomic and mechanical factors that affect loading in the knee pint can contribute to pathologic change seen at the knee in degenerative pint disease and should be considered in treatment plan. The purpose of this study is to present the gait analysis data and to determine whether there is any relationships between alignment of the lower limb, foot progression angle and knee pint moments in elderly healthy women with 3-dimensional motion analyzer. The results were as follows; 1. Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04 m, Step length was 0.56 m. 2. According to the parameters of kinematics, the maximal knee flexion angle through swing phase showed left $46.82^{\circ}$, right $40.19^{\circ}$ and the maximal knee extension angle showed left $-1.32^{\circ}$, right $2.01^{\circ}$. knee varus showed left $26.90^{\circ}$, right $30.93^{\circ}$. 3. Moment, one of kinetic parameters of knee pint the maximal flexion moment showed left 0.363. Nm/kg, right 0.464 Nm/kg and maximal extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximal. adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg and the maximal internal rotatory moment showed left 0.13 Nm/kg, right 0.140 Nm/kg. 4. On sagittal plane, the maximal power of knee joint showed left 0.571 J/kg, right 0.629 J/kg. On coronal plane, the maximal power of knee joint showed left 0.11 J/kg, right 0.12 J/kg. On transverse plane, the maximal power of knee joint showed left 0.058 J/kg, right 0.072 J/kg. 5. The subject who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase. 6. The subject who had large foot progression angle had statistically lower in knee adduction moment in late stance phase. A relationship was observed between the alignment of the lower extremity and the adduction moment of the knee joint during stance phase. Hence, we need some research to figure, out the change of adduction moment according to the sort of knee joint osteoarthritis and the normal geriatrics as well. And we also require more effective, specific therapeutic program by making use of those background of researches.

  • PDF

DC Influence Between Pixel Electrode and Alignment Layer in In-plane Switching Mode LCD

  • Lim, Young-Nam;Lee, Tae-Rim;Park, Byoung-Gyu;Roh, Seung-Kwang;Kim, Hyun-Chul;Kim, Hyun-Seung;Kim, Kyeong-Jin;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.677-680
    • /
    • 2009
  • DC influence between pixel electrode and alignment layer (AL) in in-plane switching mode LCD was analyzed through DC equivalence-circuit equation induction, DC charge-discharge simulation, luminance and residual-DC measurement systems using test patterned (TP) cell. DC discharging rate (DDR) of single layer electrode was faster than that of double layer electrode and DDR of low resistance AL was faster than that of high resistance AL. DC discharging characteristics had a close relation to layer number and resistance between two electrodes.

  • PDF

다채널 광정렬 장치 로터리 스테이지 개발에 관한 연구 (A Study on the Development of the Rotary Stage for Multi-Channel Optical Alignment System)

  • 정상화;차경래
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.143-148
    • /
    • 2003
  • In recent years, as the optical Communication systems are developed, the demands of essential parts such as splitter, coupler, WDM, and AWG filter are grow rapidly. The fabrication process for them is not, however, automatic. On that reason, the automation is needed for the grow of productivity. The optical alignment and attach ment is the core process in fabrication. In this paper, the 6-axis rotary stage for multi-channel optical alignment system is developed and the dynamic characteristic of this system is studied.

  • PDF

광전소자 패키징에서 광섬유 정렬을 위한 Si V-groove 형성 (The formation of Si V-groove for optical fiber alignment in optoelectronic devices)

  • 유영석;김영호
    • 마이크로전자및패키징학회지
    • /
    • 제6권3호
    • /
    • pp.65-71
    • /
    • 1999
  • 광 패키징에서 광섬유와 광전자소자를 정확히 정렬하기 위한 V-groove의 치수 정밀도에 미치는 마스크 재료와 에칭용액의 영향을 연구하였다. PECVD nitride, LPCVD nitride, thermal oxide($SiO_2$)를 마스크재료로 사용하였고 실리콘을 이방성에칭하는 용액으로 KOH(40wt%)용액과 KOH(40wt%)용액에 IPA를 첨가한 용액을 이용하였다. 마스크재료로는 LPCVD nitride가 가장 좋은 선택적에칭특성을 나타내었으며 사용된 마스크재료 중 thermal oxide가 가장 빠른 속도로 에칭되었다. V-groove의 크기 증가는 마스크충 아래로의 undercutting에 의해 생겼는데 이는 주로 (111)면으로의 에칭 때문이었다. KOH(40wt%)용액에서 (111)면의 에칭속도는 0.034 - 0.037 $\mu\textrm{m}$/min로 마스크재료에 관계없이 거의 일정하였다. IPA를 KOH(40wt%)용액에 첨가하면 (100)면과 (111)면의 에칭속도는 모두 감소하지만 (111)면에 대한 (100)면의 에칭속도비는 증가하였다. 그러므로 이런 용액에서 (111)면으로의 에칭에 의한 undercutting현상은 줄어들었으며 V-groove의 크기를 더 정확하게 조절할 수 있었다.

  • PDF

다채널 광정렬 장치에서의 다자유도 회전 스테이지 동작 특성에 관한 연구 (A Study on the Mechanism of Rotational Stage with Multi Degree of Freedom for Multi-Channel Optical Alignment System)

  • 정상화;차경래;최석봉;김광호;박준호;이경형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.219-224
    • /
    • 2004
  • In recent years, as the demands of VBNS(Very high speed Backbone Network Service) and VDSL(Very high-data rate Digital Subscriber Line) increase, the development of kernel parts of optical communication such as PLC(Planar Light Circuit), Coupler, WDM elements increase. The alignment and the attachment technology are very important to fabricate the optical elements for communication. In this paper, the mechanism of rotational stage, the contact sensing unit, and integrated control circuit for the optical alignment system are studied.

  • PDF

Tilted Homeotropic Alignment using Ion Beam Process; Development of Novel Inorganic thin films

  • Hwang, Byoung-Har;Kim, Kyung-Chan;Ahn, Han-Jin;Kim, Jong-Bok;Baik, Hong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.450-452
    • /
    • 2005
  • The ion beam alignment technique is one of the potential and fascinating methods. However, there are merely a few reports about aligning nematic liquid crystals (NLCs) horizontally for in-plane switching mode (IPS) by means of low energy ion beam exposure on inorganic materials such as DLC. In this study, we have investigated the tilted vertical alignment of NLC by the ion beam technique on the thin films of various amorphous silicon compounds as new inorganic alignment materials. Appropriate pretilt angles of NLC with preferred orientation on these thin films were achieved. And the electro-optic property of vertically aligned single domain cells has been investigated.

  • PDF

Crystallization and In-plane Alignment Behavior of Pb(Zr, Ti)$O_3$ Films

  • Hwang, Kyu-Seog;Kim, Byung-Hoon
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.191-194
    • /
    • 1997
  • Epitaxial Pb(Zr, Ti)O3(PZT) thin films were prepared on MgO(100) substrates by dipping-pyrolysis (DP) process using metal naphthenates as starting materials, and effects of pyrolysis and final heat-treatment conditions on the film's orientation were investigated. Solid-state epitaxial growth of PZT proceeds at lower temperature around 650℃ from the precursor pyrolyzed at 350 and 500℃. The in-plane alignment of the PZT films depends not only on the final heat-treatment temperature but on the pyrolysis conditions; the films, pyrolyzed at a higher temperature for a short time, i.e., at 500℃ for 10 min, exhibited stronger orientation after the same final heat treatment at 650°∼750℃. The PZT films with the strongest orientation were prepared by pyrolysis under the above conditions followed by final heat treatment at 750℃.

  • PDF

평면배향된 a-축 수직 $YBa_2Cu_3O_{7-x}$ 고온초전도 박막의 제작 (Fabrication of the in-plane Aligned a-Axis Oriented $YBa_2Cu_3O_{7-x}$ Thin Films)

  • 성건용;서정대
    • 한국세라믹학회지
    • /
    • 제33권3호
    • /
    • pp.313-320
    • /
    • 1996
  • We have fabricated an in-plane aligned a-axis oriented YBa2Cu3O7-x (a-YBCO) thin film on a LaSrGaO4(100) substrate with a PrBa2Cu3O7-x(PBCO) template layer by two step plused laser deposition using 308 nm XeCl excimer laser. A YBCO layer and PBCO layer grown at low temperatures were used as template layers. We have investigated the effect of the deposition temperature of template layers on the superconducting and struc-tural properties of in-plane aligned a-YBCO thin films. An optimal deposition temperature of the PBCO template layers was 630. In-plane aligned a-YBCO thin films showed an anisotropy ratio in resistivity of 11.5 and a zero resistance temperature of 88 K.

  • PDF

후족부 관상면 배열 영상에 대한 고안 (Introduction of Hindfoot Coronal Alignment View)

  • 문일봉;전주섭;윤강철;최남길;김승국
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.225-228
    • /
    • 2006
  • 목 적: 후족부의 병리학적 상태의 치료와 평가를 위해서는 관상면에서 종골과 경골이 연관된 배열상태의 정확한 평가가 필수적이다. 이전의 방사선학적 검사인 발과 발목의 전후방향, 측방향, 사방향 촬영과 종골 축방향 촬영 등의 X-선 촬영상은 관상면에서 종골과 경골이 연관된 배열상태를 증명하지 못했다. 이에 본 연구에서는 후족부 관상면 배열영상(hindfoot coronal alignment view)을 새롭게 소개하고자 한다. 검사방법 : 1) 양쪽 발을 지탱할 수 있는 방사선투과성의 스탠드형 보조기구를 제작한다. 2) 양측 발은 weight-bearing position이 되게 한다. 3) 각각의 발의 위치는 발의 종축이 보조기구 판과 수직이 되도록 자세를 유지한다. 4) silhouette tracing: 발뒷꿈치 outline과 둘째 발가락이 일직선상으로 지나도록 위치시킨다. 5) 중심 X-선: 발바닥 쪽을 향해 약 $15{\sim}20^{\circ}의 각도로 종골의 뒷쪽을 향해 입사한다. 결 과 : 1) 경골 축과 종골의 내측, 외측 결절의 영상이 함께 표출된다. 2) 종골이 회전되지 않아야 한다. 3) 거퇴관절강(talotibial joint space)이 함께 나타나야 한다. 결 론: CT나 MRI 영상에서도 관상면에서 후족부의 배열상태를 증명할 수 있지만, 환자의 체중이 주어지지 않기 때문에 발의 임상적인 증상을 보여주기에는 충분하지 못했다. 하지만 후족부 관상면 배열영상은 후족부의 inversion, eversion의 자세변화를 보여주고, 경골 원위부와 종골의 varus, valgus deformity의 치료를 위한 평가 자료로 좋은 검사방법이며, 비교적 자연스럽고 편안한 자세로 환자에게 큰 도움을 줄 것으로 사료된다.

  • PDF