• Title/Summary/Keyword: In-pile Data

Search Result 314, Processing Time 0.023 seconds

Study(II) on Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Improvement Measures of Current Design Method by Analyzing Current Design Data for Prebored PHC Piles - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(II) - 설계 사례 분석을 통한 매입 PHC말뚝의 설계 개선 방향 -)

  • Yea, Geu Guwen;Yun, Dae Hee;Yun, Do Kyun;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.8
    • /
    • pp.31-42
    • /
    • 2019
  • A total of 73 pile design data for prebored PHC piles was analyzed to study the current design method. Based on the design data, a ratio of skin friction to total capacity from the pile design data was about 20~53%. Such low ratio of skin friction to total capacity tends to underestimate skin friction. Considering this tendency, the current design method should be improved. Also, an average design efficiency of PHC pile capacity was 70% and an average design efficiency for bearing capacity of soil or weathered rock was 80%, which shows slightly higher value than the former. This is probably due to the fact that the allowable bearing capacity is estimated to be equal to or slightly higher than the design load. Hence, the allowable bearing capacity should be estimated to be higher than the long-term allowable compressive force of the PHC pile. In the current design method, skin friction is calculated to be about 2.2 times lower than end bearing. The current design method for prebored PHC piles applied foreign design methods without any verification of applicability to the domestic soil or rock condition. Therefore, the current design method for prebored PHC piles should be improved.

A simple approach for quality evaluation of non-slender, cast-in-place piles

  • Zhang, Ray Ruichong
    • Smart Structures and Systems
    • /
    • v.4 no.1
    • /
    • pp.1-17
    • /
    • 2008
  • This study proposes a conceptual framework of in-situ vibration tests and analyses for quality appraisal of non-slender, cast-in-place piles with irregular cross-section configuration. It evaluates a frequency index from vibration recordings to a series of impulse loadings that is related to total soil-resistance forces around a pile, so as to assess if the pile achieves the design requirement in terms of bearing capacity. In particular, in-situ pile-vibration tests in sequential are carried out, in which dropping a weight from different heights generates series impulse loadings with low-to-high amplitudes. The high-amplitude impulse is designed in way that the load will generate equivalent static load that is equal to or larger than the designed bearing capacity of the pile. This study then uses empirical mode decomposition and Hilbert spectral analysis for processing the nonstationary, short-period recordings, so as to single out with accuracy the frequency index. Comparison of the frequency indices identified from the recordings to the series loadings with the design-based one would tell if the total soil resistance force remains linear or nonlinear and subsequently for the quality appraisal of the pile. As an example, this study investigates six data sets collected from the in-situ tests of two piles in Taipu water pump project, Jiangshu Province of China. It concludes that the two piles have the actual axial load capacity higher than the designed bearing capacity. The true bearing capacity of the piles under investigation can be estimated with accuracy if the amplitude of impact loadings is further increased and the analyses are calibrated with the static testing results.

Field investigation and numerical study of ground movement due to pipe pile wall installation in reclaimed land

  • Hu Lu;Rui-Wang Yu;Chao Shi;Wei-Wei Pei
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.397-408
    • /
    • 2023
  • Pipe pile walls are commonly used as retaining structures for excavation projects, particularly in densely populated coastal cities such as Hong Kong. Pipe pile walls are preferred in reclaimed land due to their cost-effectiveness and convenience for installation. However, the pre-bored piling techniques used to install pipe piles can cause significant ground disturbance, posing risks to nearby sensitive structures. This study reports a well-documented case history in a reclamation site, and it was found that pipe piling could induce ground settlement of up to 100 mm. Statutory design submissions in Hong Kong typically specify a ground settlement alarm level of 10 mm, which is significantly lower than the actual settlement observed in this study. In addition, lateral soil movement of approximately 70 mm was detected in the marine deposit. The lateral soil displacement in the marine deposit was found to be up to 3.4 and 3.1 times that of sand fill and CDG, respectively, mainly due to the relatively low stiffness of the marine deposit. Based on the monitoring data and site-investigation data, a 3D numerical analysis was established to back-analyze soil movements due to the installation of the pipe pile wall. The comparison between measured and computed results indicates that the equivalent ground loss ratio is 20%, 40%, and 20% for the fill, marine deposit and CDG, respectively. The maximum ground settlement increases with an increase in the ground loss ratio of the marine deposit, whereas the associated influence radius remains stationary at 1.2 times the pipe pile wall depth (H). The maximum ground settlement increases rapidly when the thickness of marine deposit is less than 0.32H, particularly for the ground loss ratio of larger than 40%. This study provides new insights into the pipe piling construction in reclamation sites.

Nonlinear numerical analyses of a pile-soil system under sinusoidal bedrock loadings verifying centrifuge model test results

  • Kim, Yong-Seok;Choi, Jung-In
    • Geomechanics and Engineering
    • /
    • v.12 no.2
    • /
    • pp.239-255
    • /
    • 2017
  • Various centrifuge model tests on the pile foundations were performed to investigate fundamental characteristics of a pile-soil-foundation system recently, but it is hard to find numerical analysis results of a pile foundation system considering the nonlinear behavior of soil layers due to the dynamic excitations. Numerical analyses for a pile-soil system were carried out to verify the experimental results of centrifuge model tests. Centrifuge model tests were performed at the laboratory applying 1.5 Hz sinusoidal base input motions, and nonlinear numerical analyses were performed utilizing a finite element program of P3DASS in the frequency domain and applying the same input motions with the intensities of 0.05 g~0.38 g. Nonlinear soil properties of soil elements were defined by Ramberg-Osgood soil model for the nonlinear dynamic analyses. Nonlinear numerical analyses with the P3DASS program were helpful to predict the trend of experimental responses of a centrifuge model efficiently, even though there were some difficulties in processing analytical results and to find out unintended deficits in measured experimental data. Also nonlinear soil properties of elements in the system can be estimated adequately using an analytical program to compare them with experimental results.

A Study on Prediction of the Coefficient of Horizontal Subgrade Reaction for Pile Using Lateral Pile Loading Test Results (수평재하시험 결과를 이용한 말뚝의 수평방향 지반반력계수 예측에 관한 연구)

  • Chun, Byung-Sik;Seo, Deok-Dong;Lee, Young-Jae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.2
    • /
    • pp.15-24
    • /
    • 2006
  • In this paper, the Coefficient of Subgrade Reaction was analyzed from the data which were the results of lateral pile loading tests and pressuremeter tests on construction sites. The prediction method with N-value was compared with lateral pile loading tests and the results of lateral pile loading tests were compared with the prediction method considering diameter of a pile. Also, the results of lateral pressuremeter tests were compared with those of lateral pile loading tests. As a result, consideration for a diameter and lateral deformation of a pile was needed when the coefficient of horizontal subgrade reaction is presumed. Therefore, a formula which is taking into account the allowable deformation of a pile was suggested from lateral pressuremeter tests in this study.

  • PDF

Estimation of Ultimate Bearing Capacity of SCP and GCP Reinforced Clay for Laboratory Load Test Data (SCP 및 GCP 개량 점성토지반의 실내재하시험에 대한 극한지지력 산정 방법 개발)

  • Bong, Tae-Ho;Kim, Byoung-Il;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.37-47
    • /
    • 2018
  • In this study, 34 laboratory load test data were collected, and analyzed to propose the equations for predicting ultimate bearing capacity of sand compaction pile (SCP) and gravel compaction pile (GCP) reinforced clay. The collected data were compared with the ultimate bearing capacity estimated by existing theoretical equations, and the prediction accuracy of the existing theoretical equations was identified. Also, multiple regression analysis was performed to predict the ultimate bearing capacity, and the most efficient number and type of input variables were selected through error evaluation by leave-one-out cross validation. Finally, the multiple regression equations for estimating the ultimate bearing capacity of laboratory load test for SCP and GCP were proposed, and their performance was evaluated.

Experimental and numerical study on performance of long-short combined retaining piles

  • Xu, Chang J.;Ding, Hai B.;Luo, Wen J.;Tong, Li H.;Chen, Qing S.;Deng, Jian L.
    • Geomechanics and Engineering
    • /
    • v.20 no.3
    • /
    • pp.255-265
    • /
    • 2020
  • Laboratory tests are conducted to investigate the performance of retaining system with different combinations of long-short piles. Numerical analysis implemented using ABAQUS are verified by comparing numerical results with measured data. By performing numerical studies, the horizontal displacement of piles, heave of excavation bottom and bending moment of pile for various pile system with different pile lengths are investigated. Results show that long piles share higher bending moments than short piles. The increase in the number of short piles leads to a slight increase in the heave at excavation bottom for long-short pile retaining system. Retaining system with different long and short pile combinations have greater effects on the horizontal displacement of pile above the excavation bottom, compared to its counterparts below excavation bottom. For a given length of long pile, the bending moment and displacement of piles increase with the decrease in length of short piles, while the increasing rate of maximum moment of retaining pile system is insignificant. Results highlight that a reliable and economical pile retaining system can be designed by optimizing the number and length of short piles, provided that the working performance of retaining structures above excavation bottom meets the design requirement in practice.

Determination of True Resistance from Load Transfer Test Performed on a PHC Pile (PHC 말뚝의 하중전이실험을 통한 참 지지력의 산정)

  • Kim, Sung-Ryul;Chung, Sung-Gyo;Dzung, N.T.
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.11
    • /
    • pp.113-122
    • /
    • 2006
  • Although a number of static pile load tests have been performed in this country, re-consideration on the interpretation and loading method is needed, because of their less usefulness in practice. For this study, a static loading testing was performed for a long instrumented PHC pile, which was installed in sand layer overlying thick soft clay. The shaft resistance of the pile had been monitored for a long time after installation, and then the static load testing was performed by the quick load test, unlike the recent Korean practice. Using the measured data, the elastic modulus of pile, residual stress and true resistance on the pile were determined. In the event, it was found that the residual stress on the pile, which remained prior to the static loading, significantly affects the shaft and toe resistances. Also, it was realized that the setup effect for the long pile is significant.

Development of Non-Contact Penetration Measuring Device for Pile Driving Workers (항타 시공 작업자를 위한 비접촉식 관입량 측정기 개발)

  • Kim, J.K.;Kong, Y.K.;Choi, K.H.;Cho, M.U.;Kim, S.Y.;Kim, M.J.;Lee, J.H.;Park, Chae Won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.58-63
    • /
    • 2020
  • At the construction site of the driving site, the pile rebound and penetration measurements are performed manually to determine the end point of the driving operation, thereby causing the measurer to be exposed to a death accident. In this study, in order to eliminate the risk of this work, a non-contact penetration measuring device was developed and usability evaluation was conducted. The penetration measuring device is manufactured based on the ultrasonic sensor, and can be combined with the pile to deliver the data in real time, and the delivered data can be output in real time on the portable PC and the final penetration can be calculated. Usability evaluation on the device was conducted by comparison with manual work. Usability evaluation was largely evaluated on measured values, subjective comfort, and body parts comfort. The result of the measured value tended to overestimate the value measured manually by the measuring device, which is similar to the previous research. In terms of subjective comfort and body part comfort, overall satisfaction was higher than the manual method when using the measuring device. Taken together, these results indicate that it is possible to use the rudder measuring device in place of manual work in the construction site, and it is judged that the worker's comfort is greatly increased by using the measuring machine. The results of this study suggest that the use of non-contact measuring device in the field can be used as basic data to support them.

Proposed Deterioration-induced Axial Stiffness of Existing Piles in Vertical Extension Structures (수직증축 공동주택 하부 기존말뚝의 열화를 고려한 축강성 제안)

  • Jeong, Sang-Seom;Kim, Do-Hyun;Cho, Hyun-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.25-33
    • /
    • 2019
  • In this study, the axial stiffness of existing piles (Kve) of vertical extension remodeled building was quantified through theoretical and experimental approaches. Theoretically induced upper and lower boundary of the pile axial stiffness was estimated by using the formula proposed by Randolph and Wroth (1978), which can estimate the axial stiffness of rigid and flexible pile subjected under soil confinement. In addition, 38 cases of field measurement data on deteriorated piles with various diameters constructed in the period between 1995 - 1997 were taken in to account by overlapping the field data with the theoretical boundary of the axial stiffness. Through this the maximum axial stiffness of existing pile due to deterioration and long service time was presented for various slenderness ratio (L/D), which can be used in estimating the necessary axial stiffness of reinforcing piles(Kvr) for the vertical extension remodeling. The lower 95% value of the estimated axial stiffness of existing pile will be induced through statistical processing.