• 제목/요약/키워드: In-line monitoring

검색결과 1,355건 처리시간 0.032초

Process Monitoring in Laser Beam Cutting by Photo Diode (레이저 절단에서 광소자를 이용한 가공공정 모니터링)

  • Chang, Ook-Jin;Kim, Bong-chae;Kim, Jae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제13권12호
    • /
    • pp.30-37
    • /
    • 1996
  • On-line process control equipment for CO$_{2}$ laser cutting is not available for industrial applications. The major part of the industrial laser cutting machines are adjusted off-line by highly educated engineers. The quality inspection of the sample is visual and referred to different quality scales. Due to the lack of automation the potential laser users hesitate to implement the cutting method. The first step toward an automation of the process is the development of a process monitoring system and the research is cincentrated on the area of on-line quality monitoring during CO$_{2}$ laser cutting. The method is based on the detection of the emitted light from the cutting front by photo diode. The developed monitoring system consists of the OP Amplifier, A/D convertor, power supply and PC. The signal from the photo diode has been undertaken from Fourier analysis and statistical analysis with real time. The photograph of striation pattern was taken by metallurgical microscope. As a result, it is possible to predict the striation pattern according to the beam traveling speed.

  • PDF

On-line identification of the toxicological substance in the water system using Baysian technique (베이지언 기법을 이용한 수계 내의 독성물질 판단)

  • Jung, Ha Kyu;Jung, Jong Hyuk;Lee, Hyun Wook;Kwon, Won Tae;Kim, Sang Gil;Jeon, Sook Lye
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제22권1호
    • /
    • pp.73-78
    • /
    • 2008
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and to monitor the water pollution. The monitoring system, however, has not been used to determine what kind of the toxicological substance is in the water. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is made to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.

On-line Measurement of Buffer Capacity of a Fermentation medium and Estimation of Organic Aicd Production (발효배지의 완충용량의 온라인 측정 및 유기산 생산 추정)

  • Hur, Won;Jung, Yoon-Keun
    • KSBB Journal
    • /
    • 제13권4호
    • /
    • pp.461-467
    • /
    • 1998
  • A fermentation system was supplemented with a device for the measurement of the durations of alkali pump feeding for automatic pH control and an A/D convertor for precise monitoring of pH value by computer. A software program was developed to measure buffer capacities from the pH signal and the pH control signal during fermentation. By measuring the buffer capacity on-line, levels of acetic acid were estimated by a software sensor using pH signal in a fermentation process of E.coli growing in a minimal medium. The measured values of acetic acid showed correlation to those of estimated by the software sensor. Lacitic acid production was also successfully estimated by the values of buffer capacities measured on-line.

  • PDF

Tool wear monitoring of end mill in slot machining of titanium alloy (티타늄 합금의 슬롯가공에서 엔드밀 공구마멸 감시)

  • 하건호;구세진;김정석;양순철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 1995
  • A acoustic emission (AE) sensor has been used to monitor tool were during milling process. The relation between tool wear and AE RMS (Root mean Square) signal was investigated experimentally. A avaliable monitoring index for monitoring toolwear was newly extracted form AE RMS. And on-line monitoring program was developed. The proposed monitoring system has verified experimentally by roughing end milling titanium alloy with TIN coated HSS tool.

  • PDF

Analysis of the Dielectric Sensor for Cure Monitoring of Composite Materials (복합재료 경화모니터링용 유전센서의 해석)

  • 김진수;이대길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권7호
    • /
    • pp.1563-1572
    • /
    • 1995
  • The on-line cure monitoring during the cure process of fiber reinforced resin matrix composite material is important for the better quality and productivity. Among several cure monitoring methods, the dielectrometry that uses electrodes as its sensor is known to be the most promising method. In this study, the sensitivity of the dielectric sensor for the on-line cure monitoring was analyzed by finite element method and compared to the experimental results. Using the analytical results, the equation for the capacitance of the sensor was derived. Also, the optimal sensor design method was suggested after analyzing several different sensor shapes.

A study on field test of diagnostic Monitoring System for Power Transformers (전력용 변압기 예방진단 시스템의 실 계통 적용 연구)

  • Kim, Y.H.;Lee, C.R.;HwangBo, S.W.;Shin, Y.T.;Park, G.C.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

On-line Gamma Monitoring System for Environmental Radiation Measurement around KAERI-site (KAERI 부지 주변의 환경선량 측정을 위한 온라인 감마선량 감시시스템)

  • Lee, Chang-Woo;Park, Doo-Won;Lee, Won-Yun;Choi, Yong-Ho;Hong, Kwang-Hee;Kim, Sam-Rang;Lee, Hyun-Duk;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제19권2호
    • /
    • pp.147-156
    • /
    • 1994
  • On-line gamma monitoring system around KAERI-site was set up to monitor the radiation fluctuations in environment. Data on gamma exposure rates measured by the ionication chamber in the monitoring posts are transmitted to a computer of central control station with. radio telemetry transmission modem and monitored in real time. Radio telemetry transmission system is economical and reliable on handling and storing of data. This monitroing system can triger an early warning system in the event of abnormal radiation levels.

  • PDF

On-line identification of the toxicological substance in the water system using Baysian technique (베이지언 기법을 이용한 수계 내의 독성물질 판단)

  • Jung, Ha-Kyu;Jung, Jong-Hyuk;Lee, Hyun-Wook;Kwon, Won-Tae;Kim, Sang-Gil;Jeon, Sook-Lye
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3122-3127
    • /
    • 2007
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and monitor the water pollution. The monitoring system, however, could determine whether the examined water was safe or not. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is given to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.

  • PDF

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Realization of a Web based Remote Monitoring Server for SMD In Line System (SMD 조립 설비의 웹기반 원격 관리 서버 구축)

  • Lim, S. J.;Park, K. T.;Lyou, J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • A Remote Monitoring Server(RMS) server which uses Internet and World Wide Web is constructed for SMD in-line system. Hardware base consists of server computer, virtual SMD in-line system and other computers. Software includes assignment of server, RDBMS and various modules in server home page. Web browser provide production quantity, bad PCB quantity, error number and error message in virtual SMD module, user information in setup module, detailed error information in fault diagnosis module, fault history in fault history module and customer information in customer service management module. These functions of the RMS helps a decrease of non-operation time and a service response as fast as possible.

  • PDF