• Title/Summary/Keyword: In-line Orifice

검색결과 59건 처리시간 0.025초

고압 대유량 측정설비의 유량컴퓨터 개발 (Development of Flow Computer for High Flow Rate Natural Gas Metering Facility)

  • 하영철;허재영;이철구;이강진;안승희;정종태
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.272-277
    • /
    • 2000
  • The flow computer named Kogas I has been developed for measuring high flow natural gas. The developed model is classified as individual type in order that one flow computer covers one metering line. Nearly all of the functions are adopted similar to the foreign, commercial flow computer, and the merit of this flow computer is being able to apply for both orifice and turbine meters. The performance has been verified through the field test for 2 years.

  • PDF

상악(上顎) 제이대구치(第二大臼齒) 치수저(齒髓底)의 해부학적(解剖學的) 고찰(考察) (A STUDY ON THE ANATOMY OF THE PULP CHAMBER FLOOR OF THE PERMANENT MAXILLARY SECOND MOLAR)

  • 권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.53-57
    • /
    • 1981
  • A total of 130 extracted human maxillary second molars were used to study the configuration of the floor of the pulp chamber. The specimens were ground and the pulp chamber was examined with a magnifier and explored with sharp explorer. The study showed the shape of the pulp chamber, number of root canals, and the type of canal orifice. The results were as follows; 1. In so far as observing the shape of the pulp chamber of the teeth, 16.9% of the teeth were quadrilateral, 70.0% were triangle and 13.1% were ovoid shape. 2. 13.1% of the specimens have 4 root canal orifices. 73.9% have 3 root canal orifices, 11.5% have 2 root canal orifices and 1.5% have single orifice. 3. 13.1% of the specimens have 2 mesio-buccal canal orifices and among the teeth those have 3 canals, 20.8% show 'Y' shape, 29.1% show straight line and 23.8% show obtuse triangle shape.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

포펫트밸브내에서의 캐비테이션에 관한 FLUENT 모델링 (FLUENT MODELLING OF CAVITATION IN POPPET VALVES)

  • Chung-Do, Nam
    • 해양환경안전학회지
    • /
    • 제5권2호
    • /
    • pp.113-123
    • /
    • 1999
  • The aim of this paper was to expand on work already carried out on the modelling of the flow through a poppet valve using CFD software FLUENT V4.22. Several different models were run on FLUENT for various lifts of the poppet cone and various back pressures. The results for pressure and velocity obtained were interpreted. The results revealed the presence of cavitation downstream of the orifice around the cone tip, and the presence of a high velocity jet stream along the centre line. These results confirm what has been found to happen in practice.

  • PDF

EFD를 이용한 곡관부 배관계에 발생하는 유체진동 해석 (The Analysis of Piping Vibration by EFD)

  • 배춘희;조철환;양경현;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1070-1072
    • /
    • 2003
  • In this paper, Firstly, it is shown that the high vibration source of piping system is the pulsation transmission of pipe line element ,such as, orifice plate, valves and the control valve is a broad band source and the branch wall and the cavity have vortex frequency Secondly, in order to decrese the turbulence vibration of piping system, the practical analysis of piping flow by EFD have been developed and its effectiveness is investigated as applying it at piping system practically.

  • PDF

원자력발전소 유출계통의 과도현상에 대한 연구 (A Study on Hydraulic Transients of Letdown System of Nuclear Power Plant)

  • 김민;정장규;김은기;노태선;이성노;유성연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.493-498
    • /
    • 2002
  • The letdown system of pressurized water reactor (PWR) nuclear fewer plants had experienced instabilities in letdown system due to unacceptable flow characteristics of control valves. The Korean Standard Nuclear Power Plants (KSNPs) have three flow paths in parallel for letdown new control. Each flow path consists of two offices and one isolation valve. This study evaluates the effect of orifice arrangement and valve stroke time of letdown isolation valve on the system transients because sudden flow changes due to valve actuation can generate high pressure peaks in letdown line. A pressure transient analysis has been preformed to evaluate the impact of dynamic transients. This analysis uses MMS which is a simulation code developed by EPRI based on the method of characteristics. The result shows that the pressure peak is reduced in the continuous arrangement but negligible. Additionally, it shows that the stroke time of linear type flog valve greater than 15 seconds can give more stable performance.

  • PDF

급성실혈시의 식도운동 (The Motility of Esophagus in Acute Hemorrhage)

  • 박순일;신동훈
    • The Korean Journal of Physiology
    • /
    • 제6권2호
    • /
    • pp.39-48
    • /
    • 1972
  • Two polyethylene tubes were inserted into the esophagus of anesthetized rabbit in order to record the fluctuation of the intraluminal pressure through the orifices located near the tips of the tubes. The orifice of the first tube was 10 cm apart from the incisor of the rabbit and the orifice of the second tube was 5 cm below that of the first one. The tubes were filled with saline solution running at various rates ranging from 1.5 ml/min. to 4.2 ml/min. The tubes were connected to the pressure transducers and the electrical signals were recorded by the physiograph. When the peristaltic wave approached to the orifice a rise in the pressure was recorded, returning to the base line when the portion of the orifice was quiescent. The frequency of the peristaltic motion and the velocity of the wave were studied in connection with the flow rate of saline solution through the tubes and in the case of massive acute hemorrhage. The results obtained were as follows: 1. There was reflux of fluid induced during the procedure of the experiment. This outwrad flow through the pharynx seemed to elicite swallowing reflexes. Accordingly, the frequency of peristalsis of the esophagus was largely dependent on the flow rate of the fluid through the inserted tubes. By the flow rate of 1.5 ml/min., 2.5 ml/min., or 4.2 ml/min., the frequencies of the peristalsis were revealed to be $8.6{\pm}3.6/10min.,\;14.5{\pm}4.8/10min.\;or\;21.1{\pm}6.3/10min.,$ respectively. The velocity of peristalsis also coincided with the enhanced motility of the esophagus, showing $6.6{\pm}1.5\;cm/sec.,\;8.9{\pm}3.9\;cm/sec.,\;or\;12.4{\pm}4.6\;cm/sec.,$ respectively. 2. By acute hemorrhage, amounting to 2% of the body weight, the frequency of the peristalsis increased to twofold of the control and the propagation velocity also increased by 52 percent. 3. Retransfusion of the shed blood resulted in divergent responses. In some cases there were noticable ameliorations of the effects brought by acute hemorrhage, and in the others there were still increasing tendenies of the motility after the transfusion. 4. Some speculation was made about the possibility of a kind of relationship between the irreversibility of the hemorrhagic shock and the absence of responses by transfusion. 5. The peristalsis persisted even after complete disconnection at the midportion of the esophagus, reaffirming the view of a central regulation of the spatiotemporally coordinated motility, peristalsis.

  • PDF

동력분무기용(動力噴霧機用) 삼분두(三噴頭)의 살포도(撒布度) 개선(改善)에 관(關)한 연구(硏究) (Study on the Improvement of Distribution Pattern in the Triple Nozzle System)

  • 홍성화;이상우
    • 농업과학연구
    • /
    • 제11권2호
    • /
    • pp.284-294
    • /
    • 1984
  • 동력분무기용(動力噴霧機用) 3분두(噴頭) 분공(噴孔)의 크기, 살포각도(撒布角度) 및 와실(渦室)의 간격을 변화(變化)시키면서 최대(最大) 분무유효거리(噴霧有效距離)의 구명(究明)과 살포도(撒布度)의 개선(改善)을 위(爲)한 분두배열(噴頭配列) 방법(方法)의 분석결과(分析結果)는 다음과 같다. 1. 분공(噴孔) 직경(直徑)이 커짐에 따라 분무량(噴霧量)은 증가(增加)하였고 1번구(番口)는 2차(次) 곡선(曲線)으로 II번구(番口), III번구(番口)는 1차(次) 함수관계(關係)를 나타냈다. 2. 최대(最大) 유효거리(有效距離)는 살포각도(撒布角度)가 $15^{\circ}$일때 최대(最大) 값을 나타냈고 분공(噴孔)의 크기가 3.0mm일때 약17m, 2.5mm 및 2.0mm 일때 각각 약 14m, 약 13m로 나타났다. 3. 살포도(撒布度)의 균등개선(均等改善)을 위(爲)한 분두배열(噴頭配列)(表 6참조(參照))은 I번구(番口)의 분공(噴孔)크기에 따라 다르지만 균등계수(均等係數)는 약 6%정도(程度) 개선(改善)시킬 수 있었다. 4. 살포거리(撒布距離) 6m의 최저(最低) 살포량(撒布量)을 II번구(番口)의 와실(渦室) 간격 조절(調節)로서 개선(改善)시킬 수 있었다.

  • PDF

배수갑문(排水閘門)의 관리(管理) 및 배제유량(排除流量)에 관(關)한 연구(硏究) (A Study on the Management and the Discharge of the Sluice Gates)

  • 김태철;이덕주;한영수
    • 농업과학연구
    • /
    • 제17권2호
    • /
    • pp.102-114
    • /
    • 1990
  • 본 연구는 배수갑문의 관리 및 운용 상황을 알기 위하여 삽교호를 모형으로 분석하였으며, 수리모형실험을 통하여 농지개량사업 계획설계기준의 제안식을 검토한 결과는 다음과 같다. 1. 삽교호의 9개년간의 평균 개문(開門)높이 4.13m이었고, 평균 조작연수(操作連數)는 4.04연(連), 연(年)평균 조작회수는 67회(回)이었으며, 배제시간은 연(年)평균 192시간 32분, 1회(回) 평균 2시간 53분 이었다. 2. 삽교호를 통하여 공급한 용수는 연(年)평균 8,815만톤으로 삽교호 유효저수량의 약 1.4배이며, 월별 최대 양수월(揚水月)인 5월의 양수량은 평균 2,956 만톤/년으로 유효저수량의 약 1/2을 양수하였다. 3. 설계기준에 제시된 오리피스 공식은 수중오리피스에서 완전오리피스 형태로 바뀌는 경계영역에서 급격한 배제량의 단절이 나타났으며, 이는 실제 수리현상과 다르므로 개선되어야 한다. 4. 오리피스의 공식은 수중과 완전으로 구분하여 사용하고 있으나, 내 외수위 및 수문 개방도를 고려하여 유량계수를 적용하면 수중 및 완전 오리피스의 모든 경우에도 $q=C{\cdot}W\sqrt{2gH_1}$의 공식을 적용할 수 있다.

  • PDF

축방향 압력섭동에 의해 발생되는 저주파 수력학적 교란이 단일 스월 인젝터에 미치는 영향 분석 (Spray Characteristics of Simplex Swirl Injector with Low Hydrodynamic Disturbance Generated by Pressure Fluctuation in Feed Line)

  • 길태옥;김성혁;김현성;윤영빈
    • 한국분무공학회지
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2007
  • The low frequency combustion instability phenomena generated by pressure drop oscillation such as propellant shake in feed line are studied. To generate the flowrate oscillation by the pressure pulsation up to 400Hz without flow discontinuities and cavitations, a hydrodynamic mechanical pulsator of rotating disk type was produced. Injection pressure conditions are 5, 7 and 9 bar and pressure fluctuation frequency conditions are 0, 4, 6 and 8 Hz. When the injection pressure was oscillated by a mechanical pulsator, the spray shape was pulsated regularly. During the pulsated state of the spray with a mechanical pulsator, the spray characteristics, such as spray angle and liquid film thickness in orifice exit, were measured and compared with those in steady state without a mechanical pulsator. Though the mean injection pressure was fixed in the steady and fluctuating state, there were some differences in all measured values, i.e. liquid film thickness and spray cone angle, between both states.

  • PDF