• Title/Summary/Keyword: In-line Mixer

Search Result 63, Processing Time 0.026 seconds

An MMIC Doubly Balanced Resistive Mixer with a Compact IF Balun (소형 IF 발룬이 내장된 MMIC 이중 평형 저항성 혼합기)

  • Jeong, Jin-Cheol;Yom, In-Bok;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1350-1359
    • /
    • 2008
  • This paper presents a wideband doubly balanced resistive mixer fabricated using $0.5{\mu}m$ GaAs p-HEMT process. Three baluns are employed in the mixer. LO and RF baluns operating over an 8 to 20 GHz range were implemented with Marchand baluns. In order to reduce chip size, the Marchand baluns were realized by the meandering multicoupled line and inductor lines were inserted to compensate for the meandering effect. IF balun was implemented through a DC-coupled differential amplifier. The size of IF balun is $0.3{\times}0.5\;mm^2$ and the measured amplitude and phase unbalances were less than 1 dB and $5^{\circ}$, respectively from DC to 7 GHz. The mixer is $1.7{\times}1.8\;mm^2$ in size, has a conversion loss of 5 to 11 dB, and an output third order intercept(OIP3) of +10 to +15 dBm at 16 dBm LO power for the operating bandwidth.

Design of 2nd-harmonic Quadrature Mixer for Ultra Wideband(UWB) Systems (2차 고조파를 이용한 UWB 시스템용 쿼드러쳐 혼합기 설계)

  • Jung, Goo-Young;Lim, Jong-Hyuk;Choi, Byung-Hyun;Yun, Tae-Yeoul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1156-1163
    • /
    • 2006
  • This paper presents an ultra wideband(UWB) direct conversion mixer for IEEE 802.15.3a applications with simulation and measurement results. Since the direct conversion mixing causes dc-offset and even-order distortion, the proposed mixer adopts an anti-parallel diode pairs(APDPs) to solve these problems. The proposed mixer consists of an in-phase wilkinson power divider over $3.1{\sim}4.8GHz$, a wideband $45^{\circ}$ power divider over $1.5{\sim}2.4GHz$, and miniatured band pass filters(BPFs) for RF-LO isolations. The conversion loss is optimized with impedance matchings between APDPs and wideband components. The measured mixer shows the conversion loss of 13.5 dB, input third-order intercept-point($IIP_3$) of 7 dBm, and 1-dB gam compression point($P_{1dB}$) of -4 dBm. Quadrature(I/Q) outputs have the magnitude difference of about 1 dB and phase difference of ${\pm}3^{\circ}$.

A CRYOGENIC TWO MILLIMETER RECEIVER SYSTEM

  • Lee, Chang-Hoon;Han, Seog-Tae;Park, Yong-Sun
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.232-249
    • /
    • 1994
  • Since we finished the purchase of the cooled Schottky diode mixer receiver made by Radiometer Physics Co. for the 120-170GHz range in October 1991, we have not prepared the PPL hardware and software for this receiver and the ellipsolidal mirror for beam guiding. After these problems were solved, this receiver was installed at the 14m telescope in late December 1993, and used for the confirmation of a spectral line detection and the measurement of the beam efficiency. The beam efficiency is about 36% at 146 GHz.

  • PDF

Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent (하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용)

  • Lee, Chul-Woo;Shon, Jung-Ki;Shon, In-Shik;Han, Seung-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.

Design and Fabrication of a Broadband RF Module for 2.4GHz Band Applications (2.4GHz 대역에서의 응용을 위한 광대역 RF모듈 설계 및 제작)

  • Yang Doo-Yeong;Kang Bong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.1-10
    • /
    • 2006
  • In this paper, a broadband RF module is designed and tested for 2.4GHz band applications. The RF module is composed of a low noise amplifier (LNA) with a three stage amplifier, a single ended gate mixer, matching circuits, a hairpin line band pass filter and a Chebyshev low pass filter to convert the radio frequency (RF) into the intermediate frequency (IF). The LNA has a high gain and stability, and the single ended gate mixer has a high conversion gain and wide dynamic range. In the analysis of the broadband RF module, the composite harmonic balance technique is used to analyze the operating characteristics of an RF module circuit. The RF module has a 55.2dB conversion gain with a 1.54dB low noise figure, $-120{\sim}-60dBm$ wide RF power dynamic range, -60dBm low harmonic spectrum and a good isolation factor among the RF, IF, and local oscillator (LO) ports.

  • PDF

Characterization of Microwave Active Circuits using the FDTD Method (FDTD를 이용한 마이크로파 능동 회로의 해석)

  • 황윤재;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.528-537
    • /
    • 2002
  • In this paper, the extended FDTD is used for the analysis of microwave circuits including active elements. Lumped elements such as R, L, C which are inserted into a microstrip line are analyzed with the FDTD lumped element modeling. Parasitic capacitance and inductance could be obtained using network modeling and so it is sure that FDTD lumped element modeling makes it possible to get more accurate data which include parasite components. Moreover, a balanced mixer using two diodes that are modeled by an extended FDTD is designed and the more exact characteristic of the mixer is acquired than in current circuit simulator.

A Study on the Data Transmission line of communication system (통신시스템의 데이터 전송선로에 대한 연구)

  • Kim Soke-Hwan;Lee Kyeu-jung;Hur Chang-wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.6
    • /
    • pp.1277-1281
    • /
    • 2005
  • FPGA has been widely used in communication system. In this paper, we made 10 layers PCB on protection of signal noise and data lose with FPGA. We analyzed about change of the data transmission speed and length according to input frequency. The length of transmission line from FPGA's output-pin to output-port on PCB board is 13cm and extended lengths for test are 30cm, 60cm and 10cm. We knew that data can be stably transmitted to 100Mbps at transmission line length of 30cm.

A System-in-Package (SiP) Integration of a 62GHz Transmitter for MM-wave Communication Terminals Applications

  • Lee, Young-Chul;Park, Chul-Soon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.182-188
    • /
    • 2004
  • We demonstrate a $2.1\;{\times}\;1.0\;{\times}\;0.1cm^3$ sized compact transmitter using LTCC System-in-Package (SiP) technology for 60GHz-band wireless communication applications. For low-attenuation characteristics and resonance suppression of the SiP, we have proposed and demonstrated a coplanar double wire-bond transition and novel CPW-to-stripline transition integrating air-cavities as well as novel air-cavities embedded CPW line. The fabricated transmitter achieves an output of 13dBm at a RF frequency of 62GHz, an IF frequency of 2.4GHz, and a LO frequency of 59.6GHz. The up-conversion gain is 11dB, while the LO signal is suppressed with the image rejection mixer below -21.4dBc, and the image and spurious signals are also suppressed below -31dBc.

A study of 10.5 GHz band Doppler radar for non-contact type hydrometer (비접촉식 유속계를 위한 10.5 GHz 대역 도플러 레이더에 대한 연구)

  • Kim, Jin-Su;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.139-144
    • /
    • 2009
  • A Doppler radar is a radar using the doppler effect of the returned echoes from targets to measure their radial velocity. To be more specific the microwave signal sent by the radar antenna's directional beam is reflected toward the radar and compared in frequency, up or down from the original signal, allowing for the direct and highly accurate measurement of target velocity component in the direction of the beam. In this paper, we designed the doppler radar composed of 10.5 GHz band DROs(Dielectric Resonator Oscillator), $90^{\circ}C$ branch line coupler, single balanced mixer and $4{\times}4$ array antenna of high gain, high directivity, for non-contact type hydrometer. Fabricated Doppler radar can detect slow moving objects.

  • PDF

Development of V-band Wireless Transceiver using MMIC Modules (MMIC 모듈을 이용한 V-band 무선 송수신 시스템의 구축)

  • Lee, Sang-Jin;An, Dan;Lee, Mun-Kyo;Go, Du-Hyun;Jin, Jin-Man;Kim, Sung-Chan;Kim, Sam-Dong;Park, Hyun-Chang;Park, Hyung-Moo;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.575-578
    • /
    • 2005
  • We report on a low-cost V-band wireless transceiver with no use of any local oscillator in the receiver block using a self-heterodyne architecture. V-band Microwave monolithic IC (MMIC) modules were developed to demonstrate the wireless transceiver using coplanar waveguide (CPW) and GaAs PHEMT technologies. The MMIC modules such as the MMIC low noise amplifier (LNA), medium power amplifier (MPA) and the up/down-mixer were installed in the transceiver system. To interface the MMIC chips with the component modules for the transceiver system, CPW-to-waveguide fin-line transition modules of WR-15 type were designed and fabricated. The fabricated LNA modules showed a $S_{21}$ gain of 8.4 dB and a noise figure of 5.6 dB at 58 GHz. The MPA modules exhibited a gain of 6.9 dB and a $P_1$ $_{dB}$ of 5.4 dBm at 58 GHz. The conversion losses of the up-mixer and the down-mixer module were 14.3 dB at a LO power of 15 dBm, and 19.7 dB at a LO power of 0 dBm, respectively. From the measurement of V-band wireless transceiver, a conversion gain of 0.2 dB and a P $_{1dB}$ of 5.2 dBm were obtained in the transmitter block. The receiver block showed a conversion gain of 2.1 dB and a P $_{1dB}$ of -18.6 dBm. The wireless transceiver system demonstrated a successful data transfer within a distance of 5 meters.

  • PDF