• Title/Summary/Keyword: In-direct Method

Search Result 7,524, Processing Time 0.033 seconds

Development of the Photogrammetric Method of Head Through 3-Dimensional Approach (3차원적 접근 방식을 통한 머리 부위 사진 측정법의 개발)

  • Kim, Woong;Nam, Yun-Ja;Kim, Min-Hyo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.7-13
    • /
    • 2005
  • We developed an accurate and reliable photogrammetric method available instead of the direct measurement method and the three-dimensional scanning method. Our research was restricted to a head on the body. Approaching three-dimensionally, we calibrated a distorted image of a photograph and got linear equations of camera beams. Then we assigned z values of landmarks in the head and obtained three-dimensional coordinates for each landmark putting those z values in linear equations of camera beams and finally could calculate measurement results from those three-dimensional coordinates. When we compared results obtained by a program, 'Venus Face Measurement(VFM)' that we had developed applying our method with results obtained by the direct measurement method, VFM showed very accurate and reliable results. In conclusion the photogrammetric method developed in this study was testified to an outstanding measurement method as a substitute for the direct measurement method and the three-dimensional scanning method.

Developing A Stochastical Dynamic Analysis Technique for Structures Using Direct Integration Methods (직접적분법과 확률론적 유한요소법을 이용한 구조물의 확률론적 동적 해석)

  • 이정재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.1
    • /
    • pp.54-62
    • /
    • 1994
  • The expanding technique of the Stochastic Finite Element Method(SFEM) is proposed in this paper for adapting direct integration methods in stochastical dynamic analysis of structures. Grafting the direct integration methods and the SFEM together, one can deal with nonlinear structures and nonstationary process problems without any restriction. The stochastical central diffrence and stochastic Houbolt methods are introduced to show the expanding technique, and their adaptabilities are discussed. Results computed by the proposed method (the Stochastic Finite Element Method in Dynamics: SFEMD) for two degree-of-free- dom system are compared with those obtained by Monte Carlo Simulation.

  • PDF

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

A Study on the One Bath Two Step Dyeing of Wool/Cationized Cotton Blends With Acid Dye/Direct Dye (양모/카티온화 면 혼방품의 산성염료/직접염료에 의한 1욕2단 염색에 관한 연구)

  • Sung, Woo-Kyung;Lee, Choon-Gil
    • Fashion & Textile Research Journal
    • /
    • v.3 no.2
    • /
    • pp.168-173
    • /
    • 2001
  • In order to overcome the disadvantage of the conventional two bath dyeing method of wool/cotton blends, it had prompted significant effort to the development of the one bath dyeing method which can accomplish savings in energy, water usage and time. To improve the dyeability of cotton toward direct dyes in a non-electrolytic and acidic dyebath, cotton component was pretreated with cationizing agent containing chlorohydrine group in aqueous solution of sodium hydroxide. This study was carried out to investigate almost equal color strength between wool component and cationized cotton component when wool/cationized cotton blends was dyed with acid dye/direct dye by the one bath two step method in a non-electrolytic and acidic dyebath.

  • PDF

Analysis and comparison of the 2D/1D and quasi-3D methods with the direct transport code SHARK

  • Zhao, Chen;Peng, Xingjie;Zhang, Hongbo;Zhao, Wenbo;Li, Qing;Chen, Zhang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • The 2D/1D method has become the mainstream of the direct transport calculation considering the balance of accuracy and efficiency. However, the 2D/1D method still suffers from stability issues. Recently, a quasi-3D method has been proposed with axial Legendre expansion. Analysis and comparison of the 2D/1D and quasi-3D method is conducted in theory from the equation derivation. Besides, the C5G7 benchmark, the KUCA benchmark and the macro BEAVRS benchmark are calculated to verify the theory comparisons of these two methods with the direct transport code SHARK. All results show that the quasi-3D method has better stability and accuracy than the 2D/1D method with worse efficiency and memory cost. It provides a new option for direct transport calculation with the quasi-3D method.

Correlation of egg counts of Clonorchis sinensis by three methods of fecal examination

  • CHOI Min-Ho;GE Tao;YUAN Shang;HONG Sung-Tae
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.3 s.135
    • /
    • pp.115-117
    • /
    • 2005
  • The Kato-Katz (KK) method is a well-known method of fecal examination for helminthiases. Its diagnostic sensitivity was found very high for clonorchiasis. The present study evaluated the correlation of Clonorchis sinensis egg counts by the KK method with those by direct smear and formalin-ether (FE) technique. The egg counts obtained by the KK method (Y) were correlated with the counts by direct smear (X) with the equation of Y = 659.4 + 0.266X ($r^2$ = 0.738), but not with those by the FE method. The present study demonstrated that the KK method and direct smear were useful for both qualitative and quantitative diagnosis of clonorchiasis, especially in the field.

High Performance Hybrid Direct-Iterative Solution Method for Large Scale Structural Analysis Problems

  • Kim, Min-Ki;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.79-86
    • /
    • 2008
  • High performance direct-iterative hybrid linear solver for large scale finite element problem is developed. Direct solution method is robust but difficult to parallelize, whereas iterative solution method is opposite for direct method. Therefore, combining two solution methods is desired to get both high performance parallel efficiency and numerical robustness for large scale structural analysis problems. Hybrid method mentioned in this paper is based on FETI-DP (Finite Element Tearing and Interconnecting-Dual Primal method) which has good parallel scalability and efficiency. It is suitable for fourth and second order finite element elliptic problems including structural analysis problems. We are using the hybrid concept of theses two solution method categories, combining the multifrontal solver into FETI-DP based iterative solver. Hybrid solver is implemented for our general structural analysis code, IPSAP.

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.

Direct position tracking method for non-circular signals with distributed passive arrays via first-order approximation

  • Jinke Cao;Xiaofei Zhang;Honghao Hao
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.421-431
    • /
    • 2024
  • In this study, a direct position tracking method for non-circular (NC) signals using distributed passive arrays is proposed. First, we calculate the initial positions of sources using a direct position determination (DPD) approach; next, we transform the tracking into a compensation problem. The offsets of the adjacent time positions are calculated using a first-order Taylor expansion. The fusion calculation of the noise subspace is performed according to the NC characteristics. Because the proposed method uses the signal information from the previous iteration, it can realize automatic data associations. Compared with traditional DPD and two-step localization methods, our novel process has lower computational complexity and provides higher accuracy. Moreover, its performance is better than that of the traditional tracking methods. Numerous simulation results support the superiority of our proposed method.

Improved Direct Power Control of Shunt Active Power Filter with Minimum Reactive Power Variation and Minimum Apparent Power Variation Approaches

  • Trivedi, Tapankumar;Jadeja, Rajendrasinh;Bhatt, Praghnesh
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1124-1136
    • /
    • 2017
  • Direct Power Control technique has become popular in the grid connected Voltage Source Converter (VSC) applications due to its simplicity, direct voltage vector selection and improved dynamic performance. In this paper, a direct method to determine the effect of voltage vector on the instantaneous active and reactive power variations is developed. An alternative Look Up Table is proposed which minimizes the commutations in the converter and results in minimum reactive power variation. The application of suggested table is established for Shunt Active Power Filter (SAPF) application. The Predictive Direct Power Control method, which minimizes apparent power variation, is further investigated to reduce commutations in converters. Both the methods are validated using 2 kVA laboratory prototype of Shunt Active Power Filters (SAPF).